MAURY USCG vessel records Sign in
← All vessels

A&B

A&B is a 2014 passenger vessel (inspected). The Coast Guard has recorded 21 inspections since 2014, most recently in July 2026, along with 8 deficiencies.

Records from 2014 to 2026. Most recent: inspection, 13 July 2026.

Built
2014
Last inspected
13 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH7393
1310980
Flag
UNITED STATES
367647690
Maury page id
psix-1310980

Inspections, by type

…with no type recorded4
Years with a record 13 calendar years (2014–2026)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)34.0 ft × 13.9 ft × 6.0 ft
Registered tonnagegross 18 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEA HAWK INDUSTRIES INC · SEBRING · built 2014
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNAPLES, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 May 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Gross Ton
15 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH7393MMSI 367647690 · active · compulsorily equipped · granted 28 August 2024, expires 20 November 2034
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

13 July 2026 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8437153
29 April 2025 Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8119932
15 July 2024 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7956714
24 April 2023 Annual Inspection · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7673021
12 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7575699
14 July 2022 Type not recorded
No type recorded · USCGC CROCODILE (WPB 87369) · USCG East District (CGD-E) · Activity 7516354
3 May 2022 DAPI Audit · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7440090
2 June 2021 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7212959
25 January 2021 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7128194
12 August 2020 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7029857
13 May 2019 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6680213
31 January 2019 Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6619491
17 August 2018 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6514155
18 October 2017 Type not recorded
No type recorded · Station Fort Myers Beach · USCG Southeast District (CGD-SE) · Activity 6290590
24 May 2017 Deficiency Check · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6152601
9 January 2017 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6062614
31 October 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6031219
2 July 2016 Type not recorded
No type recorded · Station Fort Myers Beach · USCG Southeast District (CGD-SE) · Activity 5927468
2 December 2015 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5764091
10 October 2015 Type not recorded
No type recorded · Station Fort Myers Beach · USCG Southeast District (CGD-SE) · Activity 5740612
20 August 2014 Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4960435

Deficiency record · 8

05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 2 June 2021 Resolved
EPIRB battery expired in January 2021 and the hydrostatic release unit expired May 2021. Vessel restricted to less than 03 nautical miles from shore until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 June 2021
Resolved 7 June 2021
Resolution: Received registration form for EPIRB and photos of newly installed HRU.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2019 Resolved
Vessel has gone past dry dock date, do not carry passengers until drydock is complete. (46CFR176.802)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 February 2019
Resolution: Completed dry dock.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 24 May 2017 Resolved
Fire extinguishers and Fireboy have not been serviced in the last year, do not carry passengers until serviced. 46 CFR 176.810(b)(1) and (2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2017
Resolution: Service was performed on all fire equipment. Proof of service was provided.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 2 December 2015 Resolved
Owner had an list of employees that did not match current members on staff. Provide updated list from drug consortium that match employees that are currently on staff. 46 CFR 16
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 2 December 2015
Resolution: Operator supplied a current updated copy from drug consortium with employees that currently work at A & B Charters.
Navigation › Piloting/Steering › Marine Charts
Issued 2 December 2015 Resolved
Owner cannot provide an updated chart, light list, & tide tables of area of operation. Provided current chart, light list, and tide tables of area of operation. 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 16 December 2015
Resolution: Owner provide proper/current chart, light list, and tide tables for area of operations.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 December 2015 Resolved
Ammonia inhalants in first aid kit are expired. Provide current ammonia inhalants for first aid kit. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 16 December 2015
Resolution: Owner provided current ammonia inhalants for first aid kit.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 2 December 2015 Resolved
Vessels vent covers for engine room do not fit properly. Repair or replace vent covers. 46 CFR 184.710
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 16 December 2015
Resolution: Vessel supplied proper size vent covers for engine room and showed proper operation. SAT
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 December 2015 Resolved
Owner does not have the COI and Stability Ltr posted in there proper locations, COI so passengers may see in common area and Stability Ltr posted at operator station. Post certificates in proper locations. 46 CFR 176.302
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 December 2015
Resolved 16 February 2016
Resolution: Owner posted certificates in properly locations.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.