MAURY USCG vessel records
← All vessels

TURSI-OPS

TURSI-OPS is a 2015 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in October 2025, along with 25 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 23 October 2025.

Built
2015
Last inspected
23 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 October 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH8046
1317190
Flag
UNITED STATES
Maury page id
psix-1317190

Documentation record

Registered dimensions (L × B × D)41.3 ft × 14.0 ft × 8.0 ft
Registered tonnagegross 30 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNAIAD INFLATABLES OF NEWPORT INC · PORTSMOUTH, RI, UNITED STATES · built 2015
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portMURRELLS INLET, SC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 August 2025 · expires 31 August 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Gross Ton
30 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

23 October 2025 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8251444
23 December 2024 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8051137
29 October 2024 Re-Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8026894
27 May 2024 Type not recorded
No type recorded · Station Georgetown · USCG Southeast District (CGD-SE) · Activity 7921302
23 October 2023 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7813123
14 October 2022 Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7577682
1 November 2021 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7341519
23 April 2021 Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7179301
31 March 2021 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7166831
28 October 2020 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7077685
9 January 2020 Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6883558
13 September 2019 Administrative Inspection · Damage Survey
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6814012
19 February 2019 Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6631737
29 January 2019 Administrative Inspection · Hull Examination · Drydock Exam · Internal Structural Exam · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6613893
24 April 2017 Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6113523
18 January 2017 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6319807
30 November 2016 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6045108

Deficiency record · 25

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 November 2021 Resolved
Vessel required to be equipped with portable fire extinguishers. Existing portable fire extinguisher IWO starboard console was found wasted/discharged.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 November 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 November 2021 Resolved
Vessel required to be equipped with power ventilation system. Existing power ventilation blower motor was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 11 November 2021
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 November 2021 Resolved
Vessel required to carry current/up to date marine charts for areas transited. Existing marine chart was expired/outdated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 November 2021
Resolved 11 November 2021
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 October 2020 Resolved
Vessels lifesaving equipment is required to be marked with retro-reflective material. Existing retro-reflective markings IWO life float were worn/faded/peeling.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2020
Resolved 31 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 October 2020 Resolved
Vessel required to be equipped with floating water lights. Existing floating water light for life float was inoperable due to corroded electrical terminals.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2020
Resolved 31 March 2021
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 28 October 2020 Resolved
Vessel required to be equipped with ventilation closure devices for spaces protected by fixed/pre-engineered fire extinguishing systems. Fuel tank void vent missing required ventilation closure device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2020
Resolved 31 March 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 28 October 2020 Resolved
Vessel's emergency escapes are required to be marked. Existing markings IWO port loading door was damaged/missing verbiage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 November 2020
Resolved 31 March 2021
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 January 2020 Resolved
EPIRB hydro-static release unit expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 4 March 2020
Resolution: Attending Inspector(s) verified installation of a new HRU.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 January 2020 Resolved
EPIRB regstration (NOAA) expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 4 March 2020
Resolution: Attending Inspector(s) verified registration renewal/decal placement on EPIRB.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 January 2020 Resolved
First aid kit was not suitable for service intended (expired items).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 4 March 2020
Resolution: Attending Inspector(s) verified renewal of expired items in first aid kit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 January 2020 Resolved
Proof of enrollment certificate for vessels crew was expired (12/31/2019).
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 4 March 2020
Resolution: Attending Inspector(s) verified status of consortium enrollment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 January 2020 Resolved
Floating water light batteries expired (>1 year service) for ring life buoy's.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 January 2020
Resolved 4 March 2020
Resolution: Attending Inspector(s) verified renewal of battery in floating water lights.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 January 2020 Resolved
VHF radio-telephone microphone required repair/replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2020
Resolved 4 March 2020
Resolution: Attending Inspector(s) verified VHF-FM radiotelephone microphone.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 September 2019 Resolved
Outer covering for inflatable collar system was torn IWO port bow.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 September 2019
Resolution: Attending Inspector(s) verified repairs made IWO bow covering (outer).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 January 2019 Resolved
Vessels portable fire extinguishers require annual servicing by a qualified servicing facility. Vessels portable fire extinguishers required annual servicing/testing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2019
Resolved 25 February 2019
Resolution: Attending Inspector(s) verified servicing of portable fire extinguishers.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 January 2019 Resolved
Portable fire extinguishers shall be installed to the satisfaction of the [name withheld] fire extinguisher bracket IWO starboard helm required replacement due to wastage.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 25 February 2019
Resolution: Attending Inspector verified installation of (new) portable fire extinguishing bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 29 January 2019 Resolved
Vessel required to provide/carry lifesaving equipment for 100% of the total number of persons on board (cold water) & 50% of the total number of persons on board (warm water). Vessels 22-person life float required replacement due to deterioration/beyond service life.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 7 March 2019
Resolution: Attending Inspector witnessed installation of (new) 22-man life float.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 January 2019 Resolved
Vessel required to be fitted with a flammable vapor detection system. Vessels visual/audible alarm located at the operators station (starboard/outboard) was inoperable/required replacement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 7 March 2019
Documentation › Markings/Placards › Warning Signs
Issued 18 January 2017 Resolved
Vessel's emergency escape(s) were not marked properly.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 February 2018
Resolved 12 February 2018
Resolution: Attending Inspector(s) verified installation of emergency escape markings.
Navigation › Piloting/Steering › Marine Charts
Issued 18 January 2017 Resolved
Vessel did not carry current/up to date marine charts for areas transited.
Action required: 705 - Other - as specified
Due 24 February 2018
Resolved 11 February 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date marine charts for areas transited.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 January 2017 Resolved
Vessel did not carry current/up to date navigational publications for areas transited.
Action required: 705 - Other - as specified
Due 24 February 2018
Resolved 11 February 2018
Resolution: Attending Inspector(s) verified carriage of current/up to date navigational publications for areas transited.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 18 January 2017 Resolved
Vessel's owner failed to provide a current proof of enrollment letter for consortium (current expiration 31DEC2017)
Action required: 705 - Other - as specified
Due 24 February 2018
Resolved 7 March 2018
Resolution: Attending Inspector(s) verified current proof of enrollment for consortium.
Navigation › Piloting/Steering › Marine Charts
Issued 30 November 2016 Resolved
Provide current/up to date marine navigational charts for areas transited.
Action required: 705 - Other - as specified
Due 29 December 2016
Resolved 24 April 2017
Resolution: Verified carriage of current/up to date marine charts of areas transited.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 30 November 2016 Resolved
Provide markings for PFD stowage (qty)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 December 2016
Resolved 24 April 2017
Resolution: Verified markings for PFD stowage.
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 November 2016 Resolved
Provide markings for emergency fuel shutoff valves (identification/operating instructions)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 December 2016
Resolved 24 April 2017
Resolution: Verified marking/labeling for emergency fuel shut-off valves.

Ownership record