MAURY USCG vessel records
← All vessels

ALKIMOS HERACLES

ALKIMOS HERACLES is a 2014 freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in June 2026, along with 5 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 20 June 2026.

Built
2014
Last inspected
20 June 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 June 2026
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9668881
1312513
Flag
PANAMA
Maury page id
psix-1312513

Documentation record

Tonnage as PSIX records it81922 - Dead Weight, Metric Ton
43007 - Convention (Subpart B), Gross Ton
27490 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 8

20 June 2026 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8385970
13 August 2025 Polar Code Examination · PSC B
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8209334
18 March 2024 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7881087
1 January 2021 Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7118519
25 November 2019 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6856615
8 May 2019 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6679498
9 February 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6346970
31 May 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5888410

Deficiency record · 5

04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 13 August 2025 Resolved
Provided with suitable arrangements to ensure working access to steering gear machinery and controls. These arrangements shall include handrails and gratings or other non slip surfaces to ensure suitable working conditions in the event of hydraulic fluid leakage. Steering Gear room did not have non-slip surface. code 04106 74 SOLAS 2024 cons ch II-I Reg 29 13.2 50BC
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 September 2025
Resolved 16 August 2025
Resolution: Vessel applied a non slip surface to the steering gear room prior to our departure. Deficiciency cleared onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 25 November 2019 Resolved
The emergency generator shall be capable of providing power for a period of at least 18 hours. The instructions next to the fuel tank state that at least 600 liters of fuel shall be maintained. Upon inspection of the fuel tank level, it was discovered that the tank guage was inoperable and manually sounding the tank showed there was only 525 liters of fuel. Based on the generator's fuel consumption rate, only 510 liters of fuel is required to run the generator for 18 hours. 74 SOLAS (2014) CH. II-I, Reg. 43
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 25 November 2019
Resolution: Crew was able to add 100 liters of fuel to the tank, giving a total of 625 liters which satisfies the placarding requirement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2019 Resolved
Operators in charge of a vessel equipped with ballast tanks that operate within the waters of the U.S. must install and operate a ballast water management system that is Coast Guard approved. While taking on ballast water through the Coast Guard approved ballast water treatment system in Zhoushan, China, it was found inoperable. The vessel proceeded to conduct an offshore ballast water exchange, however the ballast water was not treated through the Coast Guard approved system before entering U.S. waters. 33 CFR 151.2025 (a)(1) 17 a.c.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 November 2019
Resolution: Received Class report attesting to proper operation of the BWTS.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 November 2019 Resolved
If the installed ballast water management system stops operating properly during a voyage, the person directing the movement of the vessel must ensure that the problem is reported to the nearest COTP as soon as practicable. The vessel became aware of inoperable ballast water treatment system on 01NOV19 and the notification to the COTP for inoperative BWTS was not made until 23NOV19. 33 CFR 151.2040 (b)
Action required: 10 - Deficiency Rectified
Resolved 25 November 2019
Resolution: Provided guidance to Master about BWMS reporting requirements.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 9 February 2018 Resolved
Means shall be provided to control leaks of flammable liquids. PSCO observed oil accumulation several inches deep below the deck plates near the M/E main filter. Chief Engineer was able to recify on the spot. 74SOLAS14 II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 February 2018
Resolved 9 February 2018
Resolution: Recified before the end of exam.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.