Records from 2017 to 2020. Most recent: inspection, 21 December 2020.
Inspection history · 5
21 December 2020
In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7114571
18 December 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7113923
18 December 2020
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7117480
15 December 2020
PSC B · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7111970
16 February 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6089939
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 15 December 2020
Resolved
11101 - The propeller shafting shall be so arranged that the propeller can be disengaged from the engine. Provision shall be made for ahead and aster propulsion of the lifeboat. During test of lifeboat engine, PSCO observed that the chief officer was unable to put the engine in neutral. Additionally, when the chief officer attempted to engage both forward and reverse, the propeller did not change direction. 74SOLAS9(14)II-2/4.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2020
Resolution: Lifeboat propulsion system made fully operational. Sureveyor witnessed full operational test.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 December 2020
Resolved
07120 - Each machinery space of category A shall have emergency lighting. The emergency escape trunk from the ECR had 2 lights, one of which was emergency lighting that were both found inoperable. 74SOLAS(14)II-2/13.4.2.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2020
Resolution: Emergency lights were made fully operational.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 December 2020
Resolved
02105 - The condition of the ship and it's equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respect will remain fit to proceed to sea without danger to the ship or persons onboard. PSCO discovered a hydraulic oil leak on the No. 2 steering gear pump with pooled oil in the drip pan and on the deck below. 74SOLAS(14)I/11(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 December 2020
Resolution: Hydraulic oil leak was rectified by the crew and examined to the satisfaction of Surveyor.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 15 December 2020
Resolved
07126- Means shall be produced to control leaks of flammable liquids. The No. 6 Fuel injector on the No. 1 generator failed causing active oil leaks, covering a large portion of the top of the generator with excessive oil accumulation at the case including inside and outside of the drip pans and deck immediately surrounding the generator. Oil soaked lagging was found at the NO. 1 Generator F/O inlet valve. An active L/O leak was found on the "lube oil cooler" of the No. 2 generator causing significant oil accumulation in the drip pan. Although the No. 3 gennerator was not running, an active F/O drip was present in the vicinity of the F/O filters with oil accumulation in the drip pan. Pooled oil was found at the M/E near the base of the No. 3 & 4 cylinders.
74 SOLAS(14) II-2 4.1.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2020
Resolution: Generator leaks were rectified and equipment found operational as well as leak free to the satisfaction of Surveyor. Vessel provided purchase order for new gaskets to serve No. 2 generator lube oil cooler.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 15 December 2020
No resolution recorded
15109 - The company should establish procedures to ensure that the ship is maintained in accordance with the provisions of the relevant rules and regulations established by the company. The checklist for the generators does not include requirements for visual checks of the lube oil cooler, the lube oil cooler was leaking and undetected for an indeterminate amount of time. Due to objective evidence in the above deficiencies, the vessel is not in compliance with relevant conventions. The Captain of the Port questions the adequacy and overall implementation of the vessel's SMS under the ISM Code. An internal audit is required within 90 days to determine whether the ship is operating in compliance with the ISM Code.
74 SOLAS (14) IX/3.1
ISM Code 10.1
50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Fire Fighting › Automatic Sprinkler System › Testing Means for Pump
Issued 16 February 2017
Resolved
Maintenance, testing, and inspections shall be conarried out based on the guidelines developed by the organization. ship cannot provide a record of annual testing and inspection of the watermist system as required by the MSC Circular 1432.
SOLAS (74) II-2/14
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2017
Resolution: Senior Surveyor's report recieved.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 16 February 2017
Resolved
Maintenance, testing and inspections shall be carried out based on teh guide lines developed by teh aorganization. ship cannot provide a record of annual testing and inspection as reguired by MSC Circular 1432.
SOLAS (74a)II-2/14
17ac
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2017
Resolution: Senior Surveyor's report recieved.