R/V JIM FRANKS

R/V JIM FRANKS is a 2016 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 2016, most recently in December 2025, along with 31 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 8 December 2025.

Built
2016
Last inspected
8 December 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 December 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI5355
1327880
Flag
UNITED STATES
Maury page id
psix-1327880

Documentation record

Registered dimensions (L × B × D)57.0 ft × 24.0 ft × 9.4 ft
Registered tonnagegross 84 / net 68
ITC dimensions (L × B × D)57.0 ft × 24.0 ft × 9.4 ft
ITC tonnageNot recorded
BuilderGEO SHIPYARD INC · NEW IBERIA, LA, UNITED STATES · built 2016
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portOCEAN SPRINGS, MS
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Regulatory (Subpart C or D), Net Ton
84 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 25

8 December 2025 Administrative Inspection · Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8279529
8 December 2025 Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8279537
4 February 2025 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8074664
19 March 2024 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7882299
18 January 2024 Internal Structural Exam · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7848830
1 November 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7824860
7 February 2023 Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7633493
15 January 2023 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7619294
10 January 2023 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7620303
22 July 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7513635
11 March 2022 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7411290
2 February 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7389587
9 December 2021 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7369047
20 July 2021 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7264191
20 January 2021 Administrative Inspection · Examination of Repairs · Internal Structural Exam · DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7127402
22 January 2020 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6894276
5 December 2019 Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6867792
18 September 2019 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814773
3 December 2018 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6591516
21 February 2018 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6359010
16 November 2017 Hull Examination · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6308148
12 April 2017 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6123189
7 February 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6084222
5 January 2017 Deficiency Check · DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6066330
8 February 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5811654

Deficiency record · 31

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 30 January 2026 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following. MI observed cracked stitch weld in the portside forward crash compartment pontoon, the most upper stitch weld on the first baffle, provide repair proposal for MI review.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 March 2026
Resolved 10 March 2026
Resolution: Recieved evidence of completed repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 4 February 2025 Resolved
A hatch exposed to the weatherdeck must be watertight. MI observed scuttle gasket leading to port/stbd anchor locker and fwd centerline compartment in need of replacement due to being flat and lo longer providing adequate seal. 46 CFR 179.360
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 April 2025
Resolved 31 March 2025
Resolution: Vessel replaced gaskets on all flush mounted scuttles.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Breaker box in engine room had missing breaker or knockout on panel. Install/replace blank cover over missing breaker.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 11 March 2022
Resolution: Tech repair report and photos provided documenting repairs made. Blanks installed covering missing breakers.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 24 February 2022 Resolved
The use of twist-on type wire nuts is permitted as long as connections are made within an enclosure. Power cable wiring for fire pump found outside junction box and reduced in wire size to accommodate installation. Provide evidence the wire size can be reduced from current size cable to smaller size wiring used for fire pump size and type. Any open wiring needs to be installed in a junction box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 March 2022
Resolved 11 March 2022
Resolution: Tech repair report and photos provided documenting repairs made. Terminated wires inside junction box.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 January 2021 Resolved
Vessel was missing IBA. O/O indicated that it's currently at licensed CG repair facility for yearly servicing. Vessels operating on oceans route must have IBA for 67% of total number of persons onboard. 46CFR180.202(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2021
Resolved 29 January 2021
Resolution: Conducted virtual exam to clear all deficiencies to satisfaction of MI
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 January 2021 Resolved
Fire hose with nozzle must be attached to each hydrant at all times. Hose was missing do to inoperable test conducted on 19Jan2021. Replace to satisfaction of MI. 46CFR181.320(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 January 2021
Resolution: Conducted virtual exam to clear all deficiencies to satisfaction of MI
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 21 February 2018 Resolved
EACH GENERATOR MUST BE PROTECTED BY AN OVERCURRENT DEVICE SET VALUE NOT EXCEEDING 115% OF THE GENERATOR FULL LOAD RATING.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2018
Resolved 10 May 2018
Resolution: Breakers replaced with 150A: ALL SAT
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 27 January 2017 Resolved
24. Provide a complete listing of both the lower deck and upper deck hydraulic winch installation including all cabling, accessory gear placed on board (such as block and tackle, gear being towed, etc). Provide foundation installation drawings. Provide electrical line diagrams including cable length and size, amperage draw, breakers installed, etc. Provide...see narrative for remaining def.
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 8 January 2018
Resolution: The expectation that is an evaluation will be made by MSC on whether or not it needs to undergo a deadweight survey or a full stability test following the change to the lightship characteristics. See Activity #6326999
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 25 January 2017 Resolved
1. Vessel’s COI is for 44 persons on an oceans voyage. However, vessel is only provided with two 12 person life rafts for a total lifesaving of 24 persons. Vessel is limited to carrying not more than 24 total persons on board while operating more than 3 nautical miles from shore until additional survival craft are obtained in accordance with 46 CFR 180.202.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 16 March 2017
Resolution: Vessel added 20 person IBA, installed sat.
Operations/Management › Drug and Alcohol Testing › Testing, Random
Issued 25 January 2017 Resolved
2. Company is conducting drug testing one month per year, which is not considered random. Company must conduct random testing throughout the year in accordance 46 CFR 16.230.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 25 January 2017 Resolved
3. Provide a copy of MIS Report Confirmation of Filing Certificate for calendar year 2016 in accordance with 46 CFR 16.500
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 25 January 2017 Resolved
4. Provide documentation that all supervisory personnel have received appropriate one hour of training per 46 CFR 16.401 (b).
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 January 2017 Resolved
5. Provide approved alcohol testing devices in accordance with 46 CFR 4.06. Testing devices must be approved by the National Highway Traffic Safety Administration.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 16 March 2017
Resolution: Vessel provided brethalizer and Captain read operation instructions.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 25 January 2017 Resolved
6. Repair HF radio antenna connection and post appropriate emergency radio frequencies in accordance with 47 CFR 80.1089.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Documentation › Certificates/Documents › FCC SSL
Issued 25 January 2017 Resolved
7. Provide an FCC station license per 47 CFR 80.401.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 25 January 2017 Resolved
8. Provide an FCC radio safety certificate per 47 CFR 80.401
Action required: 705 - Other - as specified
Due 25 January 2017
Resolved 15 February 2017
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 25 January 2017 Resolved
9. Post the vessels COI and Stability letter so that all pages are visible in accordance with 46 CFR 176.302 and 176.306.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Navigation › Piloting/Steering › Marine Charts
Issued 25 January 2017 Resolved
10. Provide appropriate charts for all areas the vessel operates in accordance with 46 CFR 184.420
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 February 2017
Resolved 15 February 2017
Stability › Watertight Integrity › General
Issued 25 January 2017 Resolved
11. Vessel has sluice valves installed for draining water from the area forward of the collision bulkhead to the sewage/water tank compartments. As sluice valves are not permitted in watertight bulkheads, the piping and valve must be permanently removed in accordance with 46 CFR 179.320.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 March 2017
Resolved 12 April 2017
Resolution: Verified that sluice valves were properly capped in the area forward of the collision bulkhead.
Engineering › Bilge Water Management System › Pump
Issued 25 January 2017 Resolved
12. Provide a portable bilge pump capable of pumping water from any compartment overboard in accordance with 46CFR182.25-10(e).
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Operations/Management › Drills/Instruction › Fire
Issued 25 January 2017 Resolved
13.Conduct quarterly fire drills in accordance with 46 CFR 185.420
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Operations/Management › Drills/Instruction › Abandon Ship
Issued 25 January 2017 Resolved
14.Conduct quarterly abandon ship drills in accordance with 46 CFR 185.520.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Operations/Management › Vessel Safety Management › Plans for Shipboard Operations
Issued 25 January 2017 Resolved
15.Post the emergency instruction at the operating station in accordance with 46 CFR 185.510
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Fire Fighting › Fire Pumps › Bearings
Issued 25 January 2017 Resolved
16.Vessel must have an operable fire pump prior to carrying passengers in accordance with 46 CFR 181.300.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2017
Resolved 12 April 2017
Resolution: Verified that the vessel has an operable fire pump.
Lifesaving › Visual Distress Signals (General) › Not on Board
Issued 25 January 2017 Resolved
17.Provide two additional hand red flares approved under series 160.021 in accordance with 46 CFR 180.68.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Communications › Internal Communications System › Sound-powered Telephone
Issued 25 January 2017 Resolved
18. Vessel must have a public address system capable of broadcasting to all accommodation spaces simultaneously in accordance with 46 CFR 184.610.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Stability › Watertight Integrity › General
Issued 25 January 2017 Resolved
19. Provide securing devices for the forward three hatches to prevent their loss in accordance with 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 25 January 2017 Resolved
20. Provide 5 child life jackets in accordance with 46 CFR 180.71.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 25 January 2017 Resolved
21. The ring life buoy floating water light must be attached with a lanyard and clip in accordance with 46 CFR 180.70.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 January 2017 Resolved
22. Provide chafing material to prevent further damage to the hydraulic hoses located in the overhead on the main deck in accordance with 46 CFR 176.830.
Action required: 705 - Other - as specified
Due 15 February 2017
Resolved 15 February 2017
Construction/Loadline › Hull › Weld
Issued 25 January 2017 Resolved
23. Repair cracked welds in the port sewage tank space on frames 3, 4 and 5, and repair crack in the water tank space on frame 3 in accordance with 46 CFR 176.830.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 March 2017
Resolved 16 March 2017
Resolution: Welded all cracks.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.