MAURY USCG vessel records Sign in
← All vessels

MALAZGIRT

MALAZGIRT is a 2014 tank ship. The Coast Guard has recorded 15 inspections since 2016, most recently in May 2026, along with 1 deficiency and 1 operational control.

Records from 2016 to 2026. Most recent: inspection, 21 May 2026.

Built
2014
Last inspected
21 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9686728 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1317340
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1317340

Inspections, by type

…with no type recorded1
Years with a record 9 calendar years (2016–2026)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29875 - Convention (Subpart B), Gross Ton
29735 - Regulatory (Subpart C or D), Gross Ton
13834 - Convention (Subpart B), Net Ton
13834 - Regulatory (Subpart C or D), Net Ton
60770 - Displacement, Ton
49990 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

21 May 2026 Ballast Water Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8377828
27 April 2026 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8356268
16 July 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8187354
5 May 2025 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8123587
28 May 2023 PSC B · COC-CHEM Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7696949
4 February 2022 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7387603
25 July 2021 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7267146
9 March 2021 COC-CHEM Annual
Type not classified · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7150168
3 February 2020 COC-CHEM & TVE Renew
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6901875
1 September 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6529197
31 May 2018 ISPS II Exam · Ballast Water Examination · COE-Dockside · COC-CHEM & TVE Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6416074
30 August 2017 COE-Administrative
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6253673
7 July 2017 Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6200956
26 June 2017 COC-CHEM & TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6187388
27 April 2016 COC-CHEM & TVE Renew · ISPS II Exam · PII Safety Exam
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 5859892

Deficiency record · 1

Engineering › Fuel Oil Service System › Piping
Issued 26 June 2017 Resolved
The machinery shall be of a design and construction adequate for the service for which they are intended. Pressure switch of the fuel oil pressure deferential transmitter on the number two generator was leaking fuel into the engine room, rendering the number two generator inoperable. SOLAS 2014 II-I Reg 26.1 16(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2017
Resolved 28 June 2017
Resolution: Received Class report attesting to the proper repairs.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.