MAURY USCG vessel records
← All vessels

NAVIOS AVIOR

NAVIOS AVIOR is a 2012 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in November 2025, along with 2 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 20 November 2025.

Built
2012
Last inspected
20 November 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 November 2025
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9590084
1321116
Flag
PANAMA
Maury page id
psix-1321116

Documentation record

Tonnage as PSIX records it94985 - Displacement, Metric Ton
81354 - Dead Weight, Metric Ton
44282 - Convention (Subpart B), Gross Ton
27133 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

20 November 2025 PSC B
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8271414
13 June 2024 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7929355
20 December 2023 Administrative Inspection · PSC B · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7837646
11 December 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7837767
22 October 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7581958
3 September 2021 PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7292320
20 August 2021 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7292318
21 July 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5947872
20 May 2016 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5881936

Deficiency record · 2

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 December 2023 Resolved
The machinery and associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to person on board. PSCO observed the vessel's cascade tank walls heavily oiled and with significant oil accumulated on the water's surface. 74SOLAS(20)II-1/26.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 June 2024
Resolution: Received class report from [name withheld] attesting to repair of heating coil and verified water inside cascade tank was clear and free of oil accumulation.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 3 September 2021 Resolved
Stairways and lift trunks which penetrate more than a single deck shall be surrounded by at least "A-0" class divisions and be protected by self-closing doors at all levels. Upper deck self-closing door was found by PSCO to be modified and unable to properly seal to create a fire boundary. Door is for stairway entry. Door has been modified to add structural reinforced for handle. 14 SOLAS (Cons.) II-2/2.3.4.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 October 2021
Resolved 22 October 2022
Resolution: RCVD CLASS REPORT ISSUED BY LLOYD'S REGISTER STATING THAT THE A60 DOOR WAS REPLACED

Ownership record