Records from 2016 to 2026. Most recent: inspection, 15 June 2026.
Documentation record
Registered dimensions (L × B × D)95.8 ft × 22.0 ft × 9.5 ft
Registered tonnagegross 95 / net 64
ITC dimensions (L × B × D)95.8 ft × 22.0 ft × 9.5 ft
ITC tonnagegross 171 / net 58
BuilderSCARANO BOAT BUILDING INC · ALBANY, NY, UNITED STATES · built 2015
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
171 - Convention (Subpart B), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
58 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
15 June 2026
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8402995
10 June 2025
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8151698
28 January 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8071002
22 May 2024
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7917152
23 May 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7837362
8 March 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7648110
11 May 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7449977
10 November 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7348858
27 July 2021
In-Service Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7269853
18 March 2021
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7156228
31 August 2020
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7048244
11 August 2020
Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7025460
17 September 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6813750
10 June 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6709237
26 March 2019
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6651253
29 October 2018
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6570051
8 November 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6339577
27 March 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6117602
26 October 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6029806
20 July 2016
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5962187
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 June 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with
energized parts. Dead end wire found next to VHF radio at the operating station. Remove or cap off wire.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 29 June 2026
Resolution: Operator sent photo of capped off wire.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 15 June 2026
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. MI observed excessive accumulation of oily rags and other storage in engine room and void aft of engine room. Remove oily rags and storage that might create a fire hazard, clog bilge pumping systems, or block emergency escapes.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 29 June 2026
Resolution: Operator sent photos of engine room and lazarette. Spaces were cleaned, debris cleared, and bilge pick ups clear of debris.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 June 2026
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. MI observed chiller leak. Fix leak to the satisfaction of MI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 June 2026
Resolved 29 June 2026
Resolution: Operator reported corroded hose clamp that was replaced with new clamp.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 June 2025
Resolved
The following spaces must be equipped with a fire detection and alarm system of an approved type installed in accordance with 46 CFR part 76. (1) A space containing propulsion machinery.
Vessel's heat detector in the Engine Room is recalled IAW Marine Safety Alert 12-25. Replace detector with approved type.
46 CFR 181.405
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 September 2025
Resolution: Vessel replaced recalled heat detector.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 22 May 2024
Resolved
The following spaces must be equipped with a fire detection and alarm system installed in accordance with 46 CFR... Capable of automatic discharge upon heat detector activation. Engine room has two heat detectors, AFT heat detectors was found damaged.
46 CFR 181.405 a
Action required: 705 - Other - as specified
Due 29 May 2024
Resolved 30 May 2024
Resolution: Vessel submitted electroic report attesting to the appropriate repairs of the heat detector, to include proper operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 July 2021
Resolved
THE OWNER OR MANAGING OPERATOR SHALL SUBMIT DRAWINGS, SKETCHES, OR WRITTEN SPECIFICATIONS DESCRIBING THE DETAILS OF ANY PROPOSED ALTERATIONS TO THE COGNIZANT [name withheld] MUST BE APPROVED BY THE [name withheld] IS STARTED. MI DISCOVERED THAT A 6-8 FT STRETCH OF RAILING LOCATED ON THE FWD STBD CENTERLINE WAS MISSING/REPLACED WITH LINE WITHOUT THE APPROVAL BY THE [name withheld] A REPAIR PLAN ALONG WITH CONSTANT COMMUNICATION WITH CG MARINE INSPECTORS TO ENSURE THAT THERE IS CG OVERSIGHT FOR THE ENTIRE REPAIR PROCESS. VESSEL MUST REPAIR THE RAILING TO THE SATISFACTION OF THE OCMI PRIOR TO THE CARRIAGE OF PASSENGERS.
46 CFR 176.700
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2021
Resolution: Operator sent photographs of authorized repairs toward damaged railing. Deficiency is cleared; vessel is allowed to carry passengers.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 11 August 2020
Resolved
All electrical connections shall be made in an enclosure. Bilge hi-water alarm connections and low voltage panel found underneath stairwell require covering.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 13 August 2020
Resolution: Vessel representative provided photo evidence attesting to repairs made.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 11 August 2020
Resolved
Cracked window near mid-body, port side, in overheard. To be fixed at dry dock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 11 August 2020
Resolved 18 March 2021
Resolution: Window meets the intent of requlation.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 August 2020
Resolved
Fuel oil cut off valves shall be labeled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2020
Resolved 13 August 2020
Resolution: Vessel representative provided photo evidence attesting to repairs made.
04 - Emergency Systems › N/A - No Subsystem › Emergency fire pump and its pipes
Issued 29 October 2018
Resolved
Arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. When tasked with pumping out the bilge space and operating the fire pump, the master had difficulty troubleshooting issues with the system. The master of the vessel must show proficiency in the operation and troubleshooting of the bilge/fire pump system.
Action required: 705 - Other - as specified
Due 5 November 2018
Resolved 5 November 2018
Resolution: Witnessed master operate the bilge and fire pump system without issue, noted new operation card for system that included additional troubleshooting for system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 October 2018
Resolved
Arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Old oily pads and oil filled buckets must be removed from the engine room and residue cleaned up.
Action required: 705 - Other - as specified
Due 5 November 2018
Resolved 5 November 2018
Resolution: Examined engine room, oily pads and buckets were removed and bilges cleaned.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 October 2018
Resolved
The alcohol testing of each individual must be conducted within 2 hours of when the SMI occurred, unless precluded by safety concerns directly related to the incident. Vessel's alcohol test strips are expired.
Action required: 705 - Other - as specified
Due 5 November 2018
Resolved 30 October 2018
Resolution: Received photographic evidence of purchased alcohol strips.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 October 2018
Resolved
A vessel must carry a first aid kit approved under approval series 160.041 or an equivalent kit. Several items in the kit were expired and must be replaced.
Action required: 705 - Other - as specified
Due 5 November 2018
Resolved 30 October 2018
Resolution: Received photographic evidence of purchased items for first aid kit.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 26 October 2016
Resolved
Provide FCC safety certificate.
Action required: 705 - Other - as specified
Due 2 November 2016
Resolved 1 November 2016
Resolution: The operator provided a copy of the FCC saftety certificate with an expiration date of 07AUG2020.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 26 October 2016
Resolved
Replace electrical clamps.
Due 2 November 2016
Resolved 1 November 2016
Resolution: Received photographs from owner attesting to proper replacement of electrical clamps.