MAURY USCG vessel records
← All vessels

JUAN DIEGO

JUAN DIEGO is a 1999 freight ship. The Coast Guard has recorded 52 inspections since 2016, most recently in August 2026, along with 11 deficiencies — 1 with no resolution recorded — and 8 operational controls.

Records from 2016 to 2026. Most recent: inspection, 6 August 2026.

Built
1999
Last inspected
6 August 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 6 August 2026
…with no type recorded10
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9189574
1324379
Flag
CYPRUS
Maury page id
psix-1324379

Documentation record

Tonnage as PSIX records it4818 - Dead Weight, Metric Ton
6599 - Displacement, Metric Ton
2988 - Convention (Subpart B), Gross Ton
1311 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

ATHENA Towing Vessel · MISLE 1224364 · 15 February 2017 · activity 6104595

Inspection history · 52

6 August 2026 PSC A
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8455025
8 February 2026 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8305902
29 July 2025 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8196919
21 May 2025 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8140595
9 May 2025 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8132013
27 March 2025 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8100855
12 February 2025 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8077286
13 August 2024 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7977697
13 February 2024 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7864259
24 August 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7776048
1 August 2023 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7753725
28 January 2023 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7626691
4 August 2022 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7522738
19 June 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7481581
2 June 2022 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7466151
3 May 2022 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7443361
5 April 2022 Administrative Inspection · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7425114
28 March 2022 In-Service Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7419831
4 February 2022 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7386099
11 September 2021 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7310143
4 September 2021 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7303291
2 September 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7302718
20 August 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7292300
12 August 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7284760
11 August 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7284031
26 July 2021 PSC A
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7268186
24 July 2021 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7266512
12 February 2021 PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7138617
11 August 2020 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7029847
16 June 2020 PSC B
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6977299
24 May 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6959062
24 May 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6959086
28 October 2019 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6840526
22 April 2019 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6667415
31 October 2018 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6572394
15 October 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6559348
21 September 2018 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6545657
22 August 2018 Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6519453
6 March 2018 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6364257
20 February 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6357753
24 November 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6312046
6 October 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6282915
21 September 2017 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6271503
17 August 2017 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6243919
14 August 2017 Ballast Water Examination · PII Safety Exam · ISPS II Exam · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6240216
15 July 2017 ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6209619
24 May 2017 In-Service Inspection · ISPS III Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6154148
15 February 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6088564
15 February 2017 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6104595
13 February 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6087229
5 October 2016 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6014581
14 April 2016 PII Safety Exam · ISPS III Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5853982

Deficiency record · 11

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 6 August 2026 No resolution recorded
PSCO identified spliced wiring in multiple locations throughout the machinery space and steering space.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 21 May 2025 Resolved
13199 - Other (machinery) The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on board. PSCO observed corrosion on cooling water piping, resulting in leakage of water through a 1/2 inch hole. 74 SOLAS (2004) CH. II-1/ Reg 26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2025
Resolution: Vessel installed new piping and fittings.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 March 2022 Resolved
Company should establish procedures to ensure the ship is maintained in conformity with provisions and relevant rules and regulations. In meeeting these requirements the company should ensure that inspections are held at appropriate intervals. PSCO observed eyelets on the bracket for the gangway ladder were rusted through and failed under normal use. The monthly maintenenance checks showed it was checked one month ago and did not rust in that short of time. Recommend class Audit within next 3 months. 74SOLAS(20) IX/3.1 ISM CODE 10.2.1 705c WITHIN 90 DAYS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 June 2022
Resolved 2 June 2022
Resolution: ISM Audit conducted by Class and submitted to local USCG Office by Company's Port Captain.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 28 March 2022 Resolved
MEANS SHALL BE PROVIDED TO ENSURE SAFE, CONVENIENT AND UNOBSTRUCTED PASSAGE FOR ANY PERSON EMBARKING ON, OR DISEMBARKING FROM ANY ACCOMMODATION LADDDER OR OTHER APPLIANCE. PSCO OBSERVED BRACKETS FOR GANGWAY LADDER RUSTED THROUGH ANF BROKE OFF. 74SOLAS(20)V/24.4 40ac
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 April 2022
Resolved 5 April 2022
Resolution: Damaged brackets were removed and replaced in kind. Load test conducted after installation to 1400 lbs and all found satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 October 2018 Resolved
Code 0660 Each Lifejacket shall have a luminous intensity of not less than 0.75 cd. PSCO observed 04 lifejackets lights that were inoperable one to internal corrosion. Cite 74 SOLAS (97cons) III/32.3 Action taken 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 October 2018
Resolution: Inspected and found corrected
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 15 October 2018 Resolved
Code 2550 The Company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the Company. PSCO observed 04 lifejackets with inoperable lights. Additionaly no SMS procedures for the inspection of lifejacket lights are implemented. Cite 74 SOLAS (2014 cons) IX/3.1 ISM CODE Part A 10.1 Action taken 50c
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 October 2018
Resolution: Inspected and found corrected
07 - Fire Safety › N/A - No Subsystem › International shore-connection
Issued 15 October 2018 Resolved
Code 0720 Ships of 500 gross tonnage and upwards shall be provided with at least one international shore connection. PSCO observed international shore connection kit was missing parts to include gasket. Cite 74 SOLAS (97cons) II-2/19.1 Action taken 10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 31 October 2018
Resolution: Inspected and found corrected
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 February 2018 Resolved
1730 After any survey of the ship under regulations 7,8,9, or 10 has been completed, no change shall be made in the structural arrangements, machinery, equitment and other items covered by the survey, without the sanction of the administration. The OWS effluent overboard discharge piping has a ball valve installed that is not displayed on class approved drawing. 50AC
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 1 March 2018
Resolution: Received class approved bilge drawing showing ball valve installed on OWS piping
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 14 August 2017 Resolved
2035: "A" CLASS DIVISION SHALL BE CAPABLE OF PREVENTING SMOKE AND FLAME FOR ONE HOUR. A 2X2 INCH HOLE PENETRATION THROUGH CLASS "A" BOUNDARY LOCATED ABOVE EMERGENCY ESCAPE STBD SIDE ENGINE ROOM LOWER DECK. SOLAS CONS. 97 CH. 11-2 Reg 3.3.3 / 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2017
Resolution: Classification society was notified of issue at time of inspection. Butt splice fitted and welded in place.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 14 August 2017 Resolved
1160: THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFOMR WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITH OUT DANGER TO THE SHIP OR PERSONS ONBOARD. CARGO HATCHES ARE UNABLE TO OPEN DUE TO HYDRAULIC PUMP COUPLING FAILURE. SOLAS CONS. 09 CH. I Reg. 11 / 17C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2017
Resolution: Couplings for hydraulic pumps replaced.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 14 August 2017 Resolved
0950: ELECTRICAL INSTALLATIONS SHALL BE SUCH THAT THE SAFETY OF PASSENGERS, CREW, AND SHIP FROM ELECTRICAL HAZARDS IS ENSURED. A PORTABLE FAN WAS LASHED IN THE PASSAGE WAY ADJACENT FROM THE A.C. PUMP LOCATED IN THE ENGINE ROOM. SOLAS CONS. 97 CH II-1 Reg. 40.1.3 / 10C
Due 14 August 2017
Resolved 14 August 2017
Resolution: PORTABLE FAN REMOVED. DEFICIENCY CLEARED ON THE SPOT.

Ownership record