MAURY USCG vessel records
← All vessels

AFRICAN CONDOR

AFRICAN CONDOR is a 2014 freight ship. The Coast Guard has recorded 5 inspections since 2017, most recently in May 2024, along with 1 deficiency and 2 operational controls.

Records from 2017 to 2024. Most recent: inspection, 25 May 2024.

Built
2014
Last inspected
25 May 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9646900
1321066
Flag
BAHAMAS, THE
Maury page id
psix-1321066

Inspections, by type

Years with a record 3 calendar years (2017–2024)
The 5 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it24725 - Convention (Subpart B), Gross Ton
40481 - Dead Weight, Metric Ton
50248 - Displacement, Metric Ton
13677 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 5

25 May 2024 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7914260
17 May 2024 Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7914325
2 May 2018 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6403904
27 March 2018 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6381372
15 February 2017 PII Safety Exam · Ballast Water Examination · COE-Offshore · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6086487

Deficiency record · 1

Lifesaving › Lifeboat Equipment › Water/Water Receptacles
Issued 9 April 2018 Resolved
74 SOLAS (14) III/34, LSA Code IV/4.4.8.9 Equip of lifeboat shall consist of a watertight receptacle containing a total of 3L of freshwater for each person the lifeboat is permitted to accommodate. Vsl's lifeboat is capable of carrying 25 persons (which requires 75L) and stocked only with 64L (enough for current crew compliment)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2018
Resolved 2 May 2018
Resolution: Master provided purchase order to attest that additional water was procured for the lifeboat.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.