Records from 2020 to 2021. Most recent: inspection, 13 September 2021.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 13 September 2021
No resolution recorded
The International Load Line Certificate shall not be delivered to the ship until the officer or surveyor... has certified that the marks are correctly and permanently indicated on the ship's sides... load line observed on hull does not match their issued certificate. ICLL(88) Annex I/ Reg. 9. 50ac.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2021 — due date passed with no resolution recorded
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 September 2021
No resolution recorded
The master, owner, operator, agent, or person in charge of a vessel... must ensure the maintenance of written or digital records that include the information required to be reported by 33 CFR 151.2070 of this subpart... PSCO's discovered the ballast water management logbook was missing entries after 17AUG21. Additionally, NBIC submissions for 09SEP21 and 13SEP21 contained quantities that did not match the recorded logbook values. 33 CFR 151.2070(a). 50c.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2021 — due date passed with no resolution recorded
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil and oily mixtures from machinery spaces
Issued 31 August 2020
Resolved
PSCO witnessed excessive oil in bilges, machinery and piping around the engine room. Additionally, 4 flexible hoses were found to be draining into the #3 HFO overflow tank. The tank is not listed on the IOPP supplement as means of retaining and disposing oil residues. MARPOL Annex 1 Reg 6.4.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2020
Resolution: Received email with documentation from Flag/Class (attached in documents)
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 31 August 2020
Resolved
PSCO found serveral unapproved modifications in the engine room including (02) washing machine connectied directly to the MSD. 74Solas(2001) CH.1 Reg 1-11(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 September 2020
Resolution: Received email with documentation from Flag/Class (attached in documents)
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 31 August 2020
Resolved
PSCO witnessed serveral pipes exposed due to worn out lagging. 74SOLAS(2001) II-1/26.1
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 September 2020
Resolved 17 January 2021
Resolution: Completed a satisfactory exam
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 31 August 2020
Resolved
PSCO witnessed an unsatifoactory test of the Oily water seperator due to lack of crew familiarization. Marpol Annex 1 Reg. 11.1
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 September 2020
Resolution: Received email with documentation from Flag/Class (attached in documents)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 August 2020
Resolved
PSCO witnessed improper terminal ends.
74Solas(2001) Ch II-1/45.1.3
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 September 2020
Resolution: completed a satisfactory exam