MAURY USCG vessel records
← All vessels

COOL RUNNER

COOL RUNNER is a 2014 tank ship. The Coast Guard has recorded 13 inspections since 2018, most recently in August 2025, along with 4 deficiencies and 1 operational control.

Records from 2018 to 2025. Most recent: inspection, 18 August 2025.

Built
2014
Last inspected
18 August 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 August 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2018–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9636797
9HA3506
1320944
Flag
MALTA
Maury page id
psix-1320944

Documentation record

Tonnage as PSIX records it102097 - Convention (Subpart B), Gross Ton
30630 - Convention (Subpart B), Net Ton
81890 - Dead Weight, Metric Ton
112216 - Displacement, Metric Ton
102097 - Regulatory (Subpart C or D), Gross Ton
102097 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

18 August 2025 PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8207634
22 May 2024 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 7913042
7 June 2023 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7706373
5 May 2023 PSC B · COC-GAS Annual
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7681549
25 April 2022 COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7433773
25 April 2022 Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 7443232
13 December 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7367541
21 April 2021 COC-GAS Annual · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7175026
6 March 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7151294
15 March 2020 PSC C · COC-GAS Renew
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6921043
3 May 2019 ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6669293
5 April 2018 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6386074
26 February 2018 COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6358801

Deficiency record · 4

09 - Working and Living Conditions › 092 - Working Conditions › Gas instruments
Issued 5 May 2023 Resolved
09213-Gas detection Systems provided in accordance with the requirements of 13.6.4. PSCO observed the fix gas detection repeater on the navigation bridge was in fault condition and would not provide an audible and visual alarm on the bridge. 74 SOLAS (20) VII/13.1 IGC(93) 16.3.10 60ac
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 5 May 2023
Resolved 5 May 2023
Resolution: Received Class report (DNV) stating that the alarms are covered by the secondary redundant control & monitoring on the bridge.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 May 2023 Resolved
02199-The condition of the ship and its equipment should be maintained to conform w/the provisions of the code. PSCO observed the vessel's water curtain had leaks repaired with epoxy. 74SOLAS(20) VII/13.1 IGC (93) 16.3.10 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 June 2023
Resolved 7 June 2023
Resolution: Documentation has been provided from Class attesting that the deficiency has been rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 5 May 2023 Resolved
09201-In rooms housing electric motors driving cargo compressors if considered gas safe the ventilation should be positive type. PSCO observed the machinery space ventilation had negative ventilation. Ship's crew switched to #1 vent supply and ventilation turned positive. 74SOLAS(20) VII/13.1 IGC (93) 12.1.4 10c
Action required: 10 - Deficiency Rectified
Due 5 May 2023
Resolved 5 May 2023
Resolution: The vessel's crew switched to #1 vent supply turning the ventilation positive.
Deck/Cargo › Cargo Stowage › General
Issued 26 February 2018 Resolved
A Master [name withheld] that can be closed within the machinery space should be provided within the cargo ara. The valve should be arranged so as to close automatically if the leakage of teh gas is detected, or loss of ventilation for the duct or casing or loss of pressurization of the double wall gas fuel piping occurs. The automatic valves that close the event of gas leakage, loss of venilation for the duct or casing, or loss of presuization of the double wall gas fuel piping are located of the after part of teh vessel, before it enters the machinery space, and not in the cargo area. IGC gas code 16.3.7
Condition: Design Flaw
Action required: 15 - Rectify deficiencies by next port
Due 1 July 2018
Resolved 5 April 2018
Resolution: Received acceptance from administraion allowing an equivalent means of safety reflected on the International Certificate of Fitness for the Carriage of Liquefied Gases in Bulk.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.