Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
9156 - Convention (Subpart B), Gross Ton
9156 - Regulatory (Subpart C or D), Gross Ton
2746 - Convention (Subpart B), Net Ton
2746 - Regulatory (Subpart C or D), Net Ton
10210 - Dead Weight, Ton
18564 - Displacement, Ton
Maury page id
psix-1326575
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 3
28 January 2025PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8070776
24 October 2022PSC B
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7578975
24 June 2015ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5162537
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 28 January 2025Resolved
For this purpose, the following functional requirements shall be met; additional aids for escape shall be provided as necessary to ensure accessibility, clear marking, and adequate design for emergency situations. PSCO observed several exit route arrow signs throughout engine room that were no longer photo luminescent and would not aid crew members escape in an emergency situation.- 74SOLAS04 II-2/13.1.3, Code 40ac
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 March 2025
Resolution: crew replaced worn out photoluminescent exit stickers in E/R
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 24 October 2022Resolved
The general alarm system shall be supplemented by either a public address system complying with the requirements of paragraph 7.2.2 of the Code or other suitable means of communication. The public address system shall be a loudspeaker installation enabling the broadcast of messagesinto all spaces where crew members or passengers, or both, are normally present, and to muster stations. The public address system cannot be heard in the ROV portable accomodation module, or te client's portable accomodation module.
74SOLAS(20)III/6.4.2, LSA 7.2.2
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2022
Resolved 28 October 2022
Resolution: Loudspeakers were verified to be installed in the ROV Portable Accommodation Module and the Clients Portable Accommodation Module and tested in the presence of the attending surveyor and found to be in working as intended.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 24 October 2022Resolved
In all ships general arrangements plans (fire control plans) shall... show clearly the various fire sections, fire detection, fire alarm systems, fire extinguishing appliances. The ROV portable accommodation module's fire detection, fire extinguisher, and fire alarm is not listed on the vessel's fire control plan
74SOLAS(01)II-2/20.1
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 November 2022
Resolved 28 October 2022
Resolution: The Fire Control Plan was amended at this time to reflect the the requirements of 74 SOLAS (01) II-2/20.1. A total of Eighteen (18) ABS Approved Fire Control Plans were updated at this time.