MAURY USCG vessel records
← All vessels

POLA MUROM

POLA MUROM is a 2014 freight ship. The Coast Guard has recorded 3 inspections since 2016, most recently in May 2024, along with 1 deficiency — 1 with no resolution recorded —.

Records from 2016 to 2024. Most recent: inspection, 11 May 2024.

Built
2014
Last inspected
11 May 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 11 May 2024
Operational controls None recorded without a removal date
Years with a record 3 calendar years (2016–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9674385
9HA3447
1320400
Flag
MALTA
Maury page id
psix-1320400

Documentation record

Tonnage as PSIX records it24199 - Convention (Subpart B), Gross Ton
37634 - Dead Weight, Metric Ton
47837 - Displacement, Metric Ton
12794 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

11 May 2024 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7910397
19 January 2017 Ballast Water Examination · ISPS II Exam · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6070477
6 November 2016 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6031570

Deficiency record · 1

Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 19 January 2017 No resolution recorded
9900-Other ( not clearly hazardous) Each loading arm and each transfer pipe system, including each metallic hose, must not leak under static liquid pressure at least 1.5 times the maximum allowable working pressure. PSCO observed test records for the last two years being conducted with the test pressure at 100% MAWP.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.