Records from 2017 to 2025. Most recent: inspection, 17 July 2025.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 24.0 ft × 6.0 ft
Registered tonnagegross 8 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSTEPHEN J MILLER · BLAINE, WA, UNITED STATES · built 2006
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeSail (Distinct Keel)
Hull configurationTwin Hull
Hailing portKAWAIHAE, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 28 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
8 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
17 July 2025
Annual Inspection · Deficiency Check
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8189072
19 December 2024
Examination of Repairs · Damage Survey
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8049490
7 August 2024
Examination of Repairs · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7961811
23 July 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7947658
27 April 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7676867
18 October 2022
Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7579769
5 May 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7444799
15 December 2021
In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7369316
21 October 2021
Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7345636
27 April 2021
COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7180872
21 October 2020
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7082647
24 June 2020
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6984828
3 December 2019
Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6865851
14 August 2019
Administrative Inspection · Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6783454
26 July 2019
Drydock Extension · Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6762384
6 August 2018
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6502980
23 October 2017
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6344565
11 May 2017
Hull Examination · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6140009
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 17 July 2025
Resolved
Portable extinguishers must be inspected and maintained in accordance with NFPA 10. Vessel operators must provide proof of proper annual maintenance for portable fire extinguishers to USCG.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2025
Resolved 25 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 May 2022
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers provided that the pump is listed by an independent laboratory as meeting the requirements in UL 1113. Bilge pumps are not UL 1113 approved.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 18 May 2022
Resolution: UL rated bilge pumps installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 May 2022
Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories. Fuse block is blade type.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2022
Resolved 18 May 2022
Resolution: Cartridge type fuse block installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 December 2019
Resolved
The vessel shall not have any conditions that materially and/or adversely affect the vessel’s seaworthiness or fitness for service or route. Repair port side 4ft hull fracture located mid to aft ship. Repair starboard 1ft hull fracture located mid to aft ship.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2019
Resolution: Hull repairs where completed and sea trials where performed, all sat.