MAURY USCG vessel records
← All vessels

AGIOS NIKOLAS

AGIOS NIKOLAS is a 2014 freight ship. The Coast Guard has recorded 7 inspections since 2016, most recently in March 2024, along with 1 deficiency and 1 operational control.

Records from 2016 to 2024. Most recent: inspection, 31 March 2024.

Built
2014
Last inspected
31 March 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9702728
1320421
Flag
MARSHALL ISLANDS
Maury page id
psix-1320421

Inspections, by type

…with no type recorded2
Years with a record 5 calendar years (2016–2024)
The 7 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it32360 - Convention (Subpart B), Gross Ton
57902 - Dead Weight, Metric Ton
67810 - Displacement, Metric Ton
19448 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 7

31 March 2024 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7882597
24 March 2024 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7884064
31 May 2023 PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7693163
26 September 2019 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6816093
25 September 2019 Type not recorded
No type recorded · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 6816656
25 April 2018 ISPS II Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6396587
28 November 2016 Ballast Water Examination · Administrative Inspection · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6042446

Deficiency record · 1

07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 26 September 2019 Resolved
A FIXED FIRE DETECTION SYSTEM SHALL BE PROVIDED IN ACCORDANCE WITH THE PREVISIONS OF THIS REGULATION. THE VESSEL'S MASTER NOTIFIED PSCO'S OF INOPERABLE FIXED FIRE DETECTION SYSTEM. CLASS TO ATTEST TO PROPER FUNCTION OF FIXED FIRE DETECTION SYSTEM. 74 SOLAS (14) II-2/7.2.1
Action required: 17 - Rectify deficiencies prior to departure
Due 26 September 2019
Resolved 1 October 2019
Resolution: Received, reviewed and accepted class report from NKK stating the deficiency was rectified. The Class surveyor reviewed technician's report and conducted successful fire detection system test.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.