← All vessels
PAN TOPAZ
PAN TOPAZ is a 2012 freight ship. The Coast Guard has recorded 10 inspections since 2015, most recently in January 2023, along with 3 deficiencies and 1 operational control.
Records from 2015 to 2023. Most recent: inspection, 27 January 2023.
- Built
- 2012
- Last inspected
- 27 January 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 3 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9625827 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FMZ5
1312431
Flag
PANAMA
—
Maury page id
psix-1312431
Inspections, by type
…with no type recorded2
Years with a record
8 calendar years (2015–2023)
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it45055 - Convention (Subpart B), Gross Ton
26973 - Convention (Subpart B), Net Ton
82783 - Dead Weight, Metric Ton
96524 - Displacement, Metric Ton
26973 - Convention (Subpart B), Net Ton
82783 - Dead Weight, Metric Ton
96524 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 10
27 January 2023
PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7627879
6 July 2021
PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7236383
28 January 2020
Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6897698
23 November 2019
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6856338
25 September 2019
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6807753
13 September 2019
Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6810636
6 June 2018
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6428866
9 April 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6114427
25 January 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5801090
4 August 2015
Deficiency Check · Administrative Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 5205753
Deficiency record · 3
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 6 June 2018
Resolved
1720 - PRIOR TO TRANSFERRING OIL OR HAZMAT TO OR FROM A VESSEL IN U.S.WATERS, WACH TRANSFER PIPE SYSTEM MUST BE TESTED UNDER STATIC LIQUID PRESSURE AT LEAST 1.5 TIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE ANNUALLY. LAST TRANSFER PIPE SYSTEM PRESSURE TEST WAS ONLY TESTED AT WORKING PRESSURE, NOT AT 1.5 TIMES. PROVIDE PROOF OF PROPER TEST PRIOR TO TRANSFERRING IN U.S. 33 CFR 156.170 C
Operations/Management › Ballast Water Managment › Submission of Report
Issued 6 June 2018
Resolved
9900 - UNLESS OPERATING EXCLUSIVELY ON VOYAGES BETWEEN PORTS OR PLACES WITHIN A SINGLE COTP ZONE, THE MASTER, OWNER, OPERATOR, AGENT, OR PERSON IN CHARGE OF A VESSEL SUBJECT TO THIS SUBPART AND THIS SECTION MUST SUBMIT A BALLAST WATER REPORT TO THE NATIONAL BALLAST WATER CLEARINGHOUSE (NBIC) BY ELECTRONIC BALLAST WATER REPORT FORMAT USING METHODS SPECIFIED AT NBIC'S WEBSITE NO LATER THAN 6 HOURS AFTER ARRIVING AT THE PORT. MASTER COMPLETED BALLAST WATER REPORTING FORM BUT DID NOT SUBMIT TO NBIC. 33 CFR 151.2060 10C
Construction/Loadline › Hull › Hull Plating
Issued 25 January 2016
Resolved
1299- The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship in all respects will remain fit to proceed to sea without danger. There is a 1.5 meter by .5 meter indentation located on the starboard bow. 74SOLAS (14 cons) 1/11a Action taken- 16ac
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National