← All vessels
SEAWAYS WHEAT
SEAWAYS WHEAT is a 2015 tank ship. The Coast Guard has recorded 30 inspections since 2016, most recently in December 2025, along with 9 deficiencies and 2 operational controls.
Records from 2016 to 2025. Most recent: inspection, 6 December 2025.
- Built
- 2015
- Last inspected
- 6 December 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 9 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9681168 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7KN4
1328747
Flag
MARSHALL ISLANDS
—
Maury page id
psix-1328747
Inspections, by type
…with no type recorded5
Years with a record
10 calendar years (2016–2025)
The 30 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it60958 - Displacement, Metric Ton
49990 - Dead Weight, Metric Ton
29767 - Convention (Subpart B), Gross Ton
13823 - Convention (Subpart B), Net Ton
49990 - Dead Weight, Metric Ton
29767 - Convention (Subpart B), Gross Ton
13823 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 30
6 December 2025
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8278449
26 July 2025
PSC B · Administrative Inspection · COC-CHEM & TVE Renew · COE-Administrative · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8191649
5 November 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8030002
19 September 2024
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8005908
17 August 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7983192
3 August 2024
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7973420
21 July 2024
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7961062
7 June 2023
COC-CHEM & TVE Renew
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7701807
20 October 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7581200
6 June 2022
PSC B · COC-CHEM & TVE Annual
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7459818
27 May 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7460647
26 May 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7460072
2 June 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7212979
31 May 2021
COC-CHEM & TVE Renew · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7210171
23 June 2020
COC-CHEM & TVE Annual · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6978176
17 November 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6856984
17 November 2019
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6857221
16 November 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6856937
16 May 2019
COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6682864
12 April 2019
Ballast Water Examination
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6659757
19 June 2018
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6450252
2 June 2018
ISPS II Exam · COC-CHEM & TVE Annual · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6427274
31 May 2018
Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6430814
27 March 2018
Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6378600
20 November 2017
Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6310011
13 May 2017
ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6142558
12 January 2017
ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6067425
19 November 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6044273
1 April 2016
COC-CHEM & TVE Annual · Ballast Water Examination · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5844605
5 February 2016
ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5806057
Deficiency record · 9
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 19 September 2024
Resolved
THE MASTER, OWNER, OPERATOR, AGENT OR PERSON IN CHARGE OF VESSELS EMPLOYING A COAST GUARD APPROVED BWMS MUST MMET THE APPLICABLE BALLAST WATER DISCHARGE STANDARDS (BWDS). VESSEL SELF-REPORTED MALFUNCTIONING BWMS AND WAS UNABLE TO REPAIR IN PORT DUE TO UNAVAILABILITY OF SPARES. FLAG AND CLASS NOTIFIED.
33CFR 151.2025(a)(1)
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 31 May 2021
Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency, due regard being paid to such services as may have to be operated simultaneously. Vessel reported automatic voltage regulator on emergency generator switchboard inoperable. PSCO observed emergency generator unable to start automatically and unable to hold a load. In an emergency, vessel's emergency generator is inoperable, statement confirmed by captain and chief engineer.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 23 June 2020
Resolved
Following installation, the master, owner, operator, agent, or person in charge ofthe vessel subject to this subpart must perptly maintain the BWMS in accordance with all manufacturer specifications. Vessel reported BWMS inoperable. Vessel requested 3 month extension to previously issued flag state dispensation to expire on 30SEP2020 due to unavailability of technicians and parts at upcoming ports of call. AFter cargo dischage in LA-LB, vessel will load ballast and depart for South Korea.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 12 April 2019
Resolved
To discharge ballast water into the waters of the United States, the master, owner, operator, agent or person in charge of a vessel subject to 151.2025 of this
subpart must either ensure that the ballast water meets the ballast water discharge standard in 151.2030(a), use an AMS as described in 151.2025(a)(3), or ballast
with water from a U.S. public water system, according to the schedule in paragraph (b) of this section.
Subject vessel, of keel laid date 11SEP2014 and ballast water capacity of 23142 m3, is past its compliance date per the implementation schedule in 33 CFR
151.2035 (b). Currently, vessel’s installed BWTS is inoperative.
Vessel is not authorized to discharge untreated ballast into the waters of the U.S. without prior written authorization from the local Captain of the Port under the
provisions of 33 CFR 151.2040 (b).
Lifesaving › Lifeboat Equipment › Food Ration
Issued 2 June 2018
Resolved
Rations shall be kept in airtight packaging and be stowed in a watertight container. All lifesaving and arrangements shall comply with the applicable requirements of the Code. Food rations were not airtight.
Operations/Management › Ballast Water Managment › Ballast Water Discharge
Issued 20 November 2017
Resolved
Vessels employing a Coast Guard-approved ballast water management system must meet the applicable ballast water discharge standard (BWDS) found in 33 CFR 151.2030 at all times of discharge into waters of the United States. NBIC reports indicate untreated ballast water was discharged into United States waters by the BERYL in the ports of Port Arthur, TX (06MAR2017), New Orleans, LA (22MAR2017), and Corpus Christi, TX (01JUN2017).
Operations/Management › Ballast Water Managment › Submission of Report
Issued 20 November 2017
Resolved
If the installed ballast water management system required by 33 CFR 151, Subpart D stops operating properly during a voyage, or the vessel’s ballast water management method is unexpectedly unavailable, the person directing the movement of the vessel must ensure that the problem is reported to the nearest Captain of the Port (COTP) or District Commander as soon as practicable. The BERYL failed to report any issues with the operation or availability of their installed ballast water management system in the ports listed above.
Electrical › Electric Generation Source (emergency) › Number of Sources
Issued 1 April 2016
Resolved
1499-Other Prop & Aux- Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by Admin. A 2nd source of energy shall be provided unless manual starting can be demonstrated to be effective. PSCO observed that the emergency generator's secondary means of start was not operational. 74SOLAS(14)II-1/44.2
Construction/Loadline › Markings › Load Line Mark
Issued 1 April 2016
Resolved
1299-Other Loadlines- Details of loadline markings. The rings, lines, and letters shall be painted in white or yellow on a dark background. The marks shall be plainly visible and, if necessary, special arrangements shall be made for this purpose. PSCO observed that both port and starboard loadlines were not in a color contrasting to the hull. 66 ICLL I/8
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.