Records from 2015 to 2025. Most recent: inspection, 21 November 2025.
Inspection history · 21
21 November 2025
COC-GAS Renew · PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 8268921
16 December 2024
Administrative Inspection · COC-GAS Annual · PSC B
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 8047596
1 December 2023
PSC B · COC-GAS Renew
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7830164
9 January 2023
COC-GAS Annual
Type not classified · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7615273
3 January 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7615896
1 January 2023
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7615087
8 July 2022
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7500883
19 November 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7354234
11 November 2021
PSC B · COC-GAS Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7346405
10 November 2021
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7349077
26 October 2020
In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7084134
29 September 2020
COC-GAS Annual
Type not classified · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7065241
27 September 2020
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7058749
14 August 2019
ISPS II Exam · COC-GAS Renew · Ballast Water Examination
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6783119
9 August 2018
COC-GAS Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6497784
24 July 2017
COC-GAS Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 6213869
20 March 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6117890
10 March 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6102769
25 January 2017
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6076984
26 May 2016
Ballast Water Examination · COC-GAS Annual · ISPS II Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5882535
17 October 2015
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5746454
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 16 December 2024
Resolved
Pressure relief valves should be set and sealed by a competent authority acceptable to the administration. Both seals on the pressure relief valves on the vessels deck tank have rusted through and no longer seal the pressure relief valve setting.
93 IGC 8.2.5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 19 December 2024
Resolved 3 March 2025
Resolution: Pressure relief valve settings retested and resealed.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 16 December 2024
Resolved
Suitably marked decontamination showers and an eyewash station should be available on deck. The vessels eyewash station did not have adequate water pressure.
93 IGC 14.4.3
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 January 2025
Resolved 3 March 2025
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 January 2023
Resolved
The master shall ensure that a vessel transferring cargo, while fast to a dock or while at anchor in port displays a warning sign at the gangway facing the shore, so that it may be sen from the shore, facing outward towards the water, and each letter be 3 in. high. The vessel did not have sign facing outward and the inboard sign did not have letters 3 in/ high.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2023
Resolved 24 January 2023
99 - Other › N/A - No Subsystem › Other (MARPOL operational)
Issued 9 January 2023
Resolved
For any vessel that is equipped with ballast water tanks and bound for ports or places in the US must submit a ballast water report no later than 6 hours after arrival at the port or place or destinationl Vessel did not submit an nbic report.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 9 January 2023
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 11 November 2021
Resolved
ON SHIPS CARRYING FLAMMABLE OR TOXIC PRODUCTS OR BOTH, A WATER-SPRAY SYSTEM FOR COLLING, FIRE PREVENTION, AND CHEM PROTECTION SHOULD BE INSTALLED TO COVER THE LOADING MANIFOLD. NONE OF THE SIX DECK SPRAY NOZZLES PROTECTING THE STARBOARD MANIFOLD WERE OPERABLE. CORRECT PRIOR TO CARGO OPERATION OF STARBOARD MANIFOLD. - IGC(93)/11.3.1.3
Action required: 705 - Other - as specified
Due 30 November 2021
Resolved 14 November 2021
Resolution: Vessel submitted Class Report attesting to the correction of this deficiency.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 11 November 2021
Resolved
TO ASSIST IN CASUALTY INVVESTIGATIONS, SHIPS WHEN ENGAGED ON INTERNATIONAL VOYAGES SUBJECT TO THE PROVISIONS OF REGULATION 1.4, SHALL BE FITTED WITH A VOYAGE DATA RECORDER. PSCO OBSERVED THE ANNUAL PERFORMANCE TEST HAS NOT BEEN COMPLETED ON THE VDR. 74SOLAS(2020) V/20.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 November 2021
Resolution: PSC NOLA received a class report from BV satisfying the requirement.
01 - Certificates & Documentation › 013 - Documents › Survey report file
Issued 11 November 2021
Resolved
EVERY LIFERAFT, INFLATABLE LIFEJACKET, AND MES SHALL BE SERVICED AT INTERVALS NOT EXCEEDING 12 MONTHS. PSCO OBSERVED THAT THE VESSEL'S INFLATABLE LIFERAFTS HAVE NO RECEIVED THEIR ANNUAL SERVICING. - 74SOLAS (2020) III/20.8.1
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 November 2021
Resolution: PSC NOLA received a class report from BV satisfying the requirement.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 11 November 2021
Resolved
THE RING, LINES, AND LETTERS SHALL BE PAINTED IN WHITE OR YELLOW ON A DARK GROUND OR IN BLACK ON A LIGHT GROUND. PSCO OBSERVED THE LOADLINE MARKINGS ON BOTH STARBOARD AND PORT SIDES HAD NOT BEEN PROPERLY PAINTED. - ICCL /8
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 19 November 2021
Resolution: PSC NOLA received a class report from BV satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 October 2020
Resolved
The condition of the ship and its equipment shall be maintained to conform with present regulations to ensure the ship remains fit to proceed to sea without danger to the ship or persons on board. During its outbound transit, a report was made that a loud banging noise was coming from the MDE's #4 cylinder. Vessel is to remain at Breakwater Anchorage until causal analysis and repair are completed to the satisfaction of class.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 26 October 2020
Resolved 26 October 2020
Resolution: See attached class survey report.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 18 August 2019
Resolved
THE LIFERAFT PAINTER SYSTEM SHALL PROVIDE A CONNECTION BETWEEN THE SHIP AND THE LIFERAFT AND SHALL BE SO ARRANGED AS TO ENSURE THAT THE LIFERAFT WHEN RELEASED AND, IN THE CASE OF AN INFLATABLE LIFERAFT INFLATED, IS NOT DRAGGED UNDER BY THE SINKING SHIP. PSC OBSERVED STBD SIDE LIFERAFT PAINTER ATTACHED TO THE VESSEL BYPASSING WEAK LINK ALLOWING THE LIFERAFT TO BE DRAGGED UNDER.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 18 August 2019
Resolved 18 August 2019
Resolution: DEFICIENCY RECTIFIED