MAURY USCG vessel records
← All vessels

WL UGLICH

WL UGLICH is a 2014 freight ship. The Coast Guard has recorded 10 inspections since 2017, most recently in March 2026, along with 8 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 9 March 2026.

Built
2014
Last inspected
9 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9674373
1320398
Flag
HONG KONG
Maury page id
psix-1320398

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded1
Years with a record 4 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it24199 - Convention (Subpart B), Gross Ton
37728 - Dead Weight, Metric Ton
47837 - Displacement, Metric Ton
12794 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

9 March 2026 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8320583
9 March 2026 Explosive Handling Operation-Commercial
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8322858
8 March 2026 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8322928
17 November 2025 Explosive Handling Operation-Commercial
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8269767
18 August 2025 PSC B · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8209180
16 August 2025 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8211115
12 August 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8208502
7 August 2025 Administrative Inspection · VRP Review
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8204631
8 January 2018 Ballast Water Examination · COE-Dockside · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6330060
18 January 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6068597

Deficiency record · 8

11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 9 March 2026 Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in good working order and ready for immediate use. PSCO observed fuel in the bilge of the free fall lifeboat. SOLAS (2020) III/20.2, 17C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2026
Resolved 9 March 2026
Resolution: Issue was corrected on the spot
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2026 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured. PSCO observed improper installation of electrical terminals on battery terminal number 2. SOLAS (2020) II-1/40.1.3, 16AC
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2026
Resolved 13 March 2026
Resolution: Electrician replaced terminal with the proper installation.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 9 March 2026 Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. The company should ensure that all personnel involved in the company’s Safety Management System have an adequate understanding of relevant rules, regulations, codes, and guidelines. Vessel unable to provide procedures for voyage data recorder retrieval. Third Officer not trained in procedures for retrieval. Recommend external ISM audit regarding creation of procedures for retrieving data from the VDR. SOLAS (2020) IX/3.1 ISM Code 6.4, 50ABC
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2026
Resolved 13 March 2026
Resolution: VDR procedures were included in the SMS procedures and training was provided to the crew following an external ISM audit.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 August 2025 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed waterspraying from emergency fire pump during operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2025
Resolution: The emergency fire pump mechanical seal was repaired by the crew. BV and PSCO attended vessel and verified rectification.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 8 January 2018 Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Portable extinguishers which have been discharged shall be immediately recharged or replaced with an equivalent unit. Numerous portable extinguishers on deck are not fully charged and are severely deteriorated, with dry rotted and cracked hoses.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2018
Resolution: Received, reviewed and accepted class report confirming deficiency has been rectified.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 8 January 2018 Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. All portable extinguishers on board do not have a monthly maintenance tag on the, which is required according to the ships "Ship Safety & Training Record Book, Section 3-Periodic Checks."
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2018
Resolution: Received, reviewed and accepted class report confirming deciciency has been rectified.
Operations/Management › Ballast Water Managment › Alternative Management Method
Issued 8 January 2018 Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. The ships crew are currently conducting modifications to the Alternate Management System for the Ballast Water Management System, and stated they did not plan on having Flag State or class society attest and approve the modifications.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2018
Resolution: Received, reviewed and accepted class report confirming deficiency has been rectified.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pump Power Supply
Issued 18 January 2017 Resolved
01 0720 Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. The tyco seaplus water mist system was found by the PSCO to be in the "manual" position. 74SOLAS II-2 14.1.1 10c
Action required: 705 - Other - as specified
Resolved 18 January 2017
Resolution: System was switched to "automatic" mode.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.