MAURY USCG vessel records
← All vessels

KIRBY-SMITH

KIRBY-SMITH is a 2014 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in January 2026, along with 26 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 28 January 2026.

Built
2014
Last inspected
28 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 January 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH7641
1322260
Flag
UNITED STATES
Maury page id
psix-1322260

Documentation record

Tonnage as PSIX records it4 - Simplified, Gross Ton
4 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

28 January 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8301892
10 April 2025 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8108970
11 February 2025 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 8077772
7 March 2024 Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7875371
26 April 2023 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7676758
13 December 2022 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7608540
12 July 2022 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7504969
13 October 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7331594
3 May 2021 Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7187988
21 July 2020 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7021682
9 April 2020 Administrative Inspection
Administrative · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6937890
25 April 2019 Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6663805
7 May 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6403464
8 May 2017 Annual Inspection · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 6152252
11 March 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5831354

Deficiency record · 26

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 28 January 2026 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2026
Resolved 29 January 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 December 2022 Resolved
The regulations in this part provide a means to minimize the use of intoxicants by merchant marine personnel and to promote a drug free and safe work environment. Provide drug and alcohol program with employee list on-board the vessel. Display EAP community service hot-line telephone number for crew-members.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 December 2022
Resolved 28 December 2022
Resolution: Master posted EAP hotline in crew room and provided drug and alcohol program onboard the vessel.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 December 2022 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. The training entry shall include the following information. (1) Date of the training; and (2) General description of the training topics. Properly log required crew training.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 December 2022
Resolved 28 December 2022
Resolution: Master logged emergency drills in logbook.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 December 2022 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Provide proper container onboard the vessel separate from general items.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 26 December 2022
Resolved 28 December 2022
Resolution: Portable watertight container provided onboard and properly labeled.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 December 2022 Resolved
A vessel of less than 12 meters in length shall be provided with means of making an efficient sound signal. Provide sound signal on the vessel and prove operation.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 December 2022
Resolved 28 December 2022
Resolution: Master provided means of efficient sound signal onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 December 2022 Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Properly separate child life jackets from adult sized life jackets.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2023
Resolved 28 December 2022
Resolution: Adult lifejackets properley stowed separated from child lifejackets.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 December 2022 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Provide a proper first aid kit onboard the vessel.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 January 2023
Resolved 28 December 2022
Resolution: New first aid kit installed onboard the vessel.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 December 2022 Resolved
Vessel must be equipped with dsc VHF radio. Properly integrate VHF radio with GPS and conduct proper radio check.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2023
Resolved 28 December 2022
Resolution: New VHF with integrated GPS installed and properly tested.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 13 December 2022 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. The vessel is overdue for its required annual inspection.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 December 2022
Resolution: COI inspection conducted on this date, issued CG835V to Master.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 October 2021 Resolved
Each life jacket kept in a stowage container must be readily available. During MI spot check, multiple handles were not working as design.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2021
Resolved 8 November 2021
Resolution: The doors on the life jacket stowage were removed for ease of getting to them. The stowage compartment was properly labeled IAW 46 CFR 180.78
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2021 Resolved
Each small battery install must be protected from falling objects. MI discovered batteries had no protective cover installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2021
Resolved 25 October 2021
Resolution: The terminals are properly covered protecting from falling objects.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 13 October 2021 Resolved
Distress flare container shall be clearly marked "DISTRESS SIGNALS" in .05" letters. Container was not properly labled.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2021
Resolved 19 October 2021
Resolution: Containers were properly labeled with .5" letters "DISTRESS SIGNALS"
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 13 October 2021 Resolved
FCC safety radio telephone certificate must be valid and onboard. Exisiting certificate was expired. Cite: 47CFR80.13 705: not to exceed 1000' from shore or 30 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 November 2021
Resolved 18 October 2021
Resolution: Provided documentation satisfying the requirement to the attending inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 May 2021 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and internal structural examination at least once every two years. The vessel is overdue for its required drydock and internal structural examination and must be completed prior to the carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2021
Resolution: Hull exam and ISE was conducted this date.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 April 2020 Resolved
As of 1/29/2020, COI has expired. No passengers are allowed to be carried on-board until a satisfactory inspection and until you have recieved a new signed COI and SPV sticker.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 July 2020
Resolution: COMPLETED COI INSPECTION
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 April 2019 Resolved
Provide approved first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2019
Resolved 2 May 2019
Resolution: Provided photo of new first aid kit onboard.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 April 2019 Resolved
Provide proof of servicing on fire extinguisher.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2019
Resolved 2 May 2019
Resolution: Provided photo if fire ext. servicing aboard vsl.
Lifesaving › Lifejacket/PFD (Type III) › Storage
Issued 7 May 2018 Resolved
STBD life jacket hatch broken latch and will not open
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 10 June 2018
Resolution: Provided proof of proper markings, accepted and cleared.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 May 2018 Resolved
Retro tape missing on FWD lifering top due to name being in the way, add strips above and below. Aft life ring missing retro.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 10 June 2018
Resolution: Provided proof of proper marking, accepted and cleared.
Documentation › Certificates/Documents › Permit, Other
Issued 7 May 2018 Resolved
FCC operators permit not issued to [name withheld] operators permit.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 June 2018
Resolved 10 June 2018
Resolution: Provided proof for proper documentation, accepted and cleared.
Engineering › Fuel Oil Service System › Valve, Control
Issued 11 March 2016 Resolved
post fuel valve shut off position.
Condition: Improper/Lack of Maintenance
Due 14 April 2016
Resolved 19 April 2016
Fire Fighting › Fire Bucket › Stenciling
Issued 11 March 2016 Resolved
re-lable fire buckets.
Condition: Improper/Lack of Maintenance
Due 14 April 2016
Resolved 19 April 2016
Construction/Loadline › Structures › Superstructure
Issued 11 March 2016 Resolved
repair cracked welds on T-top.
Condition: Improper/Lack of Maintenance
Due 14 April 2016
Resolved 19 April 2016
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 11 March 2016 Resolved
provide service of fire extinguishers.
Condition: Improper/Lack of Maintenance
Due 14 April 2016
Resolved 19 April 2016
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 March 2016 Resolved
provide proof of enrolement in maritime consortium.
Condition: Improper/Lack of Maintenance
Due 14 April 2016
Resolved 19 April 2016
Engineering › Bilge Water Management System › Pump
Issued 11 March 2016 Resolved
provide bilge pump that mets UL 1113 requirements.
Condition: Improper/Lack of Maintenance
Due 14 April 2016
Resolved 19 April 2016

Ownership record