Records from 2017 to 2021. Most recent: inspection, 9 February 2021.
Inspection history · 5
9 February 2021
PSC B · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7137616
17 June 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6979482
5 June 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6968922
4 June 2019
PII Safety Exam · ISPS II Exam · Administrative Inspection · Deficiency Check · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6700121
1 April 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6107425
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 February 2021
No resolution recorded
The machinery, boiler, other pressure vessel and associated piping and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed a steady drip of water form teh water pipe supplying the No.2 main F/O heater.
74 SOLAS (20) 11-1/26.1
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 9 February 2021
No resolution recorded
Ship shall be provided with arrangements equipment and fittings of sufficient safe working load to enable the safe conduct of all towing and mooring operations associated with the normal operation of the ship. PSCO observed multiple frays on the head and spring moorning lines.
74 SOLAS (20) 11-1/3-8.2
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 February 2021
Resolved
Muster and embarkation stations shall be adequately illuminated by lighting supplied from the emergency source of electrical power. PSCO observed 01 Broken emergency lights in the vicinity of the emergency muster station.
74 SOLAS (20)111/11.4
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 9 February 2021
Resolution: Ship's crew replaced bulb in broken emergency light.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 4 June 2019
Resolved
07111 - PERSONAL EQUIPMENT SHALL CONSIST OF PROTECTIVE CLOTHING OF MATERIAL TO PROTECT THE SKIN FROM HEAT RADIATING FROM THE FIRE AND FROM BURNS AND SCALDING BY STEAM. PSCO OBSERVED DURING FIRE DRILL, 04 FIRE FIGHTERS OUTFIT'S PROTECTIVE SHELL COMPLETELY WORN DEFYING PROTECTIVE PURPOSE.
74SOLAS (2014) II-2/10.10.1.1
FSS CH.3.2.1.1.1
ACTION CODE: 17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 June 2019
Resolution: Vessel received four sets of approved Firemen's Heat Protective Clothing.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 4 June 2019
Resolved
07101 - LOCKERS AND STORE ROOMS NOT HAVING PROVISIONS FOR THE STORAGE OF FLAMMABLE LIQUIDS SHALL MEET THE REQUIREMENTS OF THE REGULATION. PSCO OBSERVED LARGE AMOUNT OF PRESURIZED FLAMMABLE BOTTLES AND ACID BATTERIES IN A STORE ROOM WITHIN ACCOMODATION.
74SOLAS(2014)II-2/9.2.3.3.2
ACTION CODE: 10c
Action required: 10 - Deficiency Rectified
Resolved 4 June 2019
Resolution: Store room was cleaned out of all flammable materials and batteries.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboat inventory
Issued 4 June 2019
Resolved
11102 - ONE OR MORE TOTALLY ENCLOSED LIFEBOATS COMLYING WITH THE REQUIREMENTS OF THE CODE WILL ACCOMODATE THE TOTAL NUMBER OF PERSONS ON BOARD. THE LIFEBOAT SHALL HAVE ANTI-SEASICKNESS MEDICINE SUFFICIENT FOR AT LEAST 48 HOURS AND ONE SEASICKNESS BAG FOR EACH PERSON. PSCO OBSERVED INSUFFICIENT AMOUNT OF ANTI-SEASICKNESS PILLS IN THE LIFEBOAT.
74SOLAS(2014)III/31.1.1.1
LSA 4.4.8.21
ACTION CODE: 16ac
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 June 2019
Resolution: Vessel received two 100 tablet bottles of anti-seasickness pills and 25 seasickness bags.
Lifesaving › Inflatable Liferafts › Markings
Issued 1 April 2017
Resolved
0620-INFLATABLE LIFERAFTS: ALL LIFESAVING APPLIANCES SHALL COMPLY WITH THE LIFE-SAVING APPLIANCES CODE WHICH REQUIRES INFLATABLE LIFERAFTS TO BE MARKED WITH SPECIFIC IDENTIFYING INFORMATION. ALL THREE INFLATABLE LIFERAFTS ARE MISSING THE FOLLOWING REQUIRED INFORMATION: SERIAL #, DATE WHEN LAST SERVICED, # OF PERSONS PERMITTED TO CARRY. 74SOLAS(14)III/34 LSA IV/4.2.6.3 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 1 April 2017
Resolved 6 April 2017
Resolution: Cleared deficiency with proper documentation verification. See documentation.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 1 April 2017
Resolved
0199-OTHER(CERTIFICATE): NON-TANK VESSELS OVER 400GT ARE REQUIRED TO HAVE A VESSEL RESPONSE PLAN THAT IDENTIFIES A LIST OF CONTACTS AND A GEOGRAPHIC SPECIFIC APPENDIX FO REACH COTP ZONE IN WHICH IT OPERATES. THE NTVRP DOES NOT HAVE A LIST OF CONTACTS OR GEOGRAPHIC SPECIFIC APPENDIX FOR ANY COTP ZONE, INCLUDING THE COTP IN WHICH THE VESSEL IS CURRENTLY OPERATING. 33CFR155.5030(c)(5) and (c)(9) 10c
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 1 April 2017
Resolved 1 April 2017
Resolution: MSU INSPECTORS OBSERVED VGP PROPERLY UPDATED.