STI GRAMERCY is a tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in May 2025, along with 2 deficiencies and 5 operational controls.
Records from 2016 to 2025. Most recent: inspection, 10 May 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it29806 - Convention (Subpart B), Gross Ton 13834 - Convention (Subpart B), Net Ton 29735 - Simplified, Gross Ton 49990 - Dead Weight, Metric Ton 13834 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 13
10 May 2025COC-CHEM & TVE Renew · PSC B · Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 8129978
6 October 2023PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7804498
27 November 2021PSC B · COC-CHEM Renew
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7357826
27 November 2021Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7357903
23 November 2021Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 7356591
4 April 2020PSC B · COC-CHEM & TVE Renew
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6931622
1 April 2020Type not recorded
No type recorded · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 6933949
26 November 2018ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6584445
18 August 2018Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 6511126
11 October 2016Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6020004
10 October 2016Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6019572
8 October 2016Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6018787
12 April 2016ISPS II Exam · Ballast Water Examination · COC-CHEM & TVE Annual
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5852259
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 10 May 2025Resolved
Every Company should develop, implement and maintain a safety management system. PSCO observed that the Inert Gas Generator Log has not been filled out daily by PIC, as required by policy.
ISM A 1.4
16AC
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2025
Resolved 28 May 2025
Resolution: Vessel has submitted both a class report, as well as proof of PIC conducting daily tank sounding to confirm O2 content to be below threshold.
04 - Emergency Systems › N/A - No Subsystem › Emergency towing arrangements and procedures
Issued 10 May 2025Resolved
The design and construction of the towing arrangements shall be in accordance with IMO resolution MSC.33(63). The Stern emergency towing has an inoperable towing light.
33 CFR 155.235
10C
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 May 2025
Resolved 10 May 2025
Resolution: Vessel was able to replace the light on the the stern emergency towing system.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.