Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it20069 - Convention (Subpart B), Gross Ton 10093 - Convention (Subpart B), Net Ton 30166 - Dead Weight, Ton 39053 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
Inspection history · 4
5 March 2025PSC B
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 8086706
28 June 2018Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6458441
7 June 2017Deficiency Check · ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6163215
6 May 2016Ballast Water Examination · ISPS II Exam · PII Safety Exam
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 7 June 2017Resolved
The ship shall be divided by thermal and structural boundaries to contian a fire to its space of origin. The PSCO observed ne ducting that passed through class A bulkheads in the several accomodation spaces to include laundry and passageway. The space between the duct and the penetration fitting was sealed with duct tape and not a suitable non-combustible material. 74 SOLAS (04 Cons) II-2/9.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2017
Resolution: Class report attesting that incombustible sealing compound was placedin the space around the ducting inside the bulkhead fittings.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 7 June 2017Resolved
After any survey of a ship has been completed, no change shall be made to structural components covered by the survey without the santion of the administration. The PSCO observed new ventilation duct penetrating class A bulkheads within accomodation spaces, and the penetrations were sealed with duct tape and not a suitable non-combustible material.
74 SOLAS (04 Cons.) II-2/9.1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 June 2017
Resolution: Class report attesting that incombustible sealing compound was placedin the space around the ducting inside the bulkhead fittings.
After any survey of the ship is completed, no change shall be made in the equipment covered by the survey without the sanction of the administration. The PSCO observed 4 mooring hawsers with nylon strap spliced/woven into the strands at verious points to reduce chaffing. 74 SOLAS (14 Cons) I/11.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 June 2017
Resolution: Class issued recommendation on Form ATT to address the mooring line conditions
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 7 June 2017Resolved
In meeting these requirements the company should ensure that inspections are conducted at appropriate intervals and appropriate corrective action is taken. The ships crew has not conducted inspections on hawsers every 3 months as required by SMS and accurate record of wear was not kept. 74 SOLAS (14 Cons) IX/5 ISM Code 10.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 June 2017
Resolution: Class issued recommendation on Form ATT to address the mooring line conditions and Form ISM-NTF regarding possible ISM failure.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.