MAURY USCG vessel records
← All vessels

CIRCLE LINE BRONX

CIRCLE LINE BRONX is a 2016 passenger vessel (inspected). The Coast Guard has recorded 17 inspections since 2016, most recently in October 2025, along with 7 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 22 October 2025.

Built
2016
Last inspected
22 October 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 October 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ2555
1326014
Flag
UNITED STATES
Maury page id
psix-1326014

Documentation record

Registered dimensions (L × B × D)165.0 ft × 34.0 ft × 12.0 ft
Registered tonnagegross 99 / net 68
ITC dimensions (L × B × D)154.6 ft × 34.0 ft × 12.1 ft
ITC tonnagegross 692 / net 253
BuilderDUCLOS CORP GLADDING-HEARN SHIPBUILDING · SOMERSET, MA, UNITED STATES · built 2016
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 December 2025 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it692 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
253 - Convention (Subpart B), Net Ton
68 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

17 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

22 October 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8257325
6 November 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8029867
24 October 2024 Annual Inspection · MTSA Verification · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8023672
24 October 2023 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7811781
22 November 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7596299
25 October 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7583298
9 November 2021 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7345510
10 November 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7092727
19 October 2020 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7081012
22 October 2019 MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6839350
21 December 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6601609
16 October 2018 MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6561503
2 October 2018 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6552927
31 July 2018 Excursion Permit
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6496614
15 December 2017 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6322028
7 November 2017 Damage Survey · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6302728
20 December 2016 Plan Review "T" Boat · Deficiency Check · In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6060521

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 October 2024 Resolved
A Class Bulkheads... Must be constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke + flame for 1 hour. MI observed Rolling shutter in A-0 boundy not operating as designed. 46 CFR 116.415(2)(i)
Action required: 705 - Other - as specified
Resolved 6 November 2024
Resolution: See attached Fire Door Servicing report attached. Witnessed satisfactory test of Door.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2024 Resolved
Spaces protected by carbon dioxide and spaces into which carbon dioxide might migrate - " Carbon Dioxide can cause tnjury or death. .." MI observed no CO2 Warning for odorizer(intergreen) In E/r or space outside of engine room. place sinage in both spaces for wintergreen within 14 days. 46 CFR 122.612(i)(2) (i((3) - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 November 2024
Resolution: Witnessed satisfactory placards posted within Engine Room and on engine room door.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 24 October 2024 Resolved
MI Identified no record of VGP annual inspections since 2022. VGP parts 4.1.3 and 4.2 #6 - 16c
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 November 2024
Resolution: Observed completed anual inspection report.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 October 2023 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of its fire equipment. Replace piping for CO2 system within engine room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2023
Resolution: Replaced pipe, witnessed pressure and flow test. All sat.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 November 2021 Resolved
A vessel must comply with the applicable requirements for any radio including the requirements by the FCC. Every vessel must have an inspection by an FCC-licensed technician once every five years. Vessel's Radiotelephony Certificate expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 November 2021
Resolved 15 November 2021
Resolution: Received scanned PDF of valid Vessel's Radiotelephony Certificate.
Engineering › Bilge Water Management System › Not Operational
Issued 23 January 2018 Resolved
Fixed bilge system was not operating properly.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 February 2018
Resolution: Confirmed satisfactory operation of the fixed bilge system.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 23 January 2018 Resolved
Emergency light located in aft portion of engine room was burned out.
Action required: 705 - Other - as specified
Due 23 February 2018
Resolved 12 February 2018
Resolution: Confirmed satisfactory operation of emergency light in engine room.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.