Records from 2016 to 2026. Most recent: inspection, 16 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
16 April 2026
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8345582
10 March 2025
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8091251
3 December 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8042249
14 May 2024
Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7911588
17 January 2024
Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7850668
23 May 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7702131
19 October 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7573476
16 May 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7459093
13 May 2021
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7199495
16 December 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7113916
15 April 2020
Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6939729
2 December 2019
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6865507
16 May 2019
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6686706
28 November 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6588755
15 May 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6415452
8 May 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6136573
17 March 2017
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6105667
10 May 2016
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5874307
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 16 April 2026
Resolved
At each inspection for certification and at every other vessel inspection, quarters, toilet and washing spaces, galleys, serving pantries, lockers, and similar spaces may be examined to determine that they are serviceable and in a sanitary condition. MI observed black mold in two wooden containers used for storage of 16 adult lifejackets. Possible mold observed on lifejackets as well. O/o to clean and treat affected areas and lifejackets to the satisfaction of the MI.
46 CFR 176.818
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 April 2026
Resolution: Moldy boxes removed. Area disinfected. New boxes installed. The mold issue has been satisfactorily addressed. The BlackFish III is no longer restricted to the pier.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 April 2026
Resolved
A hatch exposed to the weather must be watertight. Vessel had multiple weather deck hatch/covers where the gasket material was worn down enough to allow down-flooding into spaces/voids. O/o must replace/repair all the gasket material throughout the vessel to ensure watertight integrity.
46 CFR179.360(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 1 May 2026
Resolution: O/o replaced all the gasket material throughout the vessel.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 April 2026
Resolved
...visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: […] a bilge well. Audible alarm for high water levels did not function.
46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 1 May 2026
Resolution: Audible alarm for high water levels was repaired and is functioning satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 16 April 2026
Resolved
Each lifefloat must be equipped with [...] a light. One of the three lights for the life floats was not working at the time of inspection. Vessel restricted to daytime operations.
46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 1 May 2026
Resolution: Battery was replaced for the life float light. Light is functioning satisfactorily.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 April 2026
Resolved
Drug testing programs required by this part must be conducted in accordance with 49 CFR part 40, Procedures for Transportation Workplace Testing Programs. No documents provided demonstrating compliance upon request.
46 CFR 16.113(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 22 April 2026
Resolution: Proof of enrollment in a drug and alcohol testing program was satisfied.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 April 2026
Resolved
The owner, charter, master or managing operator shall instruct each crew member [...] at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Crew training shall be logged or otherwise documented for review
MI noted only one crew training upon review of nine months of logs.
46 CFR 185.420(a) & (d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 22 April 2026
Resolution: Crew Training Logbook in place. Inspectors will verify compliance at next annual exam.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 16 April 2026
Resolved
The following tests and inspections must be carried out weekly on a vessel: Each survival craft [...] must be visually inspected to ensure its readiness. Weekly inspections not logged/available for review upon request.
46 CFR 185.720
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 22 April 2026
Resolution: Surival gear inspection schedule in place. Inspectors will verify compliance at next annual exam.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 April 2026
Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA as amended here: Monthly inspections [...] may be conducted by the owner, operator, person-in-charge, or a designated member of the crew; and (iv) The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. No monthly inspection of portable extinguishers available at time of inspection.
46 CFR 176.810(b)(1)(ii) and (iv)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 1 May 2026
Resolution: Managing operator provided satisfactory evidence of the required servicing.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 April 2026
Resolved
First-aid kit. Each first-aid kit must meet the requirements in ISO 18813:2006(e). Kit missing several items.
46 CFR 184.710
46 CFR 199.175(b)(10)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 1 May 2026
Resolution: Proof of first aid kit meeting the requirements of ISO 18813:2006(e) was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 April 2026
Resolved
A vessel on a lakes, bays, and sounds…route must carry three hand red flare distress signals; and three hand orange smoke distress signals. No distress signals available for inspection. Vessel restricted to daytime operations.
46 CFR 180.68(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 22 April 2026
Resolution: Flares were purchased and insatlled onboard the vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 April 2026
Resolved
A vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication; Coast Guard Light List; Tide tables; and Current Tables. Vessel’s charts and publications were not up-to-date.
46 CFR 184.420(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 1 May 2026
Resolution: Operator provided proof of up to date charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication; Coast Guard Light List; Tide tables; and Current Tables.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 April 2026
Resolved
Each lifejacket carried on board the vessel be marked in accordance with 85.604 of this vessel. 03 child lifejackets were not labeled with vessel name.
46 CFR 180.7
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2026
Resolved 1 May 2026
Resolution: Operator labelled all chidlren's lifejackets.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 18 March 2025
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. O/o is to post signage indicating max number of passengers on upper deck.
46 CFR 185.602(g)
Action required: 10 - Deficiency Rectified
Due 18 March 2025
Resolved 18 March 2025
Resolution: O/o Posted sign displaying max amount of passengers allowed on updder deck.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 March 2025
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The arrangement of the retroreflective material applied after March 11, 1996, must be as specified by IMO Resolution A.658(16). O/o is to replace missing retroreflective material on ring life buoy located on the aft deck.
46 CFR 185.604(i)
Action required: 10 - Deficiency Rectified
Due 18 March 2025
Resolved 18 March 2025
Resolution: O/o replaced missing retroreflective material.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 May 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Marine inspector observed expired aspirin to be in the first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 24 May 2024
Resolution: Purchased new aspirin.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must: Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Marine inspector observed life line attached to ring buoy on upper deck, aft to be deteriorated by ultraviolet light.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2024
Resolved 24 May 2024
Resolution: Replaced Line.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 14 May 2024
Resolved
The light must be a floating waterlight approved under approval series 161.010 or other standard specified by the Commandant. The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Marine inspector observed lanyard attaching floating waterlight to a life float to be deteriorated by ultraviolet light.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 24 May 2024
Resolution: Replaced Line.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 14 May 2024
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline. Vessel representative notified marine inspector of the port aft high water level alarm being inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2024
Resolved 28 May 2024
Resolution: replaced alarm.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 May 2022
Resolved
Port outboard emergency fuel shutoff valve handle was missing. Permanently repair/replace valve handle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2022
Resolved 6 June 2022
Resolution: Operator showed picture proof of deficiencies being rectified.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2021
Resolved
The first aid kit contained expired items and was not approved IAW 46CFR184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 28 May 2021
Resolution: New kit obtained.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 16 December 2020
Resolved
The 3 life floats were not marked with vessel's name. Vessel's name needs to be marked on life floats. 46CFR185.604
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 April 2021
Resolved 1 March 2021
Resolution: Vessel's have been marked properly.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 May 2019
Resolved
Vessel missing 01 fire bucket. Provide at least three 2.5 gal buckets with attached lanyard. The words fire bucket must be stenciled in a contrasting color on each bucket. 46CFR181.610.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 15 April 2020
Resolution: Vessel provided three 2.5 gal buckets with attached lanyard. The words fire bucket were stenciled in a contrasting color on each bucket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 May 2019
Resolved
Batteries expired in life buoy lights. Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery is passed. 46CFR185.726(d).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 May 2019
Resolved 15 April 2020
Resolution: Batteries were renewed Feb 2020 in life buoy lights.