MAURY USCG vessel records
← All vessels

SHIKOKU ISLAND

SHIKOKU ISLAND is a 2014 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in April 2022, along with 2 deficiencies.

Records from 2016 to 2022. Most recent: inspection, 24 April 2022.

Built
2014
Last inspected
24 April 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 24 April 2022
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9711901
1323282
Flag
PANAMA
Maury page id
psix-1323282

Documentation record

Tonnage as PSIX records it21168 - Convention (Subpart B), Gross Ton
33443 - Dead Weight, Ton
40698 - Displacement, Ton
10765 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 10

24 April 2022 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7437567
20 April 2022 COE-Administrative
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7434617
27 October 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7340546
20 October 2021 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7330748
16 October 2018 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6563190
10 October 2018 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6555608
27 October 2017 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6296239
3 October 2017 Random ISPS/MTSA/PSC · NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6280329
19 February 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6089917
2 May 2016 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5856950

Deficiency record · 2

Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 3 October 2017 Resolved
0715 - Detection - The function of fixed fire detection and fire alarm systems shall be periodically tesed to the satisfaction of the Administration by means of equipment producing hot air at the appropriate temperature, or smoke or aerosol particles having the appropriate range of density or particle size, or other phenomena associated with incipient fires to which the detector is designed to respond. Vessel does not have appropriate means of testing the heat detection system. SOLAS 74 (2014) CH II-2 Reg 7.3.2
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 4 October 2017
Resolved 27 October 2017
Resolution: Class report provided along with photos indicating that proper heat detectors were provided.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 3 October 2017 Resolved
0799 - Other (Fire fighting Equipment) - Fire Control Plans and Booklet shall be kept up to date. Current Fire Control Plans on board do not list additional fire fighting appliances for helideck. SOLAS 74 (2014 Cons Ed) CH II-2 Reg 15.2.4.1
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 November 2017
Resolved 27 October 2017
Resolution: Class report and photos show that the fire control plans have been updated.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.