MAURY USCG vessel records
← All vessels

CORSAIR

CORSAIR is a 2014 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in April 2025, along with 3 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 9 April 2025.

Built
2014
Last inspected
9 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 April 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9689926
1318379
Flag
BAHAMAS, THE
Maury page id
psix-1318379

Documentation record

Tonnage as PSIX records it48060 - Convention (Subpart B), Gross Ton
73730 - Displacement, Metric Ton
54335 - Dead Weight, Metric Ton
18641 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

9 April 2025 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8102347
22 March 2024 COC-GAS Renew · PSC B · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7882810
19 August 2022 Administrative Inspection · COC-GAS Annual · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7534043
16 August 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7535593
16 August 2022 COE-Offshore
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7535614
15 June 2021 PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7224962
15 June 2021 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7241541
31 March 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7166477
26 May 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6961001
22 May 2020 PSC B · COC-GAS Annual · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6956479
1 May 2019 Ballast Water Examination · ISPS II Exam · COC-GAS Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6674364
19 April 2018 Deficiency Check · COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6389855
16 March 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6106309
14 March 2017 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6100428
14 March 2017 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 6223790
13 March 2016 Ballast Water Examination · COC-GAS Annual · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5825428

Deficiency record · 3

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 22 May 2020 Resolved
Electrical equipment, cables, and wiring should not be installed in hazardous locations unless it conforms with the standards not inferior to those acceptable to the organization. PSCO observed two lighting fixtures inside gas dangerous zone (one on the weather deck on aft side of dry powder room, port side, and one insdie compressor room, forward starboard side of #1 compressor skid) with shipping plugs installed vice certified safe cable terminations. Those two lights are to remain isolated until rectified. IGC Code (1993) 10.1.4
Condition: Damaged By Earlier Event
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 26 May 2020
Resolved 26 May 2020
Resolution: Class report was submitted attesting to replacement of lighting fixtures.
Personnel › Certificates/Documents/Licenses › License, Second Mate
Issued 19 April 2018 Resolved
The administration shall require that the company ensures that each seafarer assigned to any of its ships holds an appropriate certificate in accordance with the provisions of the Convention and as established by the Administration. The 2nd officer's certificate of competency has the limitation: "not valid for cargo vessel's". Provide clarification that the 2nd officer's certificate of competency is valid for assignment onboard liguified gas carriers. STCW (2011 Ed) I.14.1.1 Action taken: 40 bc
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 April 2018
Resolution: Received copy of new COC without cargo vessel limitations. Cleared deficiency.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 14 March 2017 Resolved
1160-Holds and Tanks - Gas detection equipment should be capable of sampling and analysing for each sample head location sequentially at intervals not exceeding 30 mins. Crew could not prove proper operation of gas detection. System never read more than 29% LEL when tested with span gas containing 50% LEL. IGC Code 13.6.8.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 16 March 2017
Resolution: Received class report attesting to repair and satisfactory operation of fixed gas detection system.

Ownership record