← All vessels
LIGHTNING
Industrial Vessel · Miscellaneous Vessel class · Built 2010s · USCG Heartland District (CGD-H) · Other hulls named LIGHTNING
LIGHTNING is a 2015 industrial vessel. The Coast Guard has recorded 11 inspections since 2016, most recently in August 2025, along with 2 deficiencies.
Records from 2016 to 2025. Most recent: inspection, 5 August 2025.
- Built
- 2015
- Last inspected
- 5 August 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 2 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1260640
9690389 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDI2266
1323932
Flag
UNITED STATES
369533000
Maury page id
psix-1323932
Inspections, by type
The 11 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.
Documentation record
Registered dimensions (L × B × D)236.2 ft × 60.0 ft × 25.3 ft
Registered tonnagegross 3,641 / net 1,177
ITC dimensions (L × B × D)236.2 ft × 60.0 ft × 25.3 ft
ITC tonnagegross 3,641 / net 1,177
BuilderBAE SYSTEMS SOUTHEAST SHIPYARDS JACKSONVILLE LLC · JACKSONVILLE, FL, UNITED STATES · built 2015
Hull materialSteel
PropulsionElectric Motor
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3641 - Convention (Subpart B), Gross Ton
1177 - Convention (Subpart B), Net Ton
1177 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDI2266MMSI 369533000 · active · compulsorily equipped · granted 1 May 2025, expires 4 June 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
5 August 2025
Re-Inspection · Administrative Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8203298
20 September 2024
ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8006183
7 August 2023
Periodic Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7762088
13 September 2022
Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7558267
28 September 2021
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7322021
29 July 2020
ACP COI Oversight · COI Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7019193
7 August 2019
Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6775509
16 October 2018
Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6562144
24 January 2018
Administrative Inspection
Administrative · Commandant (CG-ENG) · Activity 6343003
19 October 2017
MTSA/ISPS Verification · Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6291795
18 October 2016
ACP Annual Oversight · Annual Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6025121
Deficiency record · 2
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 August 2019
Resolved
Fuel vent outlets on the port fuel overfill, starboard fuel overfill, and #3 port fuel vent are all single screen 20 by 20 mesh. Replace mesh with approved single 30 by 30 mesh or two 20 by 20 mesh screens.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 August 2019
Resolved
Identified loose electrical wiring on the port side main deck light located directly aft of the gangway. Make repair to ensure electrical wiring is intrinsically safe.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.