MAURY USCG vessel records
← All vessels

PREDATOR

PREDATOR is a 2015 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in May 2026, along with 17 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 13 May 2026.

Built
2015
Last inspected
13 May 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDQ3925
1325162
Flag
UNITED STATES
Maury page id
psix-1325162

Inspections, by type

…with no type recorded3
Years with a record 11 calendar years (2016–2026)
The 18 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)35.9 ft × 13.0 ft × 3.8 ft
Registered tonnagegross 7 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE INC · PORT ANGELES, WA, UNITED STATES · built 2015
Hull materialAluminum
PropulsionDiesel Outdrive
Hull shapeShip
Hull configurationTwin Hull
Hailing portSEWARD, AK
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 29 December 2025 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 18

13 May 2026 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8372821
26 March 2025 Administrative Inspection · Deficiency Check · COI Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 8100305
23 May 2024 Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7933712
28 July 2023 Type not recorded
No type recorded · USCGC LIBERTY (WPB 1334) · USCG Arctic District (CGD-A) · Activity 7764974
11 April 2023 Special · Administrative Inspection · Annual Inspection · Hull Examination · Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7666184
12 August 2022 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 7532045
10 May 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7449638
12 May 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7285186
27 April 2021 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7185221
30 July 2020 Type not recorded
No type recorded · USCGC CHANDELEUR (WPB 1319) · USCG Arctic District (CGD-A) · Activity 7023741
12 May 2020 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6951727
11 October 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6832978
9 May 2019 Administrative Inspection · Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6680965
24 April 2019 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 6669735
18 May 2018 Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6401039
9 May 2017 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6148744
2 May 2017 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6137565
11 May 2016 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5875265

Deficiency record · 17

07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 May 2023 Resolved
The minimum number of portable fire extinguishers must be provided in accordance with the regulations. The operating station must be provided with a 10-B:C portable fire extinguisher.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2023
Resolved 21 June 2023
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 May 2023 Resolved
The location identification and quantity of life jackets stowage must be provided. The child life jackets did not have a location or quantity for identification.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 21 June 2023
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 May 2023 Resolved
As a part of the Employee Assistance Program, there must be one member of the crew who has received the required supervisory training. The list on board did not have any member from the provided crew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 21 June 2023
Resolution: Corrected.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 17 May 2023 Resolved
Each vessel must have a member who is certified as a Radio Operator. No crewman had the required training and FCC Radio Operator permit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 June 2023
Resolved 21 June 2023
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2022 Resolved
Each life jacket carried on a vessel on oceans, coastwise, or great lakes routes, must have a life jacket water light. All water lights expired. Replace all water lights. Vessel restricted to daylight operations only until resolved.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 May 2022
Resolution: New waterlights installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 May 2022 Resolved
Only two fire buckets on board vessel. Provide a third fire bucket.
Action required: 10 - Deficiency Rectified
Resolved 10 May 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2022 Resolved
Life ring grab lines are deteriorated. Repair as original I.A.W. 46 CFR 160.050 (subchapter Q) or replace with new.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 18 May 2022
Resolution: Lifering grab lines satisfactorily repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2022 Resolved
Life ring water light battery expired. Replace water light battery.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 10 May 2022
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 May 2020 Resolved
Meds in first aid kit expired, renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2020
Resolved 27 May 2020
Resolution: First Aid kit was updated.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2020 Resolved
FCC station license expired, renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 June 2020
Resolved 27 May 2020
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2020 Resolved
No proof of enrollment in approved drug testing program. Provide proof.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2020
Resolution: Provided proof of enrollment for drug testing program.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 9 May 2019 Resolved
Port and starboard collision bulkheads had drain holes. Ensure bulkheads are water tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2019
Resolved 15 May 2019
Resolution: Holes were welded
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 May 2019 Resolved
Ensure portable lighting at operating station and engine room are operational.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2019
Resolved 15 May 2019
Resolution: Portable lighting was operational.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 May 2019 Resolved
Ensure first aid kit is up to date.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2019
Resolved 15 May 2019
Resolution: Vessel rep was purchasing updated first aid equipment.
Documentation › Logs/Records › Logbook (official)
Issued 11 May 2016 Resolved
Record fire and MOB drills, and monthly EPIRB test in log book. 46CFR 185.520 and 185.524
Action required: 705 - Other - as specified
Due 11 May 2016
Resolved 11 May 2016
Resolution: Vessel filled out log book on spot.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 May 2016 Resolved
Provide copy of current COD. 46CFR67.7
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 11 May 2016
Resolution: Vessel showed proof of ordering COD.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 11 May 2016 Resolved
Provide emergency instructions to satisfaction of attending marine inspector. 46CFR185.510
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 11 May 2016
Resolution: Provided proper emergency instructions.

Ownership record