MAURY USCG vessel records
← All vessels

GAS RESPECT

GAS RESPECT is a 2014 tank ship. The Coast Guard has recorded 9 inspections since 2017, most recently in August 2024, along with 1 deficiency.

Records from 2017 to 2024. Most recent: inspection, 23 August 2024.

Built
2014
Last inspected
23 August 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 August 2024
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2017–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9698290
9V2516
1319355
Flag
SINGAPORE
Maury page id
psix-1319355

Documentation record

Tonnage as PSIX records it3591 - Convention (Subpart B), Gross Ton
3719 - Dead Weight, Metric Ton
6233 - Displacement, Metric Ton
1078 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

23 August 2024 COC-GAS Annual · Administrative Inspection · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7987419
31 July 2024 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7975306
19 August 2023 PSC B · COC-GAS Renew
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7771140
8 July 2022 COC-GAS Annual · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 7496906
1 July 2021 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7240201
7 January 2020 Ballast Water Examination · COC-GAS Annual · ISPS Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6881562
10 January 2019 COC-GAS Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6604480
8 January 2018 COC-GAS Annual · Deficiency Check · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6333895
10 January 2017 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6065671

Deficiency record · 1

Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 8 January 2018 Resolved
For the spaces listed in 13.6.7, alarms should be activated for flammable products when the vapor concentration reaches 30% of the lower flammable limit. Vessel’s fixed gas detection systems alarm found to be inoperable. Vessel restricted from conducting cargo operations in US waters until above deficiency is corrected and COC is completed. SOLAS 74 VII/13 & IGC 13.6.10 - 40a,b,c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 January 2018
Resolution: Successfully tested fixed gas detection system and alarm.