Records from 2017 to 2026. Most recent: inspection, 9 March 2026.
Inspection history · 10
9 March 2026
PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8320583
9 March 2026
Explosive Handling Operation-Commercial
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8322858
8 March 2026
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8322928
17 November 2025
Explosive Handling Operation-Commercial
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8269767
18 August 2025
PSC B · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8209180
16 August 2025
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8211115
12 August 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8208502
7 August 2025
Administrative Inspection · VRP Review
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8204631
8 January 2018
Ballast Water Examination · COE-Dockside · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6330060
18 January 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6068597
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 9 March 2026
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in good working order and ready for immediate use. PSCO observed fuel in the bilge of the free fall lifeboat. SOLAS (2020) III/20.2, 17C
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2026
Resolved 9 March 2026
Resolution: Issue was corrected on the spot
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2026
Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards shall be ensured. PSCO observed improper installation of electrical terminals on battery terminal number 2. SOLAS (2020) II-1/40.1.3, 16AC
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2026
Resolved 13 March 2026
Resolution: Electrician replaced terminal with the proper installation.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 9 March 2026
Resolved
The company and the ship shall comply with the requirements of the International Safety Management Code. The company should ensure that all personnel involved in the company’s Safety Management System have an adequate understanding of relevant rules, regulations, codes, and guidelines. Vessel unable to provide procedures for voyage data recorder retrieval. Third Officer not trained in procedures for retrieval. Recommend external ISM audit regarding creation of procedures for retrieving data from the VDR. SOLAS (2020) IX/3.1 ISM Code 6.4, 50ABC
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2026
Resolved 13 March 2026
Resolution: VDR procedures were included in the SMS procedures and training was provided to the crew following an external ISM audit.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 August 2025
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use.
PSCO observed waterspraying from emergency fire pump during operation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 August 2025
Resolution: The emergency fire pump mechanical seal was repaired by the crew. BV and PSCO attended vessel and verified rectification.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 8 January 2018
Resolved
Fire-fighting systems and appliances shall be kept in good working order and readily available for immediate use. Portable extinguishers which have been discharged shall be immediately recharged or replaced with an equivalent unit. Numerous portable extinguishers on deck are not fully charged and are severely deteriorated, with dry rotted and cracked hoses.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2018
Resolution: Received, reviewed and accepted class report confirming deficiency has been rectified.
Fire Fighting › Portable CO2 Fire Extinguisher › Marking
Issued 8 January 2018
Resolved
Maintenance, testing and inspections shall be carried out based on the guidelines developed by the Organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. All portable extinguishers on board do not have a monthly maintenance tag on the, which is required according to the ships "Ship Safety & Training Record Book, Section 3-Periodic Checks."
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2018
Resolution: Received, reviewed and accepted class report confirming deciciency has been rectified.
Operations/Management › Ballast Water Managment › Alternative Management Method
Issued 8 January 2018
Resolved
After any survey of the ship under regulations 7, 8, 9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without the sanction of the Administration. The ships crew are currently conducting modifications to the Alternate Management System for the Ballast Water Management System, and stated they did not plan on having Flag State or class society attest and approve the modifications.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 January 2018
Resolution: Received, reviewed and accepted class report confirming deficiency has been rectified.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Pump Power Supply
Issued 18 January 2017
Resolved
01 0720 Fire protection systems and fire fighting systems and appliances shall be maintained ready for use. The tyco seaplus water mist system was found by the PSCO to be in the "manual" position. 74SOLAS II-2 14.1.1 10c
Action required: 705 - Other - as specified
Resolved 18 January 2017
Resolution: System was switched to "automatic" mode.