TORM DORIS is a 2015 tank ship. The Coast Guard has recorded 13 inspections since 2016, most recently in October 2025, along with 1 deficiency and 1 operational control.
Records from 2016 to 2025. Most recent: inspection, 7 October 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it49680 - Dead Weight, Metric Ton 60305 - Displacement, Metric Ton 29553 - Convention (Subpart B), Gross Ton 29553 - Regulatory (Subpart C or D), Gross Ton 13632 - Convention (Subpart B), Net Ton 13632 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 13
7 October 2025COC-CHEM & TVE Renew
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 8247089
2 October 2025Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8245474
1 September 2024COC-CHEM & TVE Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7991968
28 July 2023PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7754695
6 December 2021PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7363209
30 November 2020PSC B · COC-CHEM & TVE Renew
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7103410
16 November 2020Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7096469
5 January 2019Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6605961
27 August 2018Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6524199
25 August 2018COC-CHEM & TVE Renew · Ballast Water Examination · ISPS II Exam
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 7 October 2025Resolved
74SOLAS(20) II-2/4.5.3.1: The venting systems of cargo tanks shall be entirely distinct from the air pipes of the other compartments of the ship. The arrangements and position of openings in the cargo tank deck from which emissions of flammable vapors can occur shall be such as to minimize the possibility of flammable vapors being admitted to enclosed spaces containing a source of ignition or collecting in the vicinity of deck machinery and equipment which may constitute an ignition hazard. PSCO observed cargo vapors venting to atmosphere due to small leak in vapor inlet flange on pressure vacuum breaker #2.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 October 2025
Resolved 7 October 2025
Resolution: Action taken: Prior to cargo. PSCO cleared deficiency onboard 7OCT25 after crew tightened vapor inlet flange on pressure vacuum breaker #2. Soap test ALL SAT.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National