← All vessels
PEPIN EXPRESS
PEPIN EXPRESS is a 1999 freight ship. The Coast Guard has recorded 54 inspections since 2015, most recently in August 2025, along with 49 deficiencies and 21 operational controls.
Records from 2015 to 2025. Most recent: inspection, 25 August 2025.
- Built
- 1999
- Last inspected
- 25 August 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 49 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9196228 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
51M723
1322590
Flag
TANZANIA
—
Maury page id
psix-1322590
Inspections, by type
…with no type recorded17
Years with a record
11 calendar years (2015–2025)
The 54 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it2035 - Convention (Subpart B), Gross Ton
1168 - Convention (Subpart B), Net Ton
2715 - Dead Weight, Metric Ton
3740 - Displacement, Metric Ton
1168 - Convention (Subpart B), Net Ton
2715 - Dead Weight, Metric Ton
3740 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 54
25 August 2025
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8217401
22 August 2025
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8219931
31 July 2025
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8199179
26 February 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8083495
27 January 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8069760
27 January 2025
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8070134
15 January 2025
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8062576
3 November 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8028680
25 October 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8023400
7 October 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8013657
27 September 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8007682
16 September 2024
ISPS Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8003736
10 June 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7931258
11 May 2024
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7910448
26 April 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7901225
8 April 2024
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7889934
5 March 2024
PSC A · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7872570
16 October 2023
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7806742
11 September 2023
Administrative Inspection · Deficiency Check · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7789265
9 February 2023
PSC A · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7633865
15 December 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7609517
8 August 2022
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7527757
8 June 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7471962
4 April 2022
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7424462
7 February 2022
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7391695
24 January 2022
PSC A · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7384466
6 December 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7362976
9 July 2021
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7250307
22 June 2021
Deficiency Check · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7231973
25 April 2021
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7182271
29 December 2020
PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7117155
19 June 2020
PSC A · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6981158
2 June 2020
PSC A · Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6965918
15 May 2020
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6953824
3 October 2019
Administrative Inspection · ISPS III Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6827324
4 April 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6655713
29 March 2019
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6684798
26 March 2019
PII Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6649491
30 October 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6568636
29 October 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6570487
25 September 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6548126
6 September 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6533905
22 August 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6519525
13 August 2018
Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6510192
12 February 2018
Administrative Inspection · PI Safety Exam · ISPS III Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6353866
23 September 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6273004
9 August 2017
Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6235114
8 August 2017
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6230547
27 January 2017
PI Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6078211
2 December 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6051434
17 June 2016
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5910634
5 April 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5847773
17 February 2016
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5817025
10 December 2015
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5778862
Deficiency record · 49
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company responsibility and authority
Issued 1 August 2025
Resolved
Every Company should develop, implement and maintain a safety management system (SMS) which includes instructions and procedures to ensure safe operation of ships and protection of the environment in compliance with relevant international and flag state legislation. The Dangerous Goods Document of Compliance prohibits the carriage of class 3 flammable cargoes. However, 12 dangerous cargo manifests (DCMs) confirm that the vessel transported more than 31,000 kilograms of class 3 flammable cargoes on nine voyages from April through July 2025. The master signed most of these DCMs. When questioned, the master stated that he received the DCMs after cargo was loaded and that he did not know he had the authority to reject the unauthorized cargo and order its removal before departure. The SMS does not require the crew to verify dangerous goods compliance before loading, nor does it address the master’s authority to reject unauthorized cargoes. Carriage of class 3 flammable cargoes without the required systems/equipment to fight a fire presents an unacceptable risk to the safety of the vessel, crew, and the marine environment. An external ISM audit is required.
74SOLAS(24) IX/3.1, ISM Code 1.4.2
Code 30bc
12 - Dangerous Goods › N/A - No Subsystem › Instrumentation
Issued 31 July 2025
Resolved
"The following ships with cargo spaces intended for the carriage of packaged dangerous goods shall comply with regulation 19.3... not later than the date of the first renewal survey on or after 1 January 2011: Cargo ships of 500 gross tonnage and upwards...constructed on or after 1 September 1984 but before 1 January 2011."
PSCO observed that the vessel was not authorized to carry class 3 dangerous goods by the administration due to the lack of required equipment necessary for the carriage of those goods listed in the previous dangerous cargo manifests reviewed.
74SOLAS(20) II-2/1.2.4.1
Code 17bc
01 - Certificates & Documentation › 013 - Documents › Cargo information
Issued 31 July 2025
Resolved
The carrier and its agents shall ensure that the master, or a licensed deck officer designated by the master and attached to the vessel... acknowledges the correctness of the dangerous cargo manifest, list or stowage plan by his signature. Multiple DCMs were not signed by the master or another licensed deck officer, including DCMs indicating the shipment of unauthorized class 3 flammable cargoes.
49CFR 176.30(c)
Code 17bc
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 27 January 2025
Resolved
Each vessel must have the following marine charts of the area to be transited that are corrected. PSCO observed cancelled charts as primary means of navigation.
33 CFR 164.33(a)(ii)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 27 January 2025
Resolved
Guard rails fitted on superstructure and freeboard decks shall have at least three courses. The opening below the lowest course shall not exceed 230mm. PSCO observed broken lower course.
ICL 66/88 Annex I/25.3
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 27 January 2025
Resolved
The sample is to be retained onboard not less than 12 months from the time of delivery. PSCO observed only 02 samples onboard and missing multiple samples in the 12 month span.
MARPOL(CONS. 22) ANNEX VI Reg 18.8.1
07 - Fire Safety › N/A - No Subsystem › Emergency Escape Breathing Device and disposition
Issued 8 April 2024
Resolved
A fireman's outfit shall consist of: Personal equipment comprising: Protective clothing of material to protect the skin from heat radiating from the fire and from burns. PSCO'S observed the fire fighting outfit had exposed skin around the fire fighting team members face.
74SOLAS(97) CH II-2 REG 17.1.1.1
14 - Pollution Prevention › 141 - MARPOL Annex I › Other (MARPOL Annex I)
Issued 8 April 2024
Resolved
No person may transfer oil or hazardous material to or from a vessel unless each parson in charge designated under 33 part 154.710 and 155.700 of this chapter has filled out and signed the declaration of inspection described in paragraph (c) of this section. PSCO'S observed vessel personnel transferring lube oil over the water with no declaration of inspection completed.
33CFR 156.150
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 5 March 2024
Resolved
Firefighting systems and appliances shall be kept in good working order and readily available for immediate use..
PSCO's were informed that the emergency fire pump is inoperable.
74 SOLAS (20) II-2 / 14.2.1.2
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 March 2024
Resolved
Ships shall comply with the relevant requirements of this chapter and of Part A of the ISPS Code, taking into account the guidance given in Part B of the ISPS Code...
Vessel was missing record of annual security exercise for 2023. A security exercise must be conducted prior to departure.
74 SOLAS (20) XI / 4.2
ISPS Code Part A / 10.1.1
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 5 March 2024
Resolved
The training manual shall be written in the working language of the ship.
PSCO's observed that the fire-fighting training manual was written in English but the working language of the ship is Spanish.
74 SOLAS (20) II-2 / 15.2.3.2
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 16 October 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. PSCO observed rescue boat engine did not start.
74SOLAS(97)III/19.2
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Resources and personnel
Issued 11 September 2023
Resolved
The company and the ship shall comply with the requirements ofthe International Safety Management Code. For the purpose of this regulation, the requirements of the Code shall be treated as mandatory.The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevantrules and regulations and with any additional requirements which may be established by the company. In meeting these requirements, the company should ensure that any non-conformityis reported, with its possible cause, if known.
The nature of the below deficiencies provides objective evidence of a serious failure of the implementation of the ISM Code. An external ISM audit report, satisfactory to the Coast Guard, mustbe submitted prior to clearance of this deficiency and departure.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 11 September 2023
Resolved
Each seafarer holding a certificate issued under the provisions of the Convention, who is serving at sea, shall also hold a medical certificate issued in accordance with the provisions of this regulation and of section A-1/9 of the STCW Code.
PSCO’s discovered that the medical certificate for the Chief
Engineer was expired.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 11 September 2023
Resolved
Except as provided in paragraphs (b) and (c) of this section no person may cause a vessel to enter into or get underway on the navigable waters of the United States unless no more than 12 hours before entering or getting underway, the following
equipment has been tested: Each rudder angle indicator in
relation to the actual position of the rudder.
The ship’s logbook showed that the pre-arrival checks were
completed. However, PSCO’s observed that the rudder angle
indicator repeater on the port side bridge wing conning station was inoperable, indicating an incomplete examination of the required equipment based on the fact that the crew was unaware of the last time that the indicator was functioning properly.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management Plan (BWMP)
Issued 9 February 2023
Resolved
VESSEL NEEDS APPROVED UPDATED PLAN TO REFLECT NEW BALLAST WATER TREATMENT SYSTEM.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 February 2022
Resolved
muster and embarkation station shall be adequately illuminated by lighting suplied from the emergency source of electrial power required by regulations II-1/42 or II-1/43 as appropriate. PSCO observed 02 lights not operational with emergency power located by the port side embarkation station. 74SOLAS(97) III/11.4
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 25 January 2022
Resolved
... a minimum of two inspections of the outside of the ship's bottom during any five year period. SOLAS Safety Construction Certificate provided to PSCOs listed the vessel's previous two drydocks as 17JAN2017 and March 2017. This is greater than 2 inspections in a 5 year period. Vessel plans to go to drydock in March 2022. 74 SOLAS(20 cons.) CH. I/ Reg. 10(a)(v). 17bc.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 25 January 2022
Resolved
The means for securing and maintaining weathertightness shall be to the satisfaction of the administration. PSCOs identified several cargo hatch securing devices which were rusted and wasted, warped, or missing all together. ICLL 66 Annex I/ Reg. 16.4. 17bc.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 January 2022
Resolved
Paint lockers and flammable liquid lockers shall be protected by an appropriate fire-extinguishing arrangement approved by the Administration. The current arrangement is not fixed and requires flooding of the entire space to fight a fire. 74 SOLAS (97 cons.) Ch. II/ Reg 18.7. 17bc
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 25 January 2022
Resolved
... The other courses shall not be more than 380 mm (15 inches) apart. The middle course of railing was missing near the rescue boat, port side. ICLL 66 Annex I/ Reg 25.3. 17bs.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 9 July 2021
Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use...The rescue boat sheave did not rotate as designed.
74 SOLAS (20) III/20.2
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Heating, air conditioning and ventilation
Issued 9 July 2021
Resolved
The secretary may order any vessel in a port or place of the United States or in the navigable waters of the United States, to operate or anchor in a manner the secretary directs...Condition of such vessel, the secretary is satisfied such direction is justified in the interest of safety...Vessel does not have a working AC system on board negatively impacting the health and safety of the crew.
46 USC 70002(3)
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Heating, air conditioning and ventilation
Issued 22 June 2021
Resolved
The Secretary may order any vessel in a port of place subject to the jurisdiction of the United States or in the navigable waters of the United States, to operate or anchor in a manner the Secretary directs if- by reason of... other hazardous circumstances, or the condition of such vessel, the Secretary is satisfied such discretion is justified in the interest of safety... vessel does not have a working A/C system on board, and all windows are permanently sealed, impeding air circulation, negatively impacting the health and safety of the crew.
46 USC 70002 (3)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 June 2021
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance is a fire occurs: Fire detection and alarm systems. Inspection observed a general fault on the bridge fire alarm panel that could not be cleared.
74 SOLAS (04 cons.) CH. II-2/Reg.2.1.1.2
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 June 2021
Resolved
After any survey of the ship under regulations 7, 8, 9 or 10 has been completed, no changes shall be made in the structural arrangements, machinery, equipment and other items covered by the survey, without sanction of the administration. On the starboard side of the vessel, inspectors observed a cargo hatch securing device that broke off.
74 SOLAS (04 cons.) CH. 1/Reg 11(b)
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 3 June 2020
Resolved
Oil filtering equipment referred to in paragraph 1 of this regulation shall be of a design approved by the administration.. OWS had numerous leaks on system, Pump Shaft seal leaks, Pump outlet pipe leaks and rupture on pump inlet pipe.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 2 June 2020
Resolved
Oil filtering equipment will ensure that any oily mixture discharged has an oil content not exceeding 15 PPM. Crew could not demonstrate proper operation of OWS.
MARPOL ANNEX I/REG 14.6
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 June 2020
Resolved
Except as provided in paragraph 4, two means of escape shall be provided from each machinery space of category A. Escape trunk serving as secondary means of escape from ENG room had hatch seized due to rust, preventing crewmember from opening the hatch from inside of the ship.
74SOLAS (97CONS) Ch. II-2/Reg 45.3
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 2 June 2020
Resolved
Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Crew initially able to steer to port only. After mechanical intervention, acceptable steering was demonstrated.
74SOLAS (97CONS) Ch. III/Reg 19.2
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 2 June 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 2 June 2020
Resolved
A record shall be kept to the satisfaction of the administration and as required by the radio regulations. Chief Mate has not been logging daily checks during the vessels in port dates.
74SOLAS (14CONS) Ch. IV/Reg 17
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 6 October 2019
Resolved
Each completed page of the Garbage Management Book shall be signed by the master of the ship. Entries have not been signed by master since July 2018.
MARPOL (17 Cons.) Annex V/Reg 10.3
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 26 March 2019
Resolved
BEFORE THE SHIP LEAVES PORT AND AT ALL TIMES DURING THE VOYAGE, ALL LIFE SAVING APPLIANCES SHALL BE IN WORKING ORDER AND READY FOR IMMEDIATE USE. RESCUE BOAT ENGINE INOPERABLE.
74 SOLAS (1997) III/19.2
17C/10C
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 13 August 2018
Resolved
0750 - Fire Prevention - "A" class divisions shall be so constructed as to be capable of preventing the passage of smoke and flame. The bulkhead to the purifier room has a small circular penetration forward of the door, a 2 inch semi-circle penetration in the upper aft bulkhead between the engine room and purifier room, and the Switchboard room and the purifier room. 74SOLAS(1997)II-2/3.3.3
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 August 2018
Resolved
0672 - EPIRBs - Every ship shall be provided with a satellite EPIRB capable of floating free if the ship sinks and of being automatically activated when afloat. Vessels EPIRB was fitted with a liferaft hydrostatic release. 74SOLAS(2014)IV/7.1.6.3
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 13 August 2018
Resolved
0750 - Fire Prevention - Doors required to be self-closing shall not be fitted with hold-back hooks. The door to the purifier room was equipped with a hold back hook and was not fitted with a remote release device. 74SOLAS(1997)II-2/47.2
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 13 August 2018
Resolved
1680 - Radio log (Diary) - A record shall be kept, to the satisfaction of the administration as required by the radio regulations. Vessel did not have records of conducting weekly and monthly GMDSS tests. 74SOLAS(2014)IV/17
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 13 August 2018
Resolved
IN ALL SHIPS GENERAL ARRANGEMENT PLANS SHALL BE PERMANENTLY EXIBITED...SHOWING CLEARLY FOR EACH DECK...THE FIRE EXTINGUISHING APPLIANCES...AND THE VENTILATION SYSTEM. CO2 DISCHARGE NOZZLE IN PURIFIER ROOM AND VENTILATION DUCT FROM PURIFIER ROOM ARE NOT IDENTIFIED ON THE PLAN. 74SOLAS(97 CONS) II-2/20.1
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 15 February 2018
Resolved
Oil filtering equipment referred to in this regulation shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. Vessel's oily water separator is inoperable. MARPOL(11 Cons) Annex I Reg 14.6. Action taken 17bc
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 February 2018
Resolved
Electrical installations shall be such that the safety of passengers, crew, and ship from electrical hazards will be ensured. There ae 02 electrical junction boxes with exposed wire and evidence of arcing at the entrance to teh bosun's hold. 74 SOLAS(97 Cons) CH II-I/Reg 40.1.3. Action taken 16bc
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 8 August 2017
Resolved
The master of a vessel equipped with ballast tanks shall not discharge ballast water into waters of the United States. Vessel noted on multiple occasions from January 2017 to date of inspection (08AUG17) that ballast water was discharged into the Miami River.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 31 January 2017
Resolved
0715 -Detection- Any required fixed fire detection system shall be capable of immediate operation. Fire alarm control panel does not detect in zone #7. 74 SOLAS (97 Cons) Ch II-2/Reg 13.1
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 31 January 2017
Resolved
0690 -Line throwing appliance- A line throwing appliance complying with the requirements of regulation 49 shall be provided. The four rockets for the line throwing appliance expired December 2016. 74 SOLAS (97 Cons) Ch III/Reg 17 & 49
Navigation › Piloting/Steering › Marine Charts
Issued 31 January 2017
Resolved
1560 -Charts- Nautical charts and tidal current tables shall be adequate and up to date. Both charts and tidal current tables were out of date. 74 SOLAS (14 Cons) Ch V/Reg 27
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 31 January 2017
Resolved
0100 -Ship's certificates and document- Certificates issued to the vessel shall be readily available and on board for examination at all times. Certificate of Registry, International Tonnage Certificate, ISM-Document of Compliance, and Minimum Safe Manning Certificate were not on board. 74 SOLAS (14 Cons) Ch I/Reg 16
Construction/Loadline › Markings › Summer Load Line
Issued 31 January 2017
Resolved
1220 -Freeboard Marks- The load line letters shall be contrasting color to the hull and permanently marked and plainly visible. Port side markings missing from load line tree. ICLL 66 Annex I, Ch I/Reg 8
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 December 2015
Resolved
Efficient guard rails of bulkwards shall be fitted to all exposed parts of the freeboard and superstructure decks. Port side rail meeting the forcastle is broken.
Engineering › Fuel Oil Storage/Transfer System › Portable Fuel System
Issued 10 December 2015
Resolved
The arrangements for the storage of oil fuel shall be such as to ensure the safety of the ship and persons on board. Multiple buckets of fuel found in the steering gear room.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.