MAURY USCG vessel records Sign in
← All vessels

ISLAND PERFORMER

ISLAND PERFORMER is a 2014 offshore supply vessel. The Coast Guard has recorded 27 inspections since 2015, most recently in February 2026, along with 4 deficiencies and 2 operational controls.

Records from 2015 to 2026. Most recent: inspection, 24 February 2026.

Built
2014
Last inspected
24 February 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9682045 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1321630
Flag
VANUATU
—
Maury page id
psix-1321630

Inspections, by type

…with no type recorded8
Years with a record 11 calendar years (2015–2026)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it16488 - Displacement, Metric Ton
7088 - Dead Weight, Metric Ton
12983 - Convention (Subpart B), Gross Ton
3895 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

24 February 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8315145
28 January 2026 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8302834
23 December 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8286745
9 December 2025 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8395744
4 December 2025 Administrative Inspection · Deficiency Check · PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8277436
8 July 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8183131
27 June 2025 In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8168605
24 June 2025 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8166621
5 May 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8129193
14 April 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8111694
21 March 2025 PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8096110
28 June 2024 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7986457
6 February 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7719225
17 January 2023 PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7621447
3 January 2021 PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7118480
2 July 2020 PSC B
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6991280
22 January 2020 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7059124
11 December 2019 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6872992
6 September 2019 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6804416
2 May 2019 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6675955
29 April 2019 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6673765
29 August 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6519033
21 March 2017 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6110928
24 February 2017 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6095399
12 December 2016 ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6056200
26 July 2016 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5954566
15 December 2015 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5782352

Deficiency record · 4

14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 8 December 2025 Resolved
Each ballast water management system manufactred under Coast Guard approver must have a name plate which is securly fastened to the BWMS and plainly marked by the manufacturer. BWMS did not have a name plate with approval number seurly fastened to the system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 January 2026
Resolved 9 June 2026
Resolution: Installed name plate with approval number on the system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 December 2025 Resolved
Before the ship leaves port 4 at all times during a voyage, all life saving appliences shall be in good working order. PSCO's observed STBD side 4.0 KG Bouy was starting to crack and split.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 December 2025
Resolved 8 December 2025
Resolution: Replaced with spare in good condition.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 December 2025 Resolved
Each life buoy shall be marked in roman capital letters with name of the ship and port of registry. Multiple buoys were found to have faded letters.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2025
Resolved 23 December 2025
Resolution: Vessel provided pictures of corrected life buoys.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 29 August 2018 Resolved
07106 – Fire Detection and alarm system - Fire protection systems and firefighting systems and appliances shall be maintained ready for use. PSCO observed that a plastic bag was covering the flame detector in the incinerator space. Plastic bag was then removed, and PSCO witnessed a satisfactory test. SOLAS 74 (2014 cons.) II-2 / Reg. 14.1.1 10c
Action required: 10 - Deficiency Rectified
Due 29 August 2018
Resolved 29 August 2018
Resolution: PSCO observed that the plastic bag was removed from the flame detector, and the PSCO witnessed a satisfactory test of the flame detector.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.