MAURY USCG vessel records
← All vessels

HAMMONIA HUSUM

HAMMONIA HUSUM is a 2006 freight ship. The Coast Guard has recorded 7 inspections since 2016, most recently in September 2020, along with 2 deficiencies and 3 operational controls.

Records from 2016 to 2020. Most recent: inspection, 28 September 2020.

Built
2006
Last inspected
28 September 2020
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 September 2020
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9326835
1311103
Flag
LIBERIA
Maury page id
psix-1311103

Documentation record

Tonnage as PSIX records it26836 - Convention (Subpart B), Gross Ton
12743 - Convention (Subpart B), Net Ton
34254 - Dead Weight, Ton
45747 - Displacement, Ton
26836 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 7

28 September 2020 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7065605
9 May 2019 Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6680485
30 April 2019 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6673172
14 May 2018 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6413798
30 March 2018 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6381930
21 February 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6357465
14 June 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5906771

Deficiency record · 2

09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 30 April 2019 Resolved
Cylinders must always be secured and when not in use, they must be stowed in a rack in an upright position with the valve protection cap in place. Oxygen and acetlyene bottles in the lockers are not secured in racks. 46 CFR 147.60 (b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 9 May 2019
Resolution: All oxygen and acetylene bottles have been stored in racks in upright position with caps and respective stores.
Electrical › Electric Generation Source (emergency) › Generator
Issued 21 February 2018 Resolved
Oil fuel pipes, if damaged, would allow oil to escape from a tank having a capacity of 500L and above shall be fitted with a valve dirrectly on the tank capable of being closed from a safe position outside the space. The shutoof mechanism to the fuel shut off in the emergency generator space would not activate form outside the space. SOLAS 04 II-2/4.2.2.3.4
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 March 2018
Resolution: Send video of proper opertion of emergancy fuel shutoff switch from outside the emergency generator space.

Ownership record