MAURY USCG vessel records
← All vessels

LIGHTNING

LIGHTNING is a 2015 industrial vessel. The Coast Guard has recorded 11 inspections since 2016, most recently in August 2025, along with 2 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 5 August 2025.

Built
2015
Last inspected
5 August 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 5 August 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9690389
WDI2266
1323932
Flag
UNITED STATES
Maury page id
psix-1323932

Documentation record

Registered dimensions (L × B × D)236.2 ft × 60.0 ft × 25.3 ft
Registered tonnagegross 3,641 / net 1,177
ITC dimensions (L × B × D)236.2 ft × 60.0 ft × 25.3 ft
ITC tonnagegross 3,641 / net 1,177
BuilderBAE SYSTEMS SOUTHEAST SHIPYARDS JACKSONVILLE LLC · JACKSONVILLE, FL, UNITED STATES · built 2015
Hull materialSteel
PropulsionElectric Motor
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it3641 - Convention (Subpart B), Gross Ton
1177 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 11

5 August 2025 Re-Inspection · Administrative Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8203298
20 September 2024 ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8006183
7 August 2023 Periodic Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7762088
13 September 2022 Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7558267
28 September 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7322021
29 July 2020 ACP COI Oversight · COI Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7019193
7 August 2019 Administrative Inspection · Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6775509
16 October 2018 Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6562144
24 January 2018 Administrative Inspection
Administrative · Commandant (CG-ENG) · Activity 6343003
19 October 2017 MTSA/ISPS Verification · Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6291795
18 October 2016 ACP Annual Oversight · Annual Inspection · Administrative Inspection · MTSA/ISPS Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6025121

Deficiency record · 2

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 August 2019 Resolved
Fuel vent outlets on the port fuel overfill, starboard fuel overfill, and #3 port fuel vent are all single screen 20 by 20 mesh. Replace mesh with approved single 30 by 30 mesh or two 20 by 20 mesh screens.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 12 August 2019
Resolution: Cleared by ABS.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 August 2019 Resolved
Identified loose electrical wiring on the port side main deck light located directly aft of the gangway. Make repair to ensure electrical wiring is intrinsically safe.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 August 2019
Resolved 12 August 2019
Resolution: Cleared by ABS.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.