Records from 1992 to 2026. Most recent: inspection, 22 April 2026.
Documentation record
Registered dimensions (L × B × D)75.9 ft × 34.0 ft × 10.0 ft
Registered tonnagegross 278 / net 189
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderST CHARLES STEEL WORKS INC · ST CHARLES, LA, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 January 2026 · expires 31 January 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it189 - Regulatory (Subpart C or D), Net Ton
278 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 37
22 April 2026
Vessel Attendance · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8347221
14 May 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8135463
20 May 2024
Administrative Inspection · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7908595
29 November 2023
In-Service Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7831394
15 February 2023
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7608074
13 August 2022
Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7532456
13 August 2022
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7870533
31 January 2022
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7388281
16 February 2021
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7143139
18 March 2020
Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6928447
17 March 2020
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6933642
4 December 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6867297
19 December 2018
Administrative Inspection · Deficiency Check · Initial Certification
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6600127
18 July 2013
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4658201
5 December 2012
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4498119
4 November 2012
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4478530
9 August 2012
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4406721
10 July 2012
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4374483
30 May 2012
Industry Initiated Exam · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4313746
11 October 2011
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 4165524
8 May 2008
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3213015
9 March 2008
Type not recorded
No type recorded · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3161687
9 March 2008
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3161708
5 July 2002
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1655001
5 September 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 48752
5 September 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 108742
16 May 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 659174
20 April 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 10954
20 April 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 277909
8 April 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 19768
8 April 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 277865
11 April 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 195960
11 April 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 753604
31 March 1997
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 40570
13 October 1993
Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 122790
4 December 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 92023
4 December 1992
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 226498
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 August 2022
Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford protection against hazards to life, property, and the environment. Vessel involved in a grounding that resulted in a hole in the #3 PORT fuel oil tank. Vessel is authorized to transit to St. Louis area to attend a shipyard for repairs. Vessel's crew must monitor the water / fuel level in the tank every 30 minutes while transiting and if condition changes contact Sector UMR command center. Once at a shipyard crew needs to contact Sector UMR inspection office for repair oversight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 September 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 February 2022
Resolved
Make permanent repairs to inset and associated internal structure in bow rake, starboard of the keel prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 19 September 2022
Resolution: Cleared to the satisfaction of the attending Coast Guard marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 February 2022
Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Battery boxes were found unsecured.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2022
Resolved 22 February 2022
Resolution: Received emailed pictures satisfactory to clear def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 February 2022
Resolved
Machinery must be designed and maintained to provide for safe operation. A hydraulic hose for the port side flanking rudder ram is abraded.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2022
Resolved 22 February 2022
Resolution: Received photos via email sufficient to clear def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 March 2020
Resolved
Machinery and electrical systems must be designed and maintained to provide for safe operation of the towing vessel. Propulsion machinery, including main engines, reduction gears, shafting, bearings, propellers and rudders must be maintain to ensure proper operation. Vessel was involved in a marine casualty grounding on a dike resulting in STBD engine keel cooler damage. Dry-Dock vessel, make proper repairs to STBD side keel cooler and prove proper operation of STBD side propulsion equipment to the satisfaction of the Coast Guard marine inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 June 2020
Resolution: Keel cooler replacement in kind complete and operating properly. (Attested by company rep).
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 March 2019
Resolved
Label on semi-portable fire extinguisher is illegible. Replace extinguisher with 160-B, semi-portable extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2019
Resolved 9 April 2019
Resolution: Received photographic evidence that vessel purchased a semi-portable extinguisher rated 30-A: 240-B:C which exceeds the requirement.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 5 March 2019
Resolved
Main deck passageway does not meet emergency lighting requirements. Install lighting or alternative as allowed in stated site.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 April 2019
Resolved 7 March 2019
Resolution: Received photographic evidence that e-light was added to main deck passageway.
Navigation
Issued 20 April 2000
Resolved
INLAND NAV RULES MISSING
Condition: Unknown
Due 20 May 2000
Resolved 25 October 2002
Resolution: Cleared for administrative reasons.
Lifesaving
Issued 20 April 2000
Resolved
NOT ENOUGH PFD'S FOR AMOUNT OF PERSONNEL ONBOARD.
Condition: Unknown
Due 20 May 2000
Resolved 25 October 2002
Resolution: Cleared for administrative reasons.
Documentation
Issued 20 April 2000
Resolved
OIL TRANSFER PROCEDURES WERE MISSING.
Condition: Unknown
Due 20 May 2000
Resolved 25 October 2002
Resolution: Cleared for administrative reasons.
Navigation
Issued 20 April 2000
Resolved
LOCAL NOTICE TO MARINERS WAS NOT ONBOARD.
Condition: Unknown
Due 20 May 2000
Resolved 25 October 2002
Resolution: Cleared for administrative reasons.
Documentation
Issued 8 April 2000
Resolved
NO OIL TRANSFER PROCEDURES ON BOARD
Condition: Unknown
Due 30 May 2000
Resolved 25 October 2002
Resolution: Cleared for administrative reasons.
Documentation
Issued 8 April 2000
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 May 2000
Resolved 16 May 2000
Documentation
Issued 8 April 2000
Resolved
ORIGINAL CIRTIFICATE EXPIRED.
Condition: Unknown
Due 6 June 2000
Resolved 16 May 2000
Lifesaving
Issued 8 April 2000
Resolved
PFD'S ON VSL WHERE IN POOR CONDITION. REPLACEMENT RECOMENDED.
Condition: Unknown
Due 30 May 2000
Resolved 25 October 2002
Resolution: Cleared for administrative reasons.