AQUAKATANA

AQUAKATANA is a 2005 freight ship. The Coast Guard has recorded 3 inspections since 2016, most recently in July 2021, along with 5 deficiencies.

Records from 2016 to 2021. Most recent: inspection, 15 July 2021.

Built
2005
Last inspected
15 July 2021
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 July 2021
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2021)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9333797
1323249
Flag
PANAMA
Maury page id
psix-1323249

Documentation record

Tonnage as PSIX records it185897 - Dead Weight, Ton
207952 - Displacement, Ton
92993 - Convention (Subpart B), Gross Ton
61795 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 3

15 July 2021 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7256721
23 November 2016 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6046501
25 April 2016 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5861942

Deficiency record · 5

Engineering › Steering Gear System › Pump
Issued 25 April 2016 Resolved
0936 - Number 1 steering pump is inoperable. crew tested it multiple times in follow up and non follow up modes in front of PSCO and it never worked. Emergency steering test was conducted and local controls were not working. 74 SOLAS 04 II-1/29.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2016
Resolution: Received, reviewed and accepted class report
Lifesaving › Immersion Suits › General
Issued 25 April 2016 Resolved
0663 -Personal lights for the immersions suits were found expired in the lifeboats, engine control room, and in two crew cabins. 2 lights were found satisfactory in the bridge. 29 of 31 immersion suite lights were expired. 74 SOLAS 14 III/34
Action required: 15 - Rectify deficiencies by next port
Resolved 23 November 2016
Resolution: Reviewed class report attesting to repairs, SAT.
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 25 April 2016 Resolved
0715 - Testing of smoke and heat detectors through the engine room are being done with cigarette smoke and lighters. review of their annual testing of detectors IAW SMS is inconsistent in the records and does not allow for periodic testing of detectors. Class to review SMS testing schedule of smoke, heat, and flame detectors. 74 SOLAS 14 II-2 7.3.2
Action required: 705 - Other - as specified
Due 29 May 2016
Resolved 23 November 2016
Resolution: Reviewed class report attesting to repairs, SAT.
Electrical › Lighting (service) › Ground Detection
Issued 25 April 2016 Resolved
0950 - PSCO observed multiple electrical safety hazards in the BOSUN Store in way of lighting distribution cabinets on the port side; new cable run in the overhead had plastic supports, temporary cable connections were found in multiple places, and cracked insulation with exposed wire on a grounding cable from the battery charging station. 74 SOLAS 04 II-1 / 40.1.3
Action required: 705 - Other - as specified
Due 29 May 2016
Resolved 23 November 2016
Resolution: Reviewed class report attesting to repairs, SAT.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 25 April 2016 Resolved
0720 - Portable fire extinguisher cabinet outside of paint locker was found to be rusted shut. upon further inspection and entry the fire extinguisher inside had not been inspected since December of 2015. 74 SOLAS 14 II-2 / 14.1.1.1
Due 29 April 2016
Resolved 29 April 2016
Resolution: Corrected on the spot.