← All vessels
BW MISTRAL
BW MISTRAL is a 2015 tank ship. The Coast Guard has recorded 22 inspections since 2016, most recently in March 2026, along with 6 deficiencies and 2 operational controls.
Records from 2016 to 2026. Most recent: inspection, 17 March 2026.
- Built
- 2015
- Last inspected
- 17 March 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9667540 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7FA5
1320517
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1320517
Inspections, by type
…with no type recorded3
Years with a record
11 calendar years (2016–2026)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it46789 - Regulatory (Subpart C or D), Gross Ton
18825 - Regulatory (Subpart C or D), Net Ton
73415 - Displacement, Metric Ton
53854 - Dead Weight, Metric Ton
46789 - Convention (Subpart B), Gross Ton
18825 - Convention (Subpart B), Net Ton
18825 - Regulatory (Subpart C or D), Net Ton
73415 - Displacement, Metric Ton
53854 - Dead Weight, Metric Ton
46789 - Convention (Subpart B), Gross Ton
18825 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
17 March 2026
COC-GAS Annual · Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8327476
5 October 2025
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8246537
18 February 2025
PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8079610
11 April 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7893709
9 March 2024
PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7871766
3 January 2023
Administrative Inspection · COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7613746
16 June 2022
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7503334
25 July 2021
PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7257363
19 July 2021
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7283946
1 September 2020
PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7047317
23 August 2020
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7041457
13 May 2020
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6952520
17 June 2019
COC-GAS Renew · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6705457
16 October 2018
Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6557024
12 October 2018
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6560315
18 April 2018
ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6388243
11 December 2017
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6322057
3 May 2017
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6138328
14 April 2017
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6124026
19 May 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5881098
11 March 2016
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 5876257
9 March 2016
ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5830173
Deficiency record · 6
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2024
Resolved
ELECTRICAL INSTALLATIONS SHOULD BE SUCH AS TO MINIMIZE THE RISK OF FIRE AND EXPLOSION FROM FLAMMABLE PRODUCTS.
PSCO IDENTIFIED MULTIPLE LIGHTS WITHIN HAZARDOUS ZONES HAVING ELECTRICAL PUTTY AROUND PACKING GLANDS AND BROKEN BONDING STRAPS, RENDERING THEM TO NOT BE CERTIFIED SAFE.
IGC CODE 1993 10.1.2
40AC
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 17 June 2019
Resolved
Each flammable gas detection system must have an audible and visual alarm for loss of gas sampling flow. Flow meter guage for fixed gas detection in the cabinet was found in the open position, even when flow was secured to the cabinet. 17c. 46CFR154.1350(f).
Engineering › Pressure Vessel › Relief Valve
Issued 18 April 2018
Resolved
Pressure relief valves should be set and sealed by a competent authority acceptable to the Administration and a record of this action, including the values of set pressure, should be retained aboard the ship. The Lloyd's Register Certificate of Values, dated 19AUGUST2013, state the test pressure was 3.3 bar but the valve set pressure is 0.25 and 0.45 bar. Verify that the presure relief valves meet the requirement listed in IGC Code (1993 edition) 8.2.5. SOLAS 74 (2014 edition) Ch. VII/13.1, IGC Code (1993 edition) Ch. 8.2.5
Deck/Cargo › Cargo Stowage › General
Issued 11 December 2017
Resolved
Cargo tank PRV vent exits should be arranged at distance at least equal to B or 25m, which ever is less from nearest air intake or opening to accomd. spaces, or other gas safe spaces.
Vent mast for cargo tank #4 does not meet 25m distance requirement. 74SOLAS(14)VII/13.1, IGC(93)8.2.10
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 14 April 2017
Resolved
1099-ALARMS SIGNALS-An audible and visual alarm system to give warning on both sides of the airlock should be provided to indicate if more than one door is moved from the closed position. The alarms are installed outside on the weather deck and inside the airlock vice inside the electric motor room.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 19 May 2016
Resolved
Vessel experienced fire that damaged the scavenger box on the main engine. Vessel is returning to port to effect repairs.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.