BW BREEZE is a 2014 tank ship. The Coast Guard has recorded 16 inspections since 2016, most recently in June 2026, along with 10 deficiencies and 1 operational control.
Records from 2016 to 2026. Most recent: inspection, 1 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it53852 - Dead Weight, Metric Ton 46789 - Convention (Subpart B), Gross Ton 73415 - Displacement, Metric Ton 46789 - Regulatory (Subpart C or D), Gross Ton 18825 - Convention (Subpart B), Net Ton 18825 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 16
1 June 2026Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8385838
18 December 2025PSC B · COC-GAS Annual
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8282187
18 January 2025COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8060742
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 18 December 2025Resolved
The changing of set pressure and corresponding alarms IAW REG 13.4.1 under provision of 8.2.6 should be carried out under supervision of the master in accordance with procedures approved by administration.
PSCO observed changeover procedures in use not approved by administration. PSCO observed no procedure for changing alarms.
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 December 2025
Resolved 30 December 2025
Resolution: Recieved report from class attesting to approval of changeover procedures
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 18 January 2025Resolved
Gas detection equipment should be so designed that it may readily be tested. PSCO observed gas detection system unable to be tested due to internal system failure.
17/10C
74 SOLAS 20 VII/13.1
1993 IGC 13.6.6
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 18 January 2025
Resolved 18 January 2025
Resolution: Vessel identified severed line and a failed 3-way valve preventing uptake from all detection lines as the cause of the failure and replaced with parts onboard.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 18 January 2025Resolved
Where electrical equipment is installed in gas-dangerous spaces or zones as provided in 10.1.4, it should be to the satisfaction of the administration.
PSCO observed cracked cable gland on tank top #4.
74 SOLAS (20) VII / 13.1
1993 IGC 10.1.5
16ac
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2025
Resolved 12 March 2025
Resolution: Vessel provided report attesting to the rectification of the deficiency.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Atmosphere testing instruments
Issued 16 August 2021Resolved
Gas detection equipment should be so designed that it may be readily tested. Upon testing of the gas detection system for the hold spaces, PSCO was unable to verify calibration by means of using 50% L.E.L. span gas. L.E.L. sensor was reading 13-35% over the required 50%. 74 SOLAS (09) CONS. Chap VII/13.7 17b
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 August 2021
Resolved 17 August 2021
Resolution: Vessel provided report from flag state [name withheld] attesting to the calibration and crew training from 3rd party surveyor.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 28 May 2020Resolved
Before the ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use.
Vessel unable to start the free-fall lifeboat. Crew attempted to repair for 1.5 hours but still unable to start. Weekly testing and maintennce records up to date. Crew stated to have satisfactory tested lifeboat engine the morning of PSC exam.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 May 2020
Resolution: Vessel's crew repaired the lifeboat battery charging system and vessel's class society attested to repairs/testing of lifeboat engine.
Oil filtering equipment referred to in Paragraph 2 of this regulation, in considering the design of such equipment and approvals, the administration shall have regard to the specification recommended by the organization. The screen of the oil content meter is dark. History of operational use is therefore not accessible for verification.
Condition: Invalid
Action required: 15 - Rectify deficiencies by next port
Due 23 December 2018
Resolved 23 December 2018
Resolution: Oil content meter OMD-24 unit replaced withnew "like for like" type approved unit. New unit and 3 way valve tested and found satisfactory. Operational history still available on board by using old memory card in new unit.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 16 December 2017Resolved
Vessel is past is compliance date in 33 CFR 151.2035 and has an inoperable BWTS. See MISLE activity # 6320458 for full text of deficiency. (33 CFR 151.2035 (a)) (40c)
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 December 2017
Resolved 8 March 2018
Resolution: Vessel submitted documentation stating their BWTS is fully functioning.
Operations/Management › Ballast Water Managment › Training
Issued 16 December 2017Resolved
Vessel's ballast water management plan makes no mention of U.S. ballast water handling requirements from 33 CFR 151.2050 (g). See MISLE activity # 6320458 for full text of deficiency. (33 CFR 151.2050(g)) (40c)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 December 2017
Resolved 9 February 2018
Resolution: Received USA specific appendix to BWMP that addresses requirements of 33 CFR 151.2050 (g).
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 16 December 2017Resolved
Cargo tank pressure relierf valve vent exits should be arranged at a distance of at least B or 25m, whichever is less, from the nearest air intake or opening to accomodation spaces or other gas safe spaces. The vent mast for cargo tank #4, aft of the electric motor room, does not meet 25m distance reqts. Flag equivalence determined insufficient evidence of compliance w/ 46CFR154.32. (74 SOLAS 14 VII/13.1 REF IGC 93/8.2.10 and 46CFR154.32) (16Jun18)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 June 2018
Resolved 11 June 2018
Resolution: Vessel subject to special restrictions listed in SOE issued 11JUN2018, Serial #C1-1802068.
Documentation › Safety Management System › Key Shipboard Operations Plans/Instructions
Issued 16 December 2017Resolved
In the case of cargo tanks permitted to have >1 relief valve setting, the changing of the set pressures under 8.2.6 and the corresponding resetting of alarms referred to in 13.4.1, should be carrioued out in accordance with procedures approved by the Administration. Vessel is authorized "at sea" 0.25 bar & "in harbor" 0.45 bar MARVS, but procedure for changing MARVS is not approved by flag/RO and makes no mention of changing high pressure alarm set-points (0.22 bar at sea, 0.40 bar in harbor). (74 SOLAS 14 VII/13.1 REF IGC 93/8.2.7) (50ac)
Action required: 705 - Other - as specified
Due 16 January 2018
Resolved 9 February 2018
Resolution: Received updated MARV changing procedure, approved by LR, that meets requirements of IGC 8.2.7.