Records from 2016 to 2026. Most recent: inspection, 13 April 2026.
Inspection history · 12
13 April 2026
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8345827
18 March 2025
COI Inspection · Hull Examination
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8095677
24 April 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7904946
25 April 2023
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7710906
20 April 2022
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7445324
13 April 2021
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7173542
7 January 2020
Hull Examination · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6926184
23 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6660828
10 April 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6386898
27 April 2017
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6134009
3 November 2016
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6034533
18 April 2016
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5850219
Engineering › Bilge Water Management System › Not Operational
Issued 10 April 2018
Resolved
Prove proper operation of aft bilge pump in automatic mode; the bilge float switch is currently inoperable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2018
Resolved 8 May 2018
Resolution: Vessel owner replaced the faulty float switch, and proved proper operation of the bilge pump while in automatic mode.
Communications › Alarms/Indicators › High Water Alarm
Issued 2 May 2017
Resolved
Mount high-level float switch in the bilge, and prove proper operation of the associated alarm.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 19 May 2017
Resolution: Vessel's float switch was mounted in the aft bilge, and the high-level alarm tested satisfactorily by the owner.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 May 2017
Resolved
Replaced the expired consumables/medication in the first aid kit.
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 19 May 2017
Resolution: All expired consumables/medication were replaced in the first aid kit.