← All vessels
CHEM 1250
Tank Barge · Barge class · Built 2010s · USCG Heartland District (CGD-H) · Other hulls named CHEM 1250 · FLOWERS, J. RUSSELL, INC. operator of record, 2023
CHEM 1250 is a 2015 tank barge. The Coast Guard has recorded 12 inspections since 2015, most recently in May 2025, along with 5 deficiencies.
Records from 2015 to 2025. Most recent: inspection, 21 May 2025.
- Built
- 2015
- Last inspected
- 21 May 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
1258267
1325718
Flag
UNITED STATES
—
Maury page id
psix-1325718
Inspections, by type
…with no type recorded1
Years with a record
7 calendar years (2015–2025)
The 12 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Documentation record
Registered dimensions (L × B × D)200.0 ft × 35.0 ft × 12.5 ft
Registered tonnagegross 735 / net 735
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJEFFBOAT LLC · JEFFERSONVILLE, IN, UNITED STATES · built 2015
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 November 2025 · expires 31 December 2026
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it735 - Simplified, Gross Ton
735 - Simplified, Net Ton
735 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 12
21 May 2025
MTSA Verification · Cargo Tank Internal · Internal Structural Exam · COI Inspection · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8136539
15 May 2020
MTSA Verification · Administrative Inspection · Internal Structural Exam · COI Inspection · Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6953727
4 March 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6636596
15 June 2018
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6445243
1 March 2018
Periodic Inspection · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6363820
3 March 2017
Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 6123477
20 May 2016
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5899246
14 March 2016
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5832866
10 August 2015
Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5212186
26 June 2015
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5168938
26 June 2015
Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5172878
9 April 2015
Initial Construction-Excluding Oversight · Initial Certification · Cargo Tank Internal · Internal Structural Exam · Examination of Repairs · MTSA Verification · Administrative Inspection · Hull Examination
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5099566
Deficiency record · 5
Accommodation/Occupational Safety › Ventilation › General
Issued 26 June 2015
Resolved
Repair the bent #1 port void vent pipe.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 June 2015
Resolved
Repair (weld) the fractured bases of the stair hand rail.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 26 June 2015
Resolved
Straighten the bent small stair handrail.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 June 2015
Resolved
Align and re-secure (bolt) the stairway metal grating IVO the bent hand rail.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 26 June 2015
Resolved
Reinstall the vent pipe cable hoist hand crank wire and repair or replace the cable pulley retaining clip.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.