Records from 2016 to 2026. Most recent: inspection, 23 April 2026.
Inspection history · 19
23 April 2026
COI Inspection · Special Consideration · Drydock Exam · Administrative Inspection · DAPI Audit · Internal Structural Exam · Vessel Attendance
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8354700
28 October 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8026309
6 August 2024
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7922367
8 June 2023
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7709634
25 October 2022
Internal Structural Exam · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7582728
4 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7573499
23 May 2022
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7455127
24 May 2021
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7194943
23 November 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7114786
25 June 2020
COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6983860
9 March 2020
In-Service Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6923143
25 June 2019
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6723762
29 November 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6589131
24 September 2018
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6545482
9 November 2017
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6304345
19 June 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6169231
21 March 2017
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6108797
1 November 2016
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6023677
8 September 2016
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5975021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 August 2024
Resolved
46 CFR 182.610 (a)
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. MI observed that steering system was leaking near reservoir in upper aft engine room. Vessel shall enact permanent repairs to the satisfaction of attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2024
Resolved 28 October 2024
Resolution: Steering leak repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 August 2024
Resolved
46 CFR 182.530 (a)
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A machinery space bilge, a space with a through-hull fitting below the deepest load waterline. MI observed that bilge alarms in engine room, and space forward of engine room were not operational. Vessel shall enact permanent repairs to the satisfaction of attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2024
Resolved 28 October 2024
Resolution: Bilge alarms are operational.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 August 2024
Resolved
46 CFR 185.740 (b)
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. MI observed that the hydrostatic release wasn't marked with expiration date. Vessel shall replace hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 August 2024
Resolved 28 October 2024
Resolution: New EPIRB hydro statice release with expiration date.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2024
Resolved
46 CFR 180.70 (d)
A vessel must carry one floating waterlight, unless it is limited to daytime operation. MI observed that vessel didn't have a floating waterlight. Vessel shall install an approved floating waterlight.
CODE 705: Vessel is restricted to daytime operations.
Action required: 705 - Other - as specified
Due 6 August 2024
Resolved 11 November 2024
Resolution: Floating light was installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 August 2024
Resolved
46 CFR 183.420
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. MI observed that port navigation light was not operational. Vessel shall enact permanent repairs to the satisfaction of USCG marine inspector.
CODE 705: Vessel is restricted to daytime operations with 10 nautical miles of visibility.
Action required: 705 - Other - as specified
Due 6 August 2024
Resolved 28 October 2024
Resolution: Port navigation light is operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 August 2024
Resolved
46 CFR 180.70 (c)
At least one ring life buoy must be fitted with a lifeline. MI observed that lifeline was in need of replacement. Vessel shall replace lifeline.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 28 October 2024
Resolution: Lifeline replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 August 2024
Resolved
46 CFR 180.68 (a)
A vessel on a limited coastwise route must carry six
hand red flare distress signals, and six hand orange
smoke distress signals. MI observed vessel was missing
one red flare distress signal. Vessel have a total of
twelve distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 28 October 2024
Resolution: Distress signals replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 6 August 2024
Resolved
46 CFR 183.430
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel didn't have portable lights. Vessel shall install portable lights.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 28 October 2024
Resolution: Observed two operational portable lights.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 August 2024
Resolved
46 CFR 183.220 (a)
Electrical equipment and installations must be suitable for the roll, pitch, and vibration of the vessel underway. MI observed that engine room ventilation blower mount was starting to fail. Enact repairs to the satisfaction of attending USCG marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 28 October 2024
Resolution: Blower was removed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 August 2024
Resolved
46 CFR 184.710
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. MI observed that aspirin was expired. Replace aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 28 October 2024
Resolution: First aid kit replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2024
Resolved
46 CFR 185.516 (a)
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel has two types of life jackets but only a placard for one of the two types. Post placard for other life jacket type.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 28 October 2024
Resolution: Placard installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Doc evidence for personnel on passenger ships
Issued 6 August 2024
Resolved
46 CFR 16.500
(1) By March 15 of the year following the collection of the data in paragraph (a) of this section, marine employers must submit the data on the form titled U.S. Department of Transportation Drug and Alcohol Testing MIS Data Collection Form. A consortium or other employer representative may submit data for a marine employer. Reports may contain data for more than one marine employer. Each report, however, must list the marine employers included in the report. MIS report was not available.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 11 November 2024
Resolution: Received report.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 August 2024
Resolved
46 CFR 176.306
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. If posting is impracticable, the stability letter must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Stability letter was not provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 12 August 2024
Resolution: Sent vessel rep stability letter to be put in documents binder onboard vessel.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 6 August 2024
Resolved
46 CFR 184.420
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication, Coast Guard Light List, and navigation rules. Extracts from the publications listed above for the areas to be transited may be provided instead of the complete publication. Missing light list, coast pilot and navigation rules rules.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 28 October 2024
Resolution: Light list, coast pilot and navigation rules rules are onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 August 2024
Resolved
46 CFR 180.70
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Number of adult life jackets was inproperly labeled. Relabel adult life jacket stowage with 14.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 28 October 2024
Resolution: Stowage properly labeled.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 6 August 2024
Resolved
46 CFR 184.502
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications
Commission, as set forth in 47 CFR part 80. Missing FCC
Radio Safety Certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 11 November 2024
Resolution: Received station license.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 8 June 2023
Resolved
Life ring light inoperable, replace in kind.
46 CFR 180.70
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2024
Resolution: Float light being inoperable should have just resriceted vesel opeartions to daytime. Light was missing during annual on 06AUG24 (activity# 7922367). Seperate deficiency issued.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 June 2023
Resolved
Float switch for bilge high level in engine room is inoperable, replace in kind.
46 CFR 182.530
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 October 2024
Resolution: Bilge alarms are operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2023
Resolved
Several life jackets were corroded beyond serviceable condition, replace in kind.
46 CFR 180.71
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2024
Resolution: All life jackets were replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 June 2023
Resolved
Drug and Alcohol program is out of date as there are ongoing employee changes. All crew members must be enrolled in program prior to operation.
46 CFR 16.230
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 August 2024
Resolution: Vessel has been sold. new company has operators enrolled in a consortium.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 October 2022
Resolved
Vessel was identified as having potential damage from Hurricane IAN. Prior to conducting repairs, contact the local USCG Marine Inspections office and submit a repair proposal for approval. Vessel is not permitted to return to commercial service until cleared by a USCG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 October 2022
Resolution: Cleared based on objective evidence that vsl was not damaged by hurricane Ian.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 24 May 2021
Resolved
Safety Certificate out of date, must remain within 1,000 ft from shore until updated.
Action required: 705 - Other - as specified
Due 7 June 2021
Resolved 31 May 2021
Resolution: Received photo of new certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 May 2021
Resolved
Ring Buoy lines need to be corrected so light has correct line and hardwear.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 26 May 2021
Resolution: Received photo of correct configuration.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 May 2021
Resolved
Coast Pilot [name withheld] and tide tables need to be updated to current year.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2021
Resolved 26 May 2021
Resolution: Received photo of new publications onboard.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 25 June 2019
Resolved
Pre-engineered fire detection/suppression system is not connected to engine and will not operate according to regulation. Licensed technician required to attend and make operable.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2019
Resolution: Inspected installation, witnessed satisfactory demonstration of pre engineered fire detection/suppresion system for engine cutoff and overide.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 8 September 2016
Resolved
Hydrostatic release date cannot be verified, replace hydro.
Action required: 705 - Other - as specified
Due 22 September 2016
Resolved 29 September 2016
Resolution: purachsed new hydro.