Records in 2017. Most recent: inspection, 29 November 2017.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 17 November 2017
Resolved
A fireman's outfit shall consist of a breathing apparatus, a lifeline, a safety lamp and an axe. The jacket to one of the fireman's outfits had a defective button which did not allow full closure and protection during the drill. SOLAS 60 II/63(a). 17.c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2017
Resolution: Firemans outfit was taken out of service.
Construction/Loadline › Hull › Hull Plating
Issued 15 November 2017
Resolved
The administration shall satisfy itself that the general structural strength of the hull is sufficient for the drought corresponding to the freeboard assigned. On the port and starboard quarters, several doubler plates were found. There is no indication that class is aware of or can attest to the structural integrity of the modifications. ICLL(66)I/1. 16ac
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 19 November 2017
Resolution: Addressed by class to the satisfaction of Coast Guard
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 15 November 2017
Resolved
Oil filtering equipment shall be of a design approved by the administration. A PVC pipe modification had been made which was not reflected in approved manual and systems. MARPOL I/14.6
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 19 November 2017
Resolution: Addressed by class to the satisfaction of Coast Guard
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 15 November 2017
Resolved
Cargo ships of less than 5,000 gt there shall be a self contained emergency source of power located to the satisfaction of the administration. The emergency diesel generator automatic ventilation had a modification to its source of power. SOLAS(60)II/26(b)(i). 15ac
Action required: 15 - Rectify deficiencies by next port
Resolved 19 November 2017
Resolution: Addressed by class to the satisfaction of Coast Guard
Fire Fighting › Fire Pumps › Arrangement
Issued 15 November 2017
Resolved
The administration shall ensure that the hull, machinery, and equipment is in all respects satisfactory to conditions after survey. An exhaust leak was found on the emergency fire pump exhaust piping. SOLAS(60)I/11
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 19 November 2017
Resolution: Addressed by class to the satisfaction of Coast Guard
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 15 November 2017
Resolved
Each transfer pipe system must not leak under static liquid pressure at least 1.5 times the max allowable working pressure. Vessel had not conducted hydrostatic pressure testing on bunkering lines. Vessel cannot conduct bunker ops in U.S. waters until testing has been satisfactorily completed. 33CFR156.170(c)(4). 17.c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 November 2017
Resolution: Addressed by class to the satisfaction of Coast Guard
Electrical › Electrical Distribution System (service) › Switchboard
Issued 15 November 2017
Resolved
Electrical installations shall be such that the safety of the crew and ship from electrical hazards will be assured. Overhead condensate drain above electrical panel in engine control room is electrical/safety hazard. SOLAS60 II/23(a)(ii)
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 19 November 2017
Resolution: Addressed by class to the satisfaction of Coast Guard
Electrical › Electrical Distribution System (service) › Panelboard
Issued 15 November 2017
Resolved
Electrical installations shall be such that the safety of the crew and ship from electrical hazards will be assured. Engine control room distribution panel was modified with wood panels creating an unsafe fire hazard. SOLAS60 II/23(a)(ii). 16ac
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 29 November 2017
Resolution: Removed wood panels and replaced with aluminum panels.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 15 November 2017
Resolved
Electrical installations shall be such that the safety of the crew and ship from electrical hazards will be assured. Vessel had excess open electrical wiring in steering and engine room. SOLAS60 II/23(a)(ii). 16.a.c
Action required: 705 - Other - as specified
Due 29 November 2017
Resolved 19 November 2017
Resolution: Addressed by class to the satisfaction of Coast Guard
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 November 2017
Resolved
Drills shall as far as practicable be conducted as if there were an actual emergency. Abandon ship and fire drills postponed until prior to vessel departure. SOLAS2014 III/19.3 17.C
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 November 2017
Resolution: A satisafactory fire and abandon ship drill were witnessed.