Records from 2016 to 2026. Most recent: inspection, 21 January 2026.
Inspection history · 27
21 January 2026
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8299316
20 November 2025
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8271741
21 September 2025
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8239025
21 September 2025
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8241108
24 January 2025
Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8069527
5 September 2024
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7984872
6 February 2024
Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7861351
7 November 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7820911
26 October 2022
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7584259
8 February 2022
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7392435
28 October 2021
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7341142
29 July 2021
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 7272300
28 July 2021
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 7275239
21 September 2020
Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7062373
3 March 2020
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6919740
30 September 2019
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6818578
7 January 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6605488
18 October 2018
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6562093
9 January 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6340188
24 December 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6334178
23 December 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6328509
20 May 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6160060
17 January 2017
Annual Inspection · Deficiency Check · DAPI Audit · In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6071644
4 January 2017
Damage Survey · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6066163
3 January 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6073864
28 September 2016
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6012063
7 January 2016
DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5796872
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 21 September 2025
Resolved
46 CFR 176.840 The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are employed. Prove proper operation of the vessel's main engines to the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 September 2025
Resolution: Control box replaced. Sea Trials sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 September 2024
Resolved
Propulsion machinery must be suitable for the propulsion requirements of the hull in which it is installed and capable of operating at constant marine load. STBD propulsion engine is inoperable.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2024
Resolution: Fuel pump replaced. Operational test conducted.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 17 November 2022
Resolved
The shutoff valve at the tank must be manually operated from outside the compartment in which the valve is located. Starboard side emergency fuel shut off valve is inoperable from outside the space due to broken cable. Cable to be replaced and proper valve actuation to be proven prior to the carriage of passengers. 46 CFR 455(b)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 November 2022
Resolution: Cable replaced an valve operates as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 November 2022
Resolved
Each life float must be fitted with a light. Float light for life float not provided. Provide and attach approved type floating waterlight to the life float prior to operating at night. 46 CFR 180.175(d)
Action required: 705 - Other - as specified
Resolved 30 November 2022
Resolution: Float light provided and attached to life float.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 November 2022
Resolved
The master and crew of a vessel will be familiar with the content of an have mounted at the operating station , emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Emergency instructions not posted.
46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 December 2022
Resolved 30 November 2022
Resolution: Emergency instructions posted.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 3 November 2021
Resolved
EPIRB HRU expired. Replace HRU. Route restricted to no more then 3 miles from shore. 46 CFR 185.740
Action required: 705 - Other - as specified
Resolved 11 November 2021
Resolution: HRU replaced.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 29 October 2020
Resolved
Stbd side emergency fuel shut off valve does not close. Make repairs and prove proper operation of valve.
46 CFR 182.455
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 October 2020
Resolution: Repairs made SAT.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 September 2019
Resolved
46CFR182.530 (a) A vessel of 26 feet must be provided witha visual and audible alarm at the operating station to indicate high water in the spaces. Replace audible bilge alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2019
Resolution: Bilge alarm tested satisfactory
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 September 2019
Resolved
46CFR185.728 (b) The master shall ensure that the EPIRB battery is replaced IAW FCC regulationsin 47 CFR 80. Battery is expired and needs to be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2019
Resolution: New EPIRB installed
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 30 September 2019
Resolved
46CFR180.68 (a) A vessel on a limited coastwise route shall have 6 red handflare distress signals and 6 hand orange smoke distress signals. Vessel only had 4 not expired flares on board. Vessel needs 12.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 October 2019
Resolution: New flares on board
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 September 2019
Resolved
46CFR180.70 (b) (1)-Each lifering shall be approved IAW 160.050 (subchapter Q) and have retroreflective tape. Lifering has no retrorefelctive tape. Replace as needed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 October 2019
Resolution: Retrorefelctive tape added to life ring
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 January 2019
Resolved
Fuel shutoff valves inoperable at wheelhouse.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2019
Resolved 11 January 2019
Resolution: Test Port and Starboard F.O. shutoff valves. Operated satisfactorily.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 7 January 2019
Resolved
Engine interlock shutdown allows the engine to restart without system in over ride.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 January 2019
Resolved 11 January 2019
Resolution: Verified proper operation of engine shutdown via installed fire system.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 7 January 2019
Resolved
Hydrostatic Realease Unit port side life ring not marked with the required 2 year expiration date. Vessel restricted operations to less than 3 miles.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 January 2019
Resolved 18 January 2019
Resolution: Hydrostatic release was replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 January 2019
Resolved
Alcohol Test Strips expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 January 2019
Resolved 22 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 January 2019
Resolved
Life Ring Port Side deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2019
Resolved 11 January 2019
Resolution: Port side life ring replaced.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 7 January 2019
Resolved
Bilge high level alarm in forward compartment inoperable. No audible or visual indicators operating at wheelhouse.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 January 2019
Resolved 11 January 2019
Resolution: Verified satisfactory operation of high bilge level alarm in forward compartment.
Engineering › Sea-water System (primary cooling) › Piping
Issued 23 December 2017
Resolved
46 CFR 182.420: Replace port-side engine cooling systen impeller, conduct tests, and contact CG upon completion of reapirs.
Action required: 705 - Other - as specified
Resolved 25 December 2017
Resolution: Vessel replaced port side impeller and tested satisfactoriy.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 22 January 2017
Resolved
Vessel reported starboard engine casualty via black smoke emitting from engine. Vessel must demonstrate satisfactory operation of vessel's propulsion system prior to carrying passengers. 46CFR176.800
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 January 2017
Engineering › Fuel Oil Service System › Hose
Issued 17 January 2017
Resolved
Replace or make the SSDG F/O supply line available for inspection. 46CFR176.800
Due 20 January 2017
Resolved 23 January 2017
Operations/Management › Drills/Instruction › Fire
Issued 17 January 2017
Resolved
Provide updated training log. 46CFR185.520
Due 24 January 2017
Resolved 23 January 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 January 2017
Resolved
Show proper operation of nav lights prior to conducting night operations. COLREGS
Action required: 705 - Other - as specified
Resolved 27 January 2017
Operations/Management › Pollution › Control of Garbage
Issued 17 January 2017
Resolved
Provide garbage plan. 33CFR151.57
Due 24 January 2017
Resolved 23 January 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 January 2017
Resolved
Provide/replace first aid medications. 46CFR184.710
Action required: 705 - Other - as specified
Due 24 January 2017
Resolved 27 January 2017
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 17 January 2017
Resolved
Provide 02 portable lights. 46CFR183.430
Due 24 January 2017
Resolved 23 January 2017
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 January 2017
Resolved
Label adult/child life jackets. 46CFR180.130
Due 24 January 2017
Resolved 23 January 2017
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 January 2017
Resolved
Separate child and adult life jackets. 46CFR180.130
Due 24 January 2017
Resolved 23 January 2017
Engineering › Fuel Oil Service System › Hose
Issued 17 January 2017
Resolved
Chaff/protect all vital hoses. 46CFR176.800
Due 24 January 2017
Resolved 23 January 2017
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 17 January 2017
Resolved
Install port shaft bonding brush system. 46CFR183.370
Due 24 January 2017
Resolved 23 January 2017
Engineering › Steering Gear System › Rudder Stock
Issued 17 January 2017
Resolved
Connect port/stbd rudder post bonding wires. 46CFR183.370
Due 24 January 2017
Resolved 23 January 2017
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 4 January 2017
Resolved
Unknown reason for shaft seperating and vessel taking on water.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 January 2017
Resolution: New shaft was installed and test under load allsat.
Construction/Loadline › Hull › Hull Plating
Issued 28 September 2016
Resolved
3 areas of delamination on starboard side.
-Nitrox space aft
-Engine compartment forward behind fuel tank and around thru-hull
-lazerette aft corner
All delmainated areas need to be ground away to good fiberglass and re-glassed with original lay-up material.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 September 2016
Resolved 13 October 2016
Resolution: Areas of delamination were repaired.