← All vessels
BW MONSOON
BW MONSOON is a 2015 tank ship. The Coast Guard has recorded 22 inspections since 2016, most recently in October 2025, along with 9 deficiencies and 2 operational controls.
Records from 2016 to 2025. Most recent: inspection, 28 October 2025.
- Built
- 2015
- Last inspected
- 28 October 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9667564 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7FL8
1322883
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1322883
Inspections, by type
…with no type recorded3
Years with a record
9 calendar years (2016–2025)
The 22 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it53752 - Dead Weight, Metric Ton
73415 - Displacement, Metric Ton
46943 - Convention (Subpart B), Gross Ton
18825 - Convention (Subpart B), Net Ton
73415 - Displacement, Metric Ton
46943 - Convention (Subpart B), Gross Ton
18825 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 22
28 October 2025
PSC B · COC-GAS Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8255570
11 May 2024
PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7908575
6 April 2023
Administrative Inspection · COC-GAS Renew
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7663966
16 September 2021
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7313402
15 September 2021
PSC B · COC-GAS Annual
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7312665
15 September 2021
COE-Administrative
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7313301
12 September 2021
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7313436
11 April 2021
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7173039
30 October 2020
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7087016
15 September 2020
In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7058770
11 September 2020
Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7055832
9 September 2020
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7055920
13 July 2020
COC-GAS Renew · Administrative Inspection · PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7002954
15 June 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6714728
28 September 2018
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6553761
4 September 2018
ISPS II Exam · Ballast Water Examination · COC-GAS Annual
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6530884
25 June 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6455129
16 November 2017
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6307915
12 September 2017
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6265184
4 August 2017
Ballast Water Examination · COC-GAS Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6221387
29 March 2016
ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5838953
29 March 2016
Special
Type not classified · Liquefied Gas Carrier National Center of Expertise · Activity 5925705
Deficiency record · 9
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 September 2021
Resolved
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. VESSEL REPORTED MAIN ENGINE FAILURE DUE TO LOSS OF LUBE OIL PRESSURE. VESSEL MUST PROVIDE A CLASS REPORT WITH A CAUSAL ANALYSIS OF THE FAILURE OF MAIN ENGINE AND COMPLETION OF REPAIRS PRIOR TO MOVEMENT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 September 2020
Resolved
13101: The condition of the ship and equipment shall be maintained t oconform with provisions of the present regulations to ensure the ship will remain fit to proceed to sea.
The vessle experienced an equipment failure to the main propulsion engine, due to water ingress t othe lube oil sump, while transitting en route to Houston Ship Channel. Submit for review a class report attesting t othe cause of the failure, that authroized temporary or permanent repairs have been completed, and that the vessel's full and normal maneuverability has been restored. 74SOLAS14 I/11 17ac
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2019
Resolved
The machinery shall be of a design and construction adequate for the service for which they ae intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to...other hazards.
the vessel experienced an equipment failure while along side Targa Dock #5 on water of the United States which Adversely affected its maneuverability and posed a hazard to vessels and infrastructure along the Houston Ship Channel.
74 SOLAS (14) II-1/26
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 September 2018
Resolved
08199- ALARMS (OTHER)- AN AUDIBLE AND VISUAL ALARM SYSTEM TO GIVE A WARNING ON BOTH SIDES OF THE AIRLOCK SHOULD BE PROVIDED TO INDICATE IF MORE THAN ONE DOOR IS MOVED FROM THE CLOSED POSITION; OUTSIDE ALARM ON MOTOR ROOM AIRLOCK INOPERABLE/NOT INSTALLED. 93 IGC 3.6.3.
01 - Certificates & Documentation › 011 - Ships Certificates › Liquefied Gases in Bulk (ICoF/IGC Code)
Issued 4 September 2018
Resolved
01112-LIQUEFIED GASES IN BULK (ICOF/IGC CODE)- PRESSURE RELIEF VALVES SHOULD BE SET AND SEALED BY A COMPETENT AUTHORITY ACCEPTABLE TO THE ADMINISTRATION AND A RECORD OF THIS ACTION, INCLUDING THE VALVES OF SET PRESSURE, SHOULD BE RETAINED ON BOARD THE SHIP; SET AND SEAL CERTIFICATE NO. KOB1321226 ISSUED BY LLOYDS REGISTER ISSUED 20 OCTOBER 2013 LISTS SERIAL NUMBERS FOR VLAVES A TO H, HOWEVER SERIAL NUMBERS ON VALVES F-H INSTALLED DO NOT MATCH CERTIFICATE. NO INDICATION SET PIECES HAVE BEEN TAMPERED WITH.
Operations/Management › Ballast Water Managment › Alternative Management Method
Issued 4 August 2017
Resolved
Installed AMS system inoperable since March 2017. 33 CFR 151.2035(a).
Operations/Management › Ballast Water Managment › Alternative Management Method
Issued 4 August 2017
Resolved
Ballast Water Management Plan doesn't include all necessary provisions stated in 33CFR151 Subpart D / 33CFR151.2050(g)
Deck/Cargo › Vapor Control Systems › Vessel Vapor Overpressure/Vacuum Protection
Issued 4 August 2017
Resolved
Cargo vapor main mast riser distance is less than 25M of nearest air intake vent of compressor motor room. SOLAS(14) VII/13; IGC (93)8.2.10
Electrical › Lighting (service) › Lighting Fixture
Issued 4 August 2017
Resolved
Identified condensation within light fixture lens difuser on NR.1 COT. SOLAS(14)VII/13; IGC code(93)/10.1.5.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.