BW MISTRAL

BW MISTRAL is a 2015 tank ship. The Coast Guard has recorded 22 inspections since 2016, most recently in March 2026, along with 6 deficiencies and 2 operational controls.

Records from 2016 to 2026. Most recent: inspection, 17 March 2026.

Built
2015
Last inspected
17 March 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 March 2026
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9667540
1320517
Flag
MARSHALL ISLANDS
Maury page id
psix-1320517

Documentation record

Tonnage as PSIX records it46789 - Regulatory (Subpart C or D), Gross Ton
18825 - Regulatory (Subpart C or D), Net Ton
73415 - Displacement, Metric Ton
53854 - Dead Weight, Metric Ton
46789 - Convention (Subpart B), Gross Ton
18825 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

17 March 2026 COC-GAS Annual · Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8327476
5 October 2025 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8246537
18 February 2025 PSC B · COC-GAS Renew
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8079610
11 April 2024 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7893709
9 March 2024 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7871766
3 January 2023 Administrative Inspection · COC-GAS Renew · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7613746
16 June 2022 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7503334
25 July 2021 PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7257363
19 July 2021 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7283946
1 September 2020 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7047317
23 August 2020 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7041457
13 May 2020 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6952520
17 June 2019 COC-GAS Renew · ISPS II Exam · Ballast Water Examination · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6705457
16 October 2018 Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6557024
12 October 2018 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6560315
18 April 2018 ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6388243
11 December 2017 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6322057
3 May 2017 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6138328
14 April 2017 Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6124026
19 May 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5881098
11 March 2016 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 5876257
9 March 2016 ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5830173

Deficiency record · 6

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 March 2024 Resolved
ELECTRICAL INSTALLATIONS SHOULD BE SUCH AS TO MINIMIZE THE RISK OF FIRE AND EXPLOSION FROM FLAMMABLE PRODUCTS. PSCO IDENTIFIED MULTIPLE LIGHTS WITHIN HAZARDOUS ZONES HAVING ELECTRICAL PUTTY AROUND PACKING GLANDS AND BROKEN BONDING STRAPS, RENDERING THEM TO NOT BE CERTIFIED SAFE. IGC CODE 1993 10.1.2 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 May 2024
Resolved 11 April 2024
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 17 June 2019 Resolved
Each flammable gas detection system must have an audible and visual alarm for loss of gas sampling flow. Flow meter guage for fixed gas detection in the cabinet was found in the open position, even when flow was secured to the cabinet. 17c. 46CFR154.1350(f).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2019
Resolution: SERVICE REPOPT RECIEVED- SEE ATTACHED
Engineering › Pressure Vessel › Relief Valve
Issued 18 April 2018 Resolved
Pressure relief valves should be set and sealed by a competent authority acceptable to the Administration and a record of this action, including the values of set pressure, should be retained aboard the ship. The Lloyd's Register Certificate of Values, dated 19AUGUST2013, state the test pressure was 3.3 bar but the valve set pressure is 0.25 and 0.45 bar. Verify that the presure relief valves meet the requirement listed in IGC Code (1993 edition) 8.2.5. SOLAS 74 (2014 edition) Ch. VII/13.1, IGC Code (1993 edition) Ch. 8.2.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 October 2018
Resolution: Vessel master provided the correct Safety Relief Test Report for all valves. Test Pressure listed on Lloyds Certificate for valves indicates Hydraulic Test for the entire system. Test Pressure for valves is indicated separately.
Deck/Cargo › Cargo Stowage › General
Issued 11 December 2017 Resolved
Cargo tank PRV vent exits should be arranged at distance at least equal to B or 25m, which ever is less from nearest air intake or opening to accomd. spaces, or other gas safe spaces. Vent mast for cargo tank #4 does not meet 25m distance requirement. 74SOLAS(14)VII/13.1, IGC(93)8.2.10
Condition: Design Flaw
Due 11 June 2018
Resolved 16 October 2018
Resolution: SOE reissued with special restriction per MSC.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 14 April 2017 Resolved
1099-ALARMS SIGNALS-An audible and visual alarm system to give warning on both sides of the airlock should be provided to indicate if more than one door is moved from the closed position. The alarms are installed outside on the weather deck and inside the airlock vice inside the electric motor room.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 May 2017
Resolution: Vessel submitted Class approved plans and photos of corrective actions relocating the airlock alarm to inside the motor room
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 19 May 2016 Resolved
Vessel experienced fire that damaged the scavenger box on the main engine. Vessel is returning to port to effect repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2016
Resolution: Received class report atesting to the working condition of the No.5 cylinder.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.