Records from 2016 to 2026. Most recent: inspection, 23 May 2026.
Inspection history · 25
23 May 2026
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8381176
16 January 2026
Vessel Attendance · Internal Structural Exam · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8297244
8 May 2025
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8130941
15 April 2025
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8131177
12 September 2024
Deficiency Check · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 8001348
14 July 2023
Annual Inspection · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7739934
24 May 2023
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7695360
14 March 2023
Hull Examination · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7651738
21 July 2022
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7513171
19 July 2021
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7261704
15 June 2021
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7234291
29 April 2021
Drydock Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7185657
3 March 2021
Administrative Inspection
Administrative · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7149915
9 December 2019
Deficiency Check
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6871570
3 December 2019
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6866575
15 August 2019
Hull Examination
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 6790787
14 March 2019
Administrative Inspection · Examination of Repairs
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6648919
18 December 2018
Drydock Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6600278
6 December 2018
Internal Structural Exam · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6593821
6 November 2018
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6576048
1 November 2018
DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6571384
5 July 2018
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6468553
29 June 2018
Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6464249
15 November 2017
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6306230
16 June 2016
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5909759
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 4 February 2026
Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. Port hull fuel tank void Fire Boy did not alarm at operating station when tested.
46 CFR 176.810
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 April 2026
Resolution: Fireboy audible and visual alarm tested sat.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 February 2026
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. 1st Aid Kit onboard had expired items.
46 CFR 184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2026
Resolved 17 March 2026
Resolution: Expired items were repalaced.
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 4 February 2026
Resolved
Licenses for ship stations in the maritime services will normally be issued for a term of ten years from the date of original issuance, or renewal. Vessel ship station license was expired.
47 CFR 80.25
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 February 2026
Resolved 20 February 2026
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 May 2025
Resolved
(d) A flammable vapor detection system must provide a
visual and audible alarm at the operating station.
MI tested port side vapor detection and found no alarms or lights at operating station. Replace in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2025
Resolved 14 May 2025
Resolution: Installed new vapor detection system. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 8 May 2025
Resolved
(h) An operation and maintenance manual for the flammable vapor detection system must be kept onboard.
Vessel does not have an operation and maintenance manual for the vapor detection system onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2025
Resolved 9 May 2025
Resolution: Received email from vessel rep attesting to correction. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 May 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules.
Both the masthead light and the stern light aboard the vessel are extinguished. As per regulations, these lights are required for proper navigation during nighttime or periods of reduced visibility. Vessel is not permitted to operate during nighttime or periods of reduced visibility until the navigation lights are replaced/repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2025
Resolved 8 May 2025
Resolution: INSTALLED NEW BULBS, ALL SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 12 September 2024
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. Identified transom penetrations were not watertight. Make transom penetrations watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 24 September 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 September 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Found dead end wire within port fuel tank void. Remove wire or install within junction box and have wire supported with metal supports not more than 24 inches apart.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 25 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 September 2024
Resolved
When the flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. Identified fuel fill pipes did not have a conductor between the metallic sections of the fill pipe. Install conductor.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 September 2024
Resolved 24 September 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 July 2023
Resolved
A vapor detection sensor must be located above the expected bilge water level in the following locations:(2) The lowest part of a space containing a fuel tank when separate from the machinery space. Port and starboard fuel tank void vapor detectors are mounted in the overhead.
46 CFR 182.480(e(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2023
Resolved 17 July 2023
Resolution: Vapor detection sensors were relocated to the lowest part of the space.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 14 July 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew.
Starboard aft embarkation gate latch and catch were missing mounting hardware.
46 CFR 177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 July 2023
Resolved 17 July 2023
Resolution: Embarkation latch repaired sat.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 July 2022
Resolved
Electrical connections, wiring, and components for a flammable vapor detection system must comply with part 183 of this chapter. Vapor detection sensors are not properly mounted.
46 CFR 182.480(g)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2022
Resolution: Vapor detection sensors mounted properly.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 July 2022
Resolved
Procedures for checking the proper operation of a flammable vapor detection system must be posted at the primary operating station. Instructions are not posted at primary operating station.
46 CFR 182.480(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2022
Resolution: Vapor detection procedures posted at operating station.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 July 2022
Resolved
An operation and maintenance manual for the flammable vapor detection system must be kept onboard. Operation and maintenance manual was not onboard the vessel.
46 CFR 182.480(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 August 2022
Resolution: Operation and maintenance manual placed onboard the vessel.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 June 2021
Resolved
Prior to carrying passengers in Juneau, conduct the following drills in the attendance of a CG Marine Inspector: Man overboard, Abandon ship, and Fire drill.
Action required: 705 - Other - as specified
Due 30 June 2021
Resolved 19 July 2021
Resolution: Witnessed satisfactory completion of man overboard drill. Discussion of abandon ship and fire procedures.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 June 2021
Resolved
First aid kit had expired medications. Provide new first aid kit or replacement medications.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2021
Resolved 23 June 2021
Resolution: First aid kit was found satisfactory.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 June 2021
Resolved
Vessel does not have the required two portable operational lights. Provide two operational portable lights.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2021
Resolved 23 June 2021
Resolution: Verified two operational portable lights.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 June 2021
Resolved
The vapor detection system is not operational. Prove proper operation of vapor detection system.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2021
Resolved 23 June 2021
Resolution: Verified satisfactory operation of vapor detection systems.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 June 2021
Resolved
The batteries were not strapped down. Properly secure all batteries.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2021
Resolved 23 June 2021
Resolution: Verified batteries were properly strapped down.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 June 2021
Resolved
One of the required fire extinguishers has not been serviced as required. Service fire extinguisher and provide proof of service.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 June 2021
Resolved 23 June 2021
Resolution: Verified satisfactory servicing of portable extinguisher.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2021
Resolved
Prove proper operation of machinery via sea trials.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2021
Resolved 23 June 2021
Resolution: Verified satisfactory operation of machinery while underway.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 December 2019
Resolved
Forward heating fuel tank fill flex piping missing bonding wire between tank and fill fitting. Install bonding strap.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2019
Resolution: Bonding wire installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2019
Resolved
Battery storage box missing ventilation. Install vents.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 December 2019
Resolution: Vent installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 December 2018
Resolved
Crop and Renew pitted area on hull and outboard side shell plating in the port swim step.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2019
Resolution: Area crop and renewed to good metal.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 6 December 2018
Resolved
Crop and Renew pitted area on hull in the Starboard swim step.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2019
Resolution: Area crop and renewed to good metal.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 November 2018
Resolved
Provide Alcohol testing equipment onboard for each crew member onboard
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2018
Resolution: Vessel has provided new alcohol testing equipment
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 1 November 2018
Resolved
Conduct underway abandon ship, man overboard, and fire drill with Coast Guard Inspectors prior to carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2021
Resolved 24 June 2021
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 1 November 2018
Resolved
Make all wire runs from stern going fwd thought all void bulkheads smoke and vapor tight and the thought deck form Starboard #2 void to main cabin
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 November 2018
Resolution: Vessel has made all wire runs from stern going fwd thought all void bulkheads smoke and vapor tight and the thought deck form Starboard #2 void to main cabin
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2018
Resolved
Make #1 port void available for inspection
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2018
Resolution: Completed ISE on void all sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 November 2018
Resolved
Make both aft swim step voids water tight
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 December 2018
Resolution: Both swim steps are now water tight
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 1 November 2018
Resolved
Crop and renew pitted area along both side of the keel running from the first frame fwd to the last frame aft to remove around 13 pits in the port #2 void. Also move tank to check pits under tank.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2019
Resolution: Area crop and renewed to good metal.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2018
Resolved
Make port side transducer in #2 void watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 August 2019
Resolution: Area of plate surrounding transducer crop and renewed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 June 2018
Resolved
Complete all dry dock work list items before carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2018
Resolution: Drydock items completed.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 June 2018
Resolved
Make IBA so it is in a float free arrangement.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2018
Resolution: Vessel has moved the IBA to the aft swim step.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 June 2018
Resolved
Install a 40-BC in the vicinity of the outboard and battery box on the aft deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 July 2018
Resolution: Vessel has installed 40-BC on aft deck bulkhead
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 15 November 2017
Resolved
Vessel must prove servicing of both pre-engineered fixed gas fire extinguishing systems - 46 CFR 176.810 - Prior to movement (One-time voyage to drydock <1nm away authorized).
Action required: 60 - Rectify deficiencies prior to movement
Due 15 November 2017
Resolved 29 June 2018
Resolution: Vessel has serviced both pre-engineering fire systems.
Lifesaving › Lifebuoys › Serviceable
Issued 15 November 2017
Resolved
Replace unservicable lifebuoy on aft superstructure - 46 CFR 180.70(a)(2) - Prior to carrying pax.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 20 March 2018
Resolution: Completed, sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 November 2017
Resolved
Replace floating water light on lifebuoy with one CG approved under 46 CFR 161.010 - 46 CFR 180.70(d)(2) - Prior to nighttime operations
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 20 March 2018
Resolution: Completed, sat.
Fire Fighting › Fire Bucket › Availability
Issued 15 November 2017
Resolved
Add fire buckets to vessel - 46 CFR 181.610 - Prior to movement (Vessel authorized one-time transit to drydock <1nm away).
Action required: 60 - Rectify deficiencies prior to movement
Due 15 November 2017
Resolved 20 March 2018
Resolution: Found three fire buckets (metal galvanized), sat
Operations/Management › Drills/Instruction › Not Conducted
Issued 15 November 2017
Resolved
Perform fire and man overboard drills to the satisfaction of the attending CG Marine Inspector - 46 CFR 185.520/.524 - prior to carrying pax.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 29 June 2018
Resolution: Got vessel underway to conduct man overboard and fire drills both drills were sat.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 15 November 2017
Resolved
Prove enrollment of vessel crew in drug and alcohol testing program and access to Employee Assistance Program - 46 CFR 16 - Prior to carrying pax.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2017
Resolution: Documents provided from shoreside office to be kept on vessel.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 15 November 2017
Resolved
Provide alcohol testing strips stored IAW manufacturer's requirements - 46 CFR 4.06-3 - Prior to operating on voyages >2 hrs in length.
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 29 June 2018
Resolution: Vessel has replaced alcohol testing strips
Engineering › Gasoline Engine (propulsion) › Engine Block (4 cycle)
Issued 15 November 2017
Resolved
Prove proper operation of starboard main engine - 46 CFR 182.200 - Prior to carrying pax
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 29 June 2018
Resolution: Vessel had replaced both engine from Yamaha 350 to Mercury 300 since they could find another Yamaha 350 to replace the starboard engine.