J L O'BRIEN

J L O'BRIEN is a 2016 oil recovery. The Coast Guard has recorded 13 inspections since 2017, most recently in October 2025, along with 10 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 6 October 2025.

Built
2016
Last inspected
6 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDJ2749
1321165
Flag
UNITED STATES
Maury page id
psix-1321165

Inspections, by type

Years with a record 9 calendar years (2017–2025)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)79.5 ft × 21.0 ft × 5.3 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)79.5 ft × 21.0 ft × 5.3 ft
ITC tonnagegross 123 / net 36
BuilderMIDSHIP MARINE INC · HARVEY, LA, UNITED STATES · built 2016
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLEEVILLE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 August 2025 · expires 31 August 2026
Service, as the file records itOil Recovery
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it123 - Convention (Subpart B), Gross Ton
95 - Regulatory (Subpart C or D), Gross Ton
36 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

6 October 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8246884
16 October 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8012073
7 October 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8015369
4 October 2023 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7803674
24 October 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7581244
5 October 2022 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7566401
17 November 2021 Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7352090
7 December 2020 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7107399
14 November 2019 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6855091
5 November 2019 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6841007
17 December 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6599104
5 December 2017 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6318861
15 November 2017 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6307680

Deficiency record · 10

03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 October 2022 Resolved
Each watertight bulkhead must be of sufficient strength to be cababile of remaining fire resistant & watertight. Fire/Water Stop in watertight bulkhead had a hole drilled w/o being replaced from the accomidations space to the enigine room through the watertight hallway.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 October 2022
Resolution: Crew replaced fire/water stop to the satisfaction of the MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 5 October 2022 Resolved
Each watertight door must be of suficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. The gasket material in the two WTDs for the hallway were soft & not able to remain watertight.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2022
Resolution: Crew replaced gaskets to the satisfaction fo the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 November 2021 Resolved
Each ring life buoy must be marked with Type II retroreflective material; one (01) ring life buoy’s retroreflective material was torn, needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 November 2021
Resolution: Retroreflective tape replaced
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 November 2021 Resolved
Each ring life buoy must be approved in accordance with subchapter Q (46 CFR 160.050); grab line on starboard side ring life buoy was frayed and brittle, needs replacement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 November 2021
Resolution: New ring life buoy purchased.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 November 2021 Resolved
Inland navigation rules contained in 33 CFR 83 subpart C shall be complied with in all weathers; vessel only had two (02) ball day shapes, and would not be capable of complying with all day shape configurations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 November 2021
Resolution: New dayshape purchased.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 17 November 2021 Resolved
All watertight doors in subdivision bulkheads must be kept tightly closed during the navigation of the vessel except when being used for transit between compartments; four (04) dogs were found to not seal tightly on three (03) watertight doors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 November 2021
Resolution: Dogs on watertight doors tightened.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 November 2021 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck; two (02) emergency lights were not working.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 November 2021
Resolution: Batteries replaced
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 17 November 2021 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable 30x30 mesh flame screens or flame arresters; flame screen for fuel tank vent on aft starboard deck had been worn down and was no longer sufficient.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 November 2021
Resolution: Flame screen replaced
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 14 November 2019 Resolved
The emergency lighting must automatically actuate upon failure of the main lighting system. Emergency lighting in rudder room failed to turn on during testing of emergency power source.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 December 2019
Resolved 15 November 2019
Resolution: Vessel provided pictures of newly installed e-light battery, that activated upon failure to primary power source.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 December 2018 Resolved
Replace expired hydrostatic release unit on EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2018
Resolution: Vessel replaced hydrostatic release.