GYPSY SPIRIT

GYPSY SPIRIT is a 1974 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1988, most recently in June 2026, along with 74 deficiencies.

Records from 1988 to 2026. Most recent: inspection, 3 June 2026.

Built
1974
Last inspected
3 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ5236
131678
Flag
UNITED STATES
367785670
Maury page id
psix-131678

Inspections, by type

…with no type recorded4
Years with a record 36 calendar years (1988–2026)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.0 ft × 17.2 ft × 8.5 ft
Registered tonnagegross 58 / net 47
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · HOLLAND, MI, UNITED STATES · built 1974
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 6 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
47 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ5236MMSI 367785670 · active · compulsorily equipped · granted 29 April 2017, expires 29 April 2027
WDD3757MMSI 367135850 · expired · compulsorily equipped · granted 22 August 2006, cancelled 22 October 2016
WUX5490MMSI not assigned · expired · compulsorily equipped · granted 11 June 1998, cancelled 25 October 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 65

3 June 2026 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8394697
27 May 2026 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8375587
23 December 2025 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8287977
28 July 2025 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8196913
14 July 2025 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8185441
13 May 2024 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7915595
1 April 2024 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7887892
1 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7678532
31 March 2023 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7659941
9 May 2022 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7446626
6 May 2021 DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7188559
18 December 2020 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7113619
9 September 2020 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7054607
29 April 2020 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6945546
7 June 2019 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6706780
31 May 2018 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6431229
13 July 2017 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6211575
29 June 2017 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6195739
20 May 2016 COI Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5882101
10 May 2016 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5948403
3 February 2016 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5808665
28 January 2016 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5805059
7 December 2015 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5776812
1 August 2014 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4943437
25 May 2012 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4321856
12 July 2011 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4079098
8 December 2010 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3906609
25 June 2008 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3248003
23 May 2008 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3189875
14 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3129942
14 June 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2961677
25 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2932418
8 September 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2775274
7 June 2006 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2673018
28 November 2005 Hull Examination
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2541884
15 September 2005 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2493306
21 July 2005 Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2427653
14 June 2004 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2099117
12 June 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1815581
24 June 2002 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1630541
26 July 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 770226
25 July 2001 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 191925
24 May 2001 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1464388
15 March 2001 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1427983
24 January 2001 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1056839
9 June 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1469970
26 April 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1438851
9 February 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1451417
22 January 1999 Hull Examination · Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1444103
21 September 1998 Hull Examination · Drydock Extension
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1400842
1 May 1998 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1423036
29 April 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1424448
10 July 1996 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1467480
18 October 1995 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1191177
30 August 1995 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 882983
16 June 1995 COI Inspection · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1450995
23 May 1994 Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 863306
23 May 1994 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1423938
7 September 1993 Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1142514
16 June 1993 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1155809
18 June 1992 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1260091
22 May 1991 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 934228
22 May 1991 Administrative
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 934384
31 May 1990 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 922671
14 June 1988 Hull Examination · Initial Certification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1030952

Deficiency record · 74

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2026 Resolved
The Master of a vessel shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessels normal berthing location or with a representative of the owner of the vessel. There is no established procedure for maintaining passenger count ashore.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 June 2026
Resolution: Master will provide passenger count to [name withheld] [phone withheld].
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 27 May 2026 Resolved
Each vessel must be equipped with a public address system. The vessel's PA system is not operational and public announcements made from the operating station during normal operating conditions cannot be heard without amplification. Prove proper operation of the installed PA system.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 June 2026
Resolution: Witnessed proper operation of PA system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 May 2026 Resolved
Before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made information passengers of the information in 46 CFR 185.506(a)(1)-(6). The safety orientation provided did not cover the required topics.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 June 2026
Resolution: Witnessed written passenger safety orientation covering required topics.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 27 May 2026 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. The mounting arrangement (velcro) for the machinery vent closures on the exterior of the vessel are painted over.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 June 2026
Resolution: Witnessed replacement of velcro fastening on hull and vent closures.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 May 2026 Resolved
Shutoff valves must be fitted in the fuel supply lines one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. There is no shutoff valve at the engine end of the starboard main engine fuel line.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 June 2026
Resolution: Witnessed satisfactory operation and installation of fuel shutoff valve at starboard main.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 May 2026 Resolved
Shutoff valves must be fitted in the fuel supply lines one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. There is no shutoff valve at the engine end of the port and starboard main generators.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 1 June 2026
Resolution: Witnessed satisfactory operation and installation of fuel shutoff valve at generators.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 May 2026 Resolved
On or before March 11, 1999, an existing vessel must comply with the bilge high level alarm requirements in 46 CFR 182.530. A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. None of the electric submersible automatic bilge pumps are provided with indicating lights at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 June 2026
Resolved 5 June 2026
Resolution: Owner provided photographic evidence of installation and operation.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 May 2026 Resolved
All pyrotechnic distress signals shall be stowed in a portable watertight container. The provided container is not of adequate size to hold all of the distress signals.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2026
Resolved 5 June 2026
Resolution: Owner provided photographic evidence of distress signal box.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 27 May 2026 Resolved
A vessel must carry either a first aid-kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents. The first aid kit may be considered acceptable if in meets all of the requirements of ISO 18813:2006(E).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2026
Resolved 5 June 2026
Resolution: Owner provided photographic evidence of new first aid kit on board vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 May 2026 Resolved
Each fire extinguisher on a vessel must be of an approved type. The fire extinguisher bracket provided for the 40 B:C fire bracket is not the bracket required to retain approval.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2026
Resolved 3 June 2026
Resolution: Owner provide photographic evidence of installation of proper fire extinguisher brackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2026 Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visual to the crew and passengers. There are no donning placards posted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2026
Resolved 1 June 2026
Resolution: Witnessed posting of placards.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers and crew from electrical hazards. The wiring for the hot water heater penetration at the tank is missing the support.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2026
Resolved 1 June 2026
Resolution: Witnessed satisfactory installation of the same.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2026 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Marine Inspectors condemned (1) adult life jacket. Replace the same. Vessel is restricted to the carriage of 48 passengers until complete.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2026
Resolved 1 June 2026
Resolution: Witnessed replacement lifejacket.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 27 May 2026 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date Coast Pilot and Light List. The vessel is not provided with up-to-date publications.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 June 2026
Resolved 3 June 2026
Resolution: Owner provide photographic evidence of required publications.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 27 May 2026 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 21 August 2026
Resolution: [name withheld] is no longer employed by the company.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 July 2025 Resolved
An adult life jacket must be carried for each person carried on board a vessel. Vessel has two lie jackets that are not servicable. Vessel is restricted to 54 passengers until new life jackets procured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2025
Resolved 28 July 2025
Resolution: Vessel has two new approved life jackets and can carry max passengers as stated on COI.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 14 July 2025 Resolved
As appropriate for intended voyage, a vessel must carry adequate and up-to-date: chart, coast pilot, and light list. These charts and pubs are out dated on vessel, procure new.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2025
Resolved 28 July 2025
Resolution: Vessel has procured current charts/pubs for intended voyages.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 April 2024 Resolved
Flexible or portable cords cannot be used for permanently installed wiring. The battery chargers in the port and starboard engine compartments are installed using extension cords. Remove extension cords and hardwire or plug directly in to an outlet using marine cable.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 May 2024
Resolved 13 April 2024
Resolution: Vessel provided photgraphic evidence of removal of extension cord and installation of outlet.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 March 2023 Resolved
INSTALLED CO2 SYSTEM TEMP SWITCHES APPEAR TO BE OVERHEATED. PROVIDE MANUFACTURER TESTING PROCEDURES FOR TESTING THE TEMP SWITCHES. REPLACE CURRENT TEMP SWITCHES THAT WERE SUBJECT TO FLAME.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 15 May 2023
Resolution: Vender installed 2 new HADS
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 31 March 2023 Resolved
PROVIDE TWO (2) INDIVIDUAL BATTERY SMOKE DETECTORS FOR FWD AND AFT CABINS.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 1 May 2023
Resolution: Owner/Master provided statement all detectors where replaced with models with 10 year battery. Cleared requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 March 2023 Resolved
PORT ENGINE MUFFLER HAS A CRACK/RUPTURE ON THE BOTTOM AND IS LEAKING WET EXHAUST SYSTEM WATER INTO THE VESSEL. MAKE REPAIRS TO MUFFLER AND STOP WATER INTRUSION.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 1 May 2023
Resolution: Owner repaired muffler and provided video of repairs.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 May 2022 Resolved
The vessel's first aid kit has expired items (ammonia inhalants). Replace expired items and ensure first aid kit contains all items to ensure equivalence with a first aid kit approved under 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2022
Resolved 18 May 2022
Resolution: Expired items were replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 September 2020 Resolved
Passenger count reduced for children down to 05 children due to one jacket being OOC. 46 CFR 180.25-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 September 2020
Resolution: One new childs lifejacket was placed into service.
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 9 September 2020 Resolved
Crew ladder to swim platform is missing rung causing unsafe condition. 46 CFR 177.15
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 May 2021
Resolution: Ladder rung was replaced with in-kind rung
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2020 Resolved
Ring buoy life line is deteriorating and needs to be replaced. 46 CFR 180.30-1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 September 2020
Resolution: Ring buoy replaced with new and stenciled properly.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 September 2020 Resolved
First aid kit medicine is expired as well as eye wash solution. Replace with new. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 21 September 2020
Resolution: New items placed into service.
Documentation › Markings/Placards › Capacity Marking
Issued 31 May 2018 Resolved
Add Draft Marks to vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2018
Resolved 21 August 2018
Resolution: Error in issuing the CG-835
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 29 June 2017 Resolved
replace expired items
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 13 July 2017
Resolution: Updated All expired items
Navigation › Piloting/Steering › Marine Charts
Issued 29 June 2017 Resolved
Update Nav Chart. current chart is from 2013.
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 13 July 2017
Resolution: New chart was purchased
Lifesaving › Hand Flares › Quantity
Issued 29 June 2017 Resolved
Provide proper amount of day/night flares
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 13 July 2017
Resolution: 6 days/orange smoke flares were purchased
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 9 June 2016 Resolved
Mark 26 Adult Lifejackets with Type I retro-reflective material. 46 CFR 185.604(h)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 10 June 2016
Resolution: 26 lifejackets marked as required.
Navigation › Piloting/Steering › Marine Charts
Issued 9 June 2016 Resolved
Update navigational charts. 46 CFR 184.420(a)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 19 July 2016
Electrical › Lighting (service) › Outlet Box
Issued 9 June 2016 Resolved
Correct polarity of electrical outlet in galley. 46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 10 June 2016
Resolution: Electrical outlet repaired and tested by Marine Inspector.
Navigation › Piloting/Steering › US Coast Pilot
Issued 9 June 2016 Resolved
Ensure 2016 Coast Pilot Onboard 46 CFR 184.420
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 9 July 2016
Resolved 19 July 2016
Engineering › Fuel Oil Service System › Hose
Issued 23 May 2008 Resolved
Properly replace or remove air hose that is being used as a fuel hose. It is the fuel cross over line.
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 23 May 2008
Resolution: O/O removed the hose.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 May 2008 Resolved
Properly replace & mark 4 child life jackets for top deck. Vsl is restricted to 2 children (under 75 lbs) until cleared.
Action required: 705 - Other - as specified
Due 23 May 2008
Resolved 23 May 2008
Resolution: Purchased 4 new lifejackets, labelled them and properly stored them.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 23 May 2008 Resolved
Properly replace port MDE cooling water discharge hose with one hose. Presently hoses are clamped to each other.
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 23 May 2008
Resolution: Hoses removed and a properly sized hose was installed.
Engineering › Fuel Oil Service System › Filter
Issued 23 May 2008 Resolved
Install proper flame shield or proper metal housing for fuel filters. Coffee cans are not approved heat shields.
Action required: 705 - Other - as specified
Due 23 June 2008
Resolved 24 June 2008
Resolution: Proper flames shield were installed on the vessel.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 25 May 2007 Resolved
Provide adequate "emergency exit" sign on lower deck to show means of escape.
Action required: 705 - Other - as specified
Due 25 June 2007
Resolved 13 June 2007
Resolution: Photos provided showing installation of exit signs.
Lifesaving › Lifefloat › Retroreflective Material
Issued 25 May 2007 Resolved
Provide new retro-reflective tape on lifefloats.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2007
Resolved 13 June 2007
Resolution: Photos provided displaying new retro tape on all lifefloats.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 25 May 2007 Resolved
Provide new lifeline on ringbuoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2007
Resolved 13 June 2007
Resolution: Photos and receipts providing confirmation that new lifeline was installed on vessel.
Engineering › Fuel Oil Service System › Valve
Issued 25 May 2007 Resolved
Provide direction of closure for F/O emergency shutoff valve.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 June 2007
Resolved 13 June 2007
Resolution: Photos were provided showing proper installation of direction closure placards at the remote F/O shutoff valves.
Stability › Watertight Integrity › Deadlight Cover
Issued 7 June 2006 Resolved
Provide a plan proposal to install hinged dead covers on opening port lights in accordance with 46 CFR 177.13-1 and 171.119, old T and S regulations.
Action required: 705 - Other - as specified
Due 7 August 2006
Resolved 8 September 2006
Resolution: Dead covers installed as required and meet applicable regs.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 June 2006 Resolved
Properly terminate dead end wires in a junction box or remove dead end wire and properly connect improper connections underneath upper deck helm counsel, in accordance with 46 CFR 183.05-50 (old T regulations).
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 17 July 2006
Documentation › Certificates/Documents › FCC SSL
Issued 7 June 2006 Resolved
Provide on board a valid FCC station license and Great Lakes Agreement.
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 27 June 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 7 June 2006 Resolved
Provide a plan proposal to properly replace generator exhaust that is constructed of PVC piping in accordance with 46 CFR 182.20-20 (old T).
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 9 June 2006
Documentation › Certificates/Documents › FCC SSL
Issued 7 June 2006 Resolved
Provide on board a valid FCC station license.
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 17 July 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 21 July 2005 Resolved
Properly stow CO2 cylinders located in port machinery room.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 24 August 2005
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 21 July 2005 Resolved
Replace or provide proper waste receptacles in accordance with 46 CFR 177.405.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 24 August 2005
Documentation › Markings/Placards › Lifejacket Placard
Issued 21 July 2005 Resolved
Provide and post lifejacket donning placard in accordance with 46 CFR 185.516.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 24 August 2005
Resolution: Put onboard two new lifejackets, all sat.
Documentation › Certificates/Documents › Stability Letter
Issued 21 July 2005 Resolved
Post stability letter at the operating station in accordance with 46 CFR 176.306.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 24 August 2005
Engineering › Fuel Oil Service System › Valve
Issued 21 July 2005 Resolved
Provide a plan of proposal of remote fuel shutoffs, emergency valves must be easily accessible.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 24 August 2005
Resolution: Installed from the aft of the main deck flexible reach rod cable, all sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 July 2005 Resolved
Provide proof of operation of fixed fire extinguishing system in accordance with 46 CFR 176.810.
Action required: 705 - Other - as specified
Due 21 August 2005
Resolved 24 August 2005
Resolution: Witnessed proper operation of heat sensor and pull cable by servicing technician, all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 June 2004 Resolved
Provide steel supports for engine room wiring LEGACY COMPONENT DESC: Wiring
Due 14 July 2004
Resolved 8 July 2004
Resolution: sighted this date
Electrical › Electrical Distribution System (service) › Cable
Issued 14 June 2004 Resolved
Replace any non-boat cable installations with proper types and clean up installations.
Due 14 July 2004
Resolved 8 July 2004
Resolution: Sighted this date.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 14 June 2004 Resolved
Restock first aid kit
Due 14 July 2004
Resolved 14 July 2004
Resolution: Received Master''s affadavit and copy of invoice for new kits meeting 160.041
Engineering › Bilge Water Management System › Pump
Issued 14 June 2004 Resolved
Procure hand bilge pump
Due 14 July 2004
Resolved 8 July 2004
Resolution: Sighted this date.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 June 2004 Resolved
Procure up to date charts and publications
Due 14 July 2004
Resolved 8 July 2004
Resolution: Sighted this date.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 14 June 2004 Resolved
Bring DAPI program into compliance with requirements of 46 CFR 16.
Due 21 June 2004
Resolved 20 June 2004
Resolution: Received copy of course completion certificate. Scanned to documents section.
Stability › Unintentional Flooding › General
Issued 14 June 2004 Resolved
Repair leaks in deck below carpetting on port side outside pilothouse where rail was moved and new screwholes created. (old ones not properly filled in).
Due 14 July 2004
Resolved 8 July 2004
Resolution: Sighted this date.
Lifesaving
Issued 24 May 2001 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Construction/Loadline
Issued 15 March 2001 Resolved
PERMANENTLY HARD PIPE AC RAW WATER SEA CHEST VALVE TO THROUGH HULL SPOOL.
Condition: Unknown
Due 31 May 2001
Resolved 27 April 2001
Construction/Loadline
Issued 15 March 2001 Resolved
PROVIDE PROPOSAL FOR PERMANENT REPAIR OF 3/8" HOLE IN WAY OF JUST FWD OF STBD STABILIZER AT CHINE AND MAKE PERMANENT REPAIR TO SAME AFTER APPROVAL OF PROPOSAL BY OCMI. (REPAIR PROCEDURES TO BE AWS APPROVED).
Condition: Unknown
Due 31 May 2001
Resolved 25 May 2001
Construction/Loadline
Issued 15 March 2001 Resolved
INSTALL A POSITIVE SHUTOFF VALVE OR IN-LINE CHECK VALVE AT EACH OVERBOARD DISCHARGE PORT AS CLOSE AS PRACTICLE TO EACH THROUGH HULL SPOOL PIECE.
Condition: Unknown
Due 31 May 2001
Resolved 25 May 2001
Lifesaving
Issued 26 April 1999 Resolved
REPLACE 60' LINE ON RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Unknown
Issued 26 April 1999 Resolved
PROVIDE PROOF OF DRUG TESTING IAW 46 CFR PART 16._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Unknown
Issued 26 April 1999 Resolved
INSTALL POLLUTION PLACARDS IN ENGINEROOMS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Electrical
Issued 26 April 1999 Resolved
INSTALL MEANS TO AUTOMATICALLY ACTIVATE EMERGENCY LIGHTING UPON LOSS OF POWER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1999
Resolved 26 April 1999
Construction/Loadline
Issued 22 January 1999 Resolved
CROP AND RENEW 2 AREAS OF VESSEL HULL PLATE, 1 ON STARBOARD SIDE AT KEEL, 3' AFT OF BOW AND THE OTHER PORT SIDE AT KEEL, AMID SHIPS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 January 1999
Resolved 4 February 1999
Navigation
Issued 16 June 1995 Resolved
Provide current issues of Lake Michigan Light list, NAVRUL's and 46 CFR Part 166-199, Subchapter T.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Unknown
Issued 16 June 1995 Resolved
Provide copy of stability letter, stability test proceedure or perform USCGwitnessed stability test.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Engineering
Issued 16 June 1995 Resolved
Connect starboard fuel oil tank vent located in aft void.
Condition: Unknown
Due 16 June 1995
Resolved 16 June 1995
Navigation
Issued 23 May 1994 Resolved
Update charts and pubs per 46 CFR 185.20-35.
Condition: Unknown
Due 23 May 1994
Resolved 23 May 1994
Construction/Loadline
Issued 7 September 1993 Resolved
WASTED HULL BAFFLES FOR SSG RAW WATER INTAKES.
Condition: Unknown
Due 7 September 1993
Resolved 7 September 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.