QUEEN CITY BIKE FERRY is a 2015 passenger vessel (inspected). The Coast Guard has recorded 12 inspections since 2016, most recently in May 2026, along with 20 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 21 May 2026.

Built
2015
Last inspected
21 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 May 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH9825
1322703
Flag
UNITED STATES
Maury page id
psix-1322703

Documentation record

Registered dimensions (L × B × D)50.0 ft × 14.0 ft × 3.0 ft
Registered tonnagegross 5 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSIGHTSEER MARINE LLC · HUDSON, FL, UNITED STATES · built 2015
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portBUFFALO, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 12

21 May 2026 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8377933
20 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8139964
25 April 2024 COI Inspection · Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7901441
22 May 2023 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7694557
31 May 2022 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7465241
26 May 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7207055
23 September 2019 Administrative Inspection · Drydock Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6848583
23 May 2019 COI Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6691060
23 May 2018 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6392555
16 May 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6152122
19 September 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6004024
16 May 2016 DAPI Audit · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5878642

Deficiency record · 20

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 20 May 2025 Resolved
Stern light was found inoperable. Repair/replace stern navigation light as required. Prior to operation at night or restricted visibility.
Action required: 705 - Other - as specified
Resolved 9 June 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2025 Resolved
Fuel shutoff valves were not clearly marked. Label fuel shutoff valves to properly identify location of valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2024 Resolved
Ring buoy waterlight was working, but had an expired battery. Replace battery and demonstrate operation to the satisfaction of attending Coast Guard Marine Inspector. 46 CFR 185.726(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 30 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 May 2024 Resolved
Ring buoy perimeter grabline is degregated and fraying. Repair or replace to the satisfaction of attending Coast Guard Marine Inspector. 46 CFR 180.70(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 30 May 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 May 2024 Resolved
Conduct and log man overboard, fire, and abandon ship drills with newly reported crewmembers and every 3 months. Provide Coast Guard Marine Inspector objective evidence (log book) of drills conducted. 46 CFR 185.420& 46 CFR 185.520& 46 CFR 185.524
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2024
Resolved 30 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Means of rescue
Issued 26 May 2021 Resolved
he master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. During drill crew-member working over the water had not donned a life jacket. Add this step to vessel's emergency instructions. Vessel's Master also determined the best side to bring victim to meet EMT would most likely be the "Canalside" side, due to possible quicker response by onshore emergency responders. Add verbiage to emergency instructions stating that (depending on circumstances at the time) bringing a victim to meet onshore first responders may be best done on the Canalside side of the river.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 1 June 2022
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 23 May 2019 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Vessel has defective gangway due to fractured welds. Gangway must be satisfactorily repaired or replaced to the approval of an attending Marine Inspector. A person must be stationed in the immediate proximity of this gangway to monitor the safe arrival and departure of passengers.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2019
Resolved 1 July 2019
Resolution: Made gangway satisfactory
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 May 2018 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. First aid kit contents expired. Replace required contents of first aid kit with unexpired items.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2018
Resolution: Replaced required contents of first aid kit with unexpired items.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 23 May 2018 Resolved
The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Emergency instructions posted did not follow the actual actions of the ship's crew in case of a Man Overboard (MOB). MOB instruction made note of crew member entering water to assist MOB which is unsat. Make posted emergency instructions as to the actual emergency practices of the vessel and drill procedures of the crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2018
Resolution: Posted emergency instructions as to the actual emergency practices of the vessel and drill procedures of the crew.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 May 2018 Resolved
Each floating waterlight must be approved in accordance with §161.010 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.110. Waterlight battery was not changed out ye4arly as per manufacturer. Change waterlight battery and mark with date of install.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2018
Resolution: Changed waterlight battery and marked with date of install.
Documentation › Certificates/Documents › Stability Letter
Issued 23 May 2018 Resolved
The stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2018
Resolution: All pages are now visible, at the operating station of the vessel.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 23 May 2018 Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Vessel has defective gangway due to fractured welds. Gangway is not to be used until adequately repaired. As discussed, use of access to vessel from rear gate can be utilized while fenders are up, allowing the vessel to be brought as close to the pier as possible. A person must be stationed in the immediate proximity of this gangway to monitor the safe arrival and departure of passengers.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2018
Resolution: Gangway repaired satisfactorily.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 23 May 2018 Resolved
Each officer employed on any vessel subject to this subchapter must have his or her license or merchant mariner credential onboard and available for examination at all times when the vessel is operating. MMC's were not onboard for examination. Produce credentials and medical certs for examination.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2018
Resolution: Produced credentials and medical certs for examination.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 May 2016 Resolved
Stencil vessel name on ring buoy.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: Marking applied prior to MI's departure.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 May 2016 Resolved
Water light required by this cite must be secured around the body of the ring buoy.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: Water light correctly attached to ring buoy prior to MI's departure.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 20 May 2016 Resolved
Provide required number of portable lights.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: Additional portable light provided prior to MI's departure.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 20 May 2016 Resolved
Properly mouse anchor shackle.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: Mousing applied prior to MI's departure.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 May 2016 Resolved
Provide required first aid kit.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 20 May 2016
Resolution: New first aid kit provided on board prior to MI's departure.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 May 2016 Resolved
Post all pages of the COI as required by provided cite.
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 27 May 2016
Resolution: All pages posted as required.
Stability › Incline Test › General
Issued 20 May 2016 Resolved
Mark hull with loading mark so that the top of the mark indicates the minimum draft. See stability letter for details on where to mark hull.
Action required: 705 - Other - as specified
Due 27 May 2016
Resolved 27 May 2016
Resolution: Hull marked as required.

Ownership record