Records from 2016 to 2025. Most recent: inspection, 10 August 2025.
Documentation record
Registered dimensions (L × B × D)174.4 ft × 31.9 ft × 14.0 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)174.4 ft × 31.9 ft × 14.0 ft
ITC tonnagegross 496 / net 148
BuilderBREAUX BROTHERS ENT · LOREAUVILLE, LA, UNITED STATES · built 2017
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portGALLIANO, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it496 - Convention (Subpart B), Gross Ton
95 - Regulatory (Subpart C or D), Gross Ton
148 - Convention (Subpart B), Net Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
10 August 2025
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8206754
4 August 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8193932
13 November 2024
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8031806
1 August 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7971785
5 February 2024
Appeal
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7860980
17 May 2023
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7679766
14 November 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7593947
11 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7110487
20 May 2019
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6688377
2 April 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6654124
16 March 2018
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6373247
18 April 2017
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6127056
27 March 2017
COI Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6112442
13 March 2017
Administrative Inspection · Deadweight Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6104073
14 February 2017
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6092008
17 June 2016
Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6020783
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 August 2025
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Two Gallons of oil was released into Bayou Lafourch while the Fast Lion was moored in Port Fourchon due to s suspected turbo failure on the port generator.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2025
Resolution: See technician report attached in documents tab.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 August 2025
Resolved
Updated charts required for intended voyage. Paper charts last updated 2023and C-map chart card last updated 2014. Provide proposal to have updated charts.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2025
Resolved 4 August 2025
Resolution: Updated chart onboard. Still need to propose a plan for future updates.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 4 August 2025
Resolved
Vessel required to have bilge alarms. Forward peak bilge alarm active.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2025
Resolved 4 August 2025
Resolution: Space pumped out. Operation of alarm sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 August 2025
Resolved
Vessel required to have bilge suction for each watertight compartment. Bilge suction for forward peak clogged and unable to be pumped.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2025
Resolved 4 August 2025
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 August 2024
Resolved
An ammeter used for measuring current of a generator must be provided. An ammeter was not present on the switchboard leaving an opening.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2024
Resolution: Amp meter repalced.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 August 2024
Resolved
Nonconducting mats must be provided on the deck in front of each switchboard. The nonconductive mat in front of the switchboard was ripped up and not in good condition.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2024
Resolution: Mat replaced
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 August 2024
Resolved
A temporary electric cord must be constructed and used in compliance with the requirements of subchapter J. Two (02) extension cords were found to be permanently used in supplying blowers to cool HPU pumps.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 August 2024
Resolution: Cords removed. Representive contacted engineering, verified the extra blowers not needed for safe operation of systems
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 August 2024
Resolved
The construction and arrangement of a vessel must allow for the safe operation of a vessel. Bracket holding the exhaust piping over the No.4 MDE had a cracked weld.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 September 2024
Resolved 2 August 2024
Resolution: Bracket welded.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 May 2023
Resolved
Vessel must have an interconnected fire detection system in compliance with 46 CFR 181.450 in all enclosed areas where passengers & crew have routine access; vessel did not have appropriate fire detection in all areas.
46 CFR 181.405(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 June 2023
Resolved 21 August 2025
Resolution: Detectors, Audible and Visual alarms installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 17 May 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 17 May 2023
Resolution: Electronic copies obtained with battery backup power.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 5 April 2017
Resolved
Did not conduct Man Overboard, Abandon Ship or Fire Drills. Must be conducted satisfactorily in the presence of a CG Marine Inspector prior to carrying passengers per the issued CG-835.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 18 April 2017
Resolution: Witnessed satisfactory run of drills including MOB, abandon ship, and fire.
Engineering › Engine Controls (Electric/Electronic) › Software
Issued 5 April 2017
Resolved
Need MSC approval of satisfactory completion of DP and Sea Trials prior to carrying passengers per the issued CG-835.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 April 2017
Resolved 16 March 2018
Resolution: Cleared, USCG Marine Inspector recieved approval letter from 03JUL17 providing approval from MSC. Added to documents.